Quantitative analysis of performance of a hydrogen peroxide-based glucose biosensor

A partial glucose biosensor was constructed using a selective internal layer, an enzyme layer and a gold electrode. Both membrane layers are based on cross-linked polyvinyl alcohol (PVA). The performance of the partial glucose biosensor was analyzed particularly with respect to the interfering effec...

Full description

Bibliographic Details
Main Author: Abd. Aziz, Azila
Format: Article
Language:English
Published: Penerbit UTM Press 2009
Subjects:
Online Access:http://eprints.utm.my/9996/
http://eprints.utm.my/9996/1/UTMjurnalTEK_51F_DIS%5B08%5D.pdf
_version_ 1848891991983652864
author Abd. Aziz, Azila
author_facet Abd. Aziz, Azila
author_sort Abd. Aziz, Azila
building UTeM Institutional Repository
collection Online Access
description A partial glucose biosensor was constructed using a selective internal layer, an enzyme layer and a gold electrode. Both membrane layers are based on cross-linked polyvinyl alcohol (PVA). The performance of the partial glucose biosensor was analyzed particularly with respect to the interfering effects of acetaminophen, a non-ionic molecule. The sensitivity of the immobilized enzyme to glucose was high but it was not high enough to counter acetaminophen interference. The addition of the moderately selective PVA internal layer did not seem to have a significant effect on interference. A mathematical model was then used to analyze the performance of a completed biosensor. A simulated external layer was added to the two layers. The mathematical model predicted that the addition of an external layer with lowered permeability to solutes could improve the performance of the sensor.
first_indexed 2025-11-15T21:06:46Z
format Article
id utm-9996
institution Universiti Teknologi Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T21:06:46Z
publishDate 2009
publisher Penerbit UTM Press
recordtype eprints
repository_type Digital Repository
spelling utm-99962010-07-22T02:03:27Z http://eprints.utm.my/9996/ Quantitative analysis of performance of a hydrogen peroxide-based glucose biosensor Abd. Aziz, Azila TP Chemical technology A partial glucose biosensor was constructed using a selective internal layer, an enzyme layer and a gold electrode. Both membrane layers are based on cross-linked polyvinyl alcohol (PVA). The performance of the partial glucose biosensor was analyzed particularly with respect to the interfering effects of acetaminophen, a non-ionic molecule. The sensitivity of the immobilized enzyme to glucose was high but it was not high enough to counter acetaminophen interference. The addition of the moderately selective PVA internal layer did not seem to have a significant effect on interference. A mathematical model was then used to analyze the performance of a completed biosensor. A simulated external layer was added to the two layers. The mathematical model predicted that the addition of an external layer with lowered permeability to solutes could improve the performance of the sensor. Penerbit UTM Press 2009-12 Article PeerReviewed application/pdf en http://eprints.utm.my/9996/1/UTMjurnalTEK_51F_DIS%5B08%5D.pdf Abd. Aziz, Azila (2009) Quantitative analysis of performance of a hydrogen peroxide-based glucose biosensor. Jurnal Teknologi (Kejuruteraan) (51F). pp. 96-106. ISSN 0127-9696 http://www.penerbit.utm.my/onlinejournal/51/F/51sirif08.pdf
spellingShingle TP Chemical technology
Abd. Aziz, Azila
Quantitative analysis of performance of a hydrogen peroxide-based glucose biosensor
title Quantitative analysis of performance of a hydrogen peroxide-based glucose biosensor
title_full Quantitative analysis of performance of a hydrogen peroxide-based glucose biosensor
title_fullStr Quantitative analysis of performance of a hydrogen peroxide-based glucose biosensor
title_full_unstemmed Quantitative analysis of performance of a hydrogen peroxide-based glucose biosensor
title_short Quantitative analysis of performance of a hydrogen peroxide-based glucose biosensor
title_sort quantitative analysis of performance of a hydrogen peroxide-based glucose biosensor
topic TP Chemical technology
url http://eprints.utm.my/9996/
http://eprints.utm.my/9996/
http://eprints.utm.my/9996/1/UTMjurnalTEK_51F_DIS%5B08%5D.pdf