Lokasi Pengesan Dan Sudut Penghadang Optimum Untuk Tomografi Kemuatan Elektrik Bagi Penganggaran Ketinggian Minyak

Electric capacitance tomography (ECT) is one of the branches of process tomography that applied in imaging sector. ECT is one of the techniques to measure the internal spatial of materials. Artificial Neural Network (ANN) is an electronic model that designed from human brain to process informa...

Full description

Bibliographic Details
Main Author: Ibrahim, Ahmad Kamal
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2006
Subjects:
Online Access:http://eprints.usm.my/58735/
http://eprints.usm.my/58735/1/Lokasi%20Pengesan%20Dan%20Sudut%20Penghadang%20Optimum%20Untuk%20Tomografi%20Kemuatan%20Elektrik%20Bagi%20Penganggaran%20Ketinggian%20Minyak_Ahmad%20Kamal%20Ibrahim.pdf
_version_ 1848883979245060096
author Ibrahim, Ahmad Kamal
author_facet Ibrahim, Ahmad Kamal
author_sort Ibrahim, Ahmad Kamal
building USM Institutional Repository
collection Online Access
description Electric capacitance tomography (ECT) is one of the branches of process tomography that applied in imaging sector. ECT is one of the techniques to measure the internal spatial of materials. Artificial Neural Network (ANN) is an electronic model that designed from human brain to process information that use learning algorithm. ECT is a process that uses capacitance for determine of certain values. There are two types of tomography systems; one is medical tomography and process tomography. The importance of this research is to determine the pipe thickness, R2 and the of electrode guard angle, βº. This process done is to get the optimum parameter which is the lowest mean of absolute error. Matlab is used to generate raw ECT dataset with using an ECT simulator.
first_indexed 2025-11-15T18:59:24Z
format Monograph
id usm-58735
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:59:24Z
publishDate 2006
publisher Universiti Sains Malaysia
recordtype eprints
repository_type Digital Repository
spelling usm-587352023-05-30T08:20:23Z http://eprints.usm.my/58735/ Lokasi Pengesan Dan Sudut Penghadang Optimum Untuk Tomografi Kemuatan Elektrik Bagi Penganggaran Ketinggian Minyak Ibrahim, Ahmad Kamal T Technology TK Electrical Engineering. Electronics. Nuclear Engineering Electric capacitance tomography (ECT) is one of the branches of process tomography that applied in imaging sector. ECT is one of the techniques to measure the internal spatial of materials. Artificial Neural Network (ANN) is an electronic model that designed from human brain to process information that use learning algorithm. ECT is a process that uses capacitance for determine of certain values. There are two types of tomography systems; one is medical tomography and process tomography. The importance of this research is to determine the pipe thickness, R2 and the of electrode guard angle, βº. This process done is to get the optimum parameter which is the lowest mean of absolute error. Matlab is used to generate raw ECT dataset with using an ECT simulator. Universiti Sains Malaysia 2006-05-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/58735/1/Lokasi%20Pengesan%20Dan%20Sudut%20Penghadang%20Optimum%20Untuk%20Tomografi%20Kemuatan%20Elektrik%20Bagi%20Penganggaran%20Ketinggian%20Minyak_Ahmad%20Kamal%20Ibrahim.pdf Ibrahim, Ahmad Kamal (2006) Lokasi Pengesan Dan Sudut Penghadang Optimum Untuk Tomografi Kemuatan Elektrik Bagi Penganggaran Ketinggian Minyak. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Elektrik dan Elektronik. (Submitted)
spellingShingle T Technology
TK Electrical Engineering. Electronics. Nuclear Engineering
Ibrahim, Ahmad Kamal
Lokasi Pengesan Dan Sudut Penghadang Optimum Untuk Tomografi Kemuatan Elektrik Bagi Penganggaran Ketinggian Minyak
title Lokasi Pengesan Dan Sudut Penghadang Optimum Untuk Tomografi Kemuatan Elektrik Bagi Penganggaran Ketinggian Minyak
title_full Lokasi Pengesan Dan Sudut Penghadang Optimum Untuk Tomografi Kemuatan Elektrik Bagi Penganggaran Ketinggian Minyak
title_fullStr Lokasi Pengesan Dan Sudut Penghadang Optimum Untuk Tomografi Kemuatan Elektrik Bagi Penganggaran Ketinggian Minyak
title_full_unstemmed Lokasi Pengesan Dan Sudut Penghadang Optimum Untuk Tomografi Kemuatan Elektrik Bagi Penganggaran Ketinggian Minyak
title_short Lokasi Pengesan Dan Sudut Penghadang Optimum Untuk Tomografi Kemuatan Elektrik Bagi Penganggaran Ketinggian Minyak
title_sort lokasi pengesan dan sudut penghadang optimum untuk tomografi kemuatan elektrik bagi penganggaran ketinggian minyak
topic T Technology
TK Electrical Engineering. Electronics. Nuclear Engineering
url http://eprints.usm.my/58735/
http://eprints.usm.my/58735/1/Lokasi%20Pengesan%20Dan%20Sudut%20Penghadang%20Optimum%20Untuk%20Tomografi%20Kemuatan%20Elektrik%20Bagi%20Penganggaran%20Ketinggian%20Minyak_Ahmad%20Kamal%20Ibrahim.pdf