Estimation of radiation exposure to personnel in nuclear medicine during 131| ablation procedure: comparison between direct and indirect methods

This study focused on measurement of exposure rates to personnel in Nuclear Medicine during 131l ablation procedures using direct and indirect methods. 9 patients undergoing 131l ablation procedures with average activity 131.11 mCi were randomly selected in this study. The direct method of exposure...

Full description

Bibliographic Details
Main Author: Mohamad, Nurul Ashikin
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2015
Subjects:
Online Access:http://eprints.usm.my/58219/
http://eprints.usm.my/58219/1/NURUL%20ASHIKIN%20BINTI%20MOHAMAD%20-%20e.pdf
_version_ 1848883839825346560
author Mohamad, Nurul Ashikin
author_facet Mohamad, Nurul Ashikin
author_sort Mohamad, Nurul Ashikin
building USM Institutional Repository
collection Online Access
description This study focused on measurement of exposure rates to personnel in Nuclear Medicine during 131l ablation procedures using direct and indirect methods. 9 patients undergoing 131l ablation procedures with average activity 131.11 mCi were randomly selected in this study. The direct method of exposure rate measurement was conducted using survey meter (Victoreen 415P-RYR) at various distances (1.0 m, 1.5 m and 2.0 m) from the patients at thyroid and abdomen region. The indirect method of exposure rate measurement was conducted using mathematical model of exposure rate. The result showed that exposure rates decreased with the increased in distance for both direct and indirect methods. The exposure rate of thyroid and abdomen for direct method was higher than indirect method at all distances. The percentage difference between direct and indirect method for various distance were 22.39% ± 2.04 (1.0 m), 16.37% ± 1.38 (1.5 m) and 34.04% ± 3.64 (2.0 m) respectively. Percentage difference of low activity (80 mCi) was significantly decreased with increased time while the percentage difference in medium (120 mCi) and high activity (175 mCi) were significantly decreased as the time increased. The exposure rate between thyroid and abdomen increased at higher 5.32% ± 0.284 (120 mCi), 11.67% ± 0.345 (175 mCi). As conclusion, this study provides useful indicator of occupational exposure to personnel that can be used as guidance for personnel attending patients in radioiodine wards.
first_indexed 2025-11-15T18:57:11Z
format Monograph
id usm-58219
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:57:11Z
publishDate 2015
publisher Universiti Sains Malaysia
recordtype eprints
repository_type Digital Repository
spelling usm-582192023-05-07T01:31:28Z http://eprints.usm.my/58219/ Estimation of radiation exposure to personnel in nuclear medicine during 131| ablation procedure: comparison between direct and indirect methods Mohamad, Nurul Ashikin QC Physics This study focused on measurement of exposure rates to personnel in Nuclear Medicine during 131l ablation procedures using direct and indirect methods. 9 patients undergoing 131l ablation procedures with average activity 131.11 mCi were randomly selected in this study. The direct method of exposure rate measurement was conducted using survey meter (Victoreen 415P-RYR) at various distances (1.0 m, 1.5 m and 2.0 m) from the patients at thyroid and abdomen region. The indirect method of exposure rate measurement was conducted using mathematical model of exposure rate. The result showed that exposure rates decreased with the increased in distance for both direct and indirect methods. The exposure rate of thyroid and abdomen for direct method was higher than indirect method at all distances. The percentage difference between direct and indirect method for various distance were 22.39% ± 2.04 (1.0 m), 16.37% ± 1.38 (1.5 m) and 34.04% ± 3.64 (2.0 m) respectively. Percentage difference of low activity (80 mCi) was significantly decreased with increased time while the percentage difference in medium (120 mCi) and high activity (175 mCi) were significantly decreased as the time increased. The exposure rate between thyroid and abdomen increased at higher 5.32% ± 0.284 (120 mCi), 11.67% ± 0.345 (175 mCi). As conclusion, this study provides useful indicator of occupational exposure to personnel that can be used as guidance for personnel attending patients in radioiodine wards. Universiti Sains Malaysia 2015 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/58219/1/NURUL%20ASHIKIN%20BINTI%20MOHAMAD%20-%20e.pdf Mohamad, Nurul Ashikin (2015) Estimation of radiation exposure to personnel in nuclear medicine during 131| ablation procedure: comparison between direct and indirect methods. Project Report. Universiti Sains Malaysia. (Submitted)
spellingShingle QC Physics
Mohamad, Nurul Ashikin
Estimation of radiation exposure to personnel in nuclear medicine during 131| ablation procedure: comparison between direct and indirect methods
title Estimation of radiation exposure to personnel in nuclear medicine during 131| ablation procedure: comparison between direct and indirect methods
title_full Estimation of radiation exposure to personnel in nuclear medicine during 131| ablation procedure: comparison between direct and indirect methods
title_fullStr Estimation of radiation exposure to personnel in nuclear medicine during 131| ablation procedure: comparison between direct and indirect methods
title_full_unstemmed Estimation of radiation exposure to personnel in nuclear medicine during 131| ablation procedure: comparison between direct and indirect methods
title_short Estimation of radiation exposure to personnel in nuclear medicine during 131| ablation procedure: comparison between direct and indirect methods
title_sort estimation of radiation exposure to personnel in nuclear medicine during 131| ablation procedure: comparison between direct and indirect methods
topic QC Physics
url http://eprints.usm.my/58219/
http://eprints.usm.my/58219/1/NURUL%20ASHIKIN%20BINTI%20MOHAMAD%20-%20e.pdf