Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging

Phantom studies are an important part in medical imaging as it can evaluate the performance and quality assurance (QA) test of dual-modality PET/CT. The purpose of this study is to, design, fabricate and develop a multipurpose smart phantom which includes the internal structures, water, human tis...

Full description

Bibliographic Details
Main Author: Zainon, Rafidah
Format: Thesis
Language:English
Published: 2008
Subjects:
Online Access:http://eprints.usm.my/31141/
http://eprints.usm.my/31141/1/RAFIDAH_BINTI_ZAINON.pdf
_version_ 1848876488660615168
author Zainon, Rafidah
author_facet Zainon, Rafidah
author_sort Zainon, Rafidah
building USM Institutional Repository
collection Online Access
description Phantom studies are an important part in medical imaging as it can evaluate the performance and quality assurance (QA) test of dual-modality PET/CT. The purpose of this study is to, design, fabricate and develop a multipurpose smart phantom which includes the internal structures, water, human tissue equivalent materials and radioactive source for dual-modality Positron Emission Tomography/Computed Tomography (PET/CT) imaging. In this study, experimental determination of Hounsfield units (HU), mass attenuation coefficient, elemental composition analysis and structure analysis were performed on phantom materials using PET/CT scanner, Multichannel Analyser (MCA), CI-INS analyser and Scanning Electron MicroscopelEnergy Dispersive X-Ray (SEMlEDX) respectively. Kajian fantom adalah bahagian yang penting dalam pengimejan perubatan kerana ia dapat menilai pedaksanaan dan ujian jaminan kualiti (QA) dwi-modaliti Tomografi Pancaran Positronffomografi Berkomputer {PETtCT). Tujuan kajian ini adalah untuk merekabentuk, memfabrikasi dan membangunkan fantom pintar pelbagai tujuan yang termasuk struktur dalaman, air, bahan-bahan setara dengan tisu manusia dan sumber radioaktif untuk pengimejan dwi-modaliti PETtCT. Dalam kajian ini, penentuan secara eksperimen Unit Hounsfield (HU), pekali atenuasi jisim, analisis komposisi elemen dan analisis struktur telah dilakukan terhadap bahan-bahan fantom menggunakan PETtCT skan, Penganalisis Berbilang Saluran (MCA), Penganalis CHNS dan Pengimbas -Mikroskop ElektronIKeselerakan Tenaga X-ray (SEMlEDX) masing-masing.
first_indexed 2025-11-15T17:00:21Z
format Thesis
id usm-31141
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T17:00:21Z
publishDate 2008
recordtype eprints
repository_type Digital Repository
spelling usm-311412017-12-11T03:48:50Z http://eprints.usm.my/31141/ Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging Zainon, Rafidah QC1 Physics (General) Phantom studies are an important part in medical imaging as it can evaluate the performance and quality assurance (QA) test of dual-modality PET/CT. The purpose of this study is to, design, fabricate and develop a multipurpose smart phantom which includes the internal structures, water, human tissue equivalent materials and radioactive source for dual-modality Positron Emission Tomography/Computed Tomography (PET/CT) imaging. In this study, experimental determination of Hounsfield units (HU), mass attenuation coefficient, elemental composition analysis and structure analysis were performed on phantom materials using PET/CT scanner, Multichannel Analyser (MCA), CI-INS analyser and Scanning Electron MicroscopelEnergy Dispersive X-Ray (SEMlEDX) respectively. Kajian fantom adalah bahagian yang penting dalam pengimejan perubatan kerana ia dapat menilai pedaksanaan dan ujian jaminan kualiti (QA) dwi-modaliti Tomografi Pancaran Positronffomografi Berkomputer {PETtCT). Tujuan kajian ini adalah untuk merekabentuk, memfabrikasi dan membangunkan fantom pintar pelbagai tujuan yang termasuk struktur dalaman, air, bahan-bahan setara dengan tisu manusia dan sumber radioaktif untuk pengimejan dwi-modaliti PETtCT. Dalam kajian ini, penentuan secara eksperimen Unit Hounsfield (HU), pekali atenuasi jisim, analisis komposisi elemen dan analisis struktur telah dilakukan terhadap bahan-bahan fantom menggunakan PETtCT skan, Penganalisis Berbilang Saluran (MCA), Penganalis CHNS dan Pengimbas -Mikroskop ElektronIKeselerakan Tenaga X-ray (SEMlEDX) masing-masing. 2008-08 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/31141/1/RAFIDAH_BINTI_ZAINON.pdf Zainon, Rafidah (2008) Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging. Masters thesis, Universiti Sains Malaysia.
spellingShingle QC1 Physics (General)
Zainon, Rafidah
Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
title Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
title_full Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
title_fullStr Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
title_full_unstemmed Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
title_short Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
title_sort design and fabrication of multipurpose smart phantom for positron emission tomography/computed tomography imaging
topic QC1 Physics (General)
url http://eprints.usm.my/31141/
http://eprints.usm.my/31141/1/RAFIDAH_BINTI_ZAINON.pdf