Dual-fuzzy MPPT in photovoltaic-DC analysis for dual-load operation with SEPIC converter

In this paper, dual-fuzzy based maximum power point tracking (MPPT) is proposed for standalone photovoltaic (PV) system, working for dual-load operation. The proposed MPPT consists of two different fuzzy logic controllers (FLCs) to support operation of single ended primary-inductor converter (SEPIC)...

Full description

Bibliographic Details
Main Authors: Ramalu, Tanaselan, Mohd Radzi, Mohd Amran, Mohd Zainuri, Muhammad Ammirrul Atiqi, Abdul Wahab, Noor Izzri, Abdul Rahman, Ribhan Zafira
Format: Article
Language:English
Published: United Kingdom Simulation Society 2016
Online Access:http://psasir.upm.edu.my/id/eprint/55958/
http://psasir.upm.edu.my/id/eprint/55958/1/Dual-fuzzy%20MPPT%20in%20photovoltaic-DC%20analysis%20for%20dual-load%20operation%20with%20SEPIC%20converter.pdf
_version_ 1848852947426869248
author Ramalu, Tanaselan
Mohd Radzi, Mohd Amran
Mohd Zainuri, Muhammad Ammirrul Atiqi
Abdul Wahab, Noor Izzri
Abdul Rahman, Ribhan Zafira
author_facet Ramalu, Tanaselan
Mohd Radzi, Mohd Amran
Mohd Zainuri, Muhammad Ammirrul Atiqi
Abdul Wahab, Noor Izzri
Abdul Rahman, Ribhan Zafira
author_sort Ramalu, Tanaselan
building UPM Institutional Repository
collection Online Access
description In this paper, dual-fuzzy based maximum power point tracking (MPPT) is proposed for standalone photovoltaic (PV) system, working for dual-load operation. The proposed MPPT consists of two different fuzzy logic controllers (FLCs) to support operation of single ended primary-inductor converter (SEPIC) in buck and boost conditions, by depending on irradiance conditions. To realize dual-operation of SEPIC, dual-load approach has been applied by selecting suitable load resistance, which could achieve maximum power point (MPP) with specific irradiance and duty cycle. Then, relationship between irradiance, load resistance and duty cycle has been discussed in details. The dual-fuzzy based MPPT together with PV module of Kyocera KD210GH-2PU connected to SEPIC was simulated in MATLAB-Simulink, and further the laboratory prototype with TMS320F28335 eZdsp board was implemented. Each load was connected to direct current (DC) supply to ensure continuity of the supply to both loads. Both simulation and experimental results and comparison analysis (with P&O) have been presented. From the results and analysis, dual-fuzzy based MPPT with dual loads shows that by switching from PV to DC, there is no change in output voltage, but during the switching from DC to PV, there are significant changes that can be noticed according to the irradiances.
first_indexed 2025-11-15T10:46:10Z
format Article
id upm-55958
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T10:46:10Z
publishDate 2016
publisher United Kingdom Simulation Society
recordtype eprints
repository_type Digital Repository
spelling upm-559582017-06-30T09:57:02Z http://psasir.upm.edu.my/id/eprint/55958/ Dual-fuzzy MPPT in photovoltaic-DC analysis for dual-load operation with SEPIC converter Ramalu, Tanaselan Mohd Radzi, Mohd Amran Mohd Zainuri, Muhammad Ammirrul Atiqi Abdul Wahab, Noor Izzri Abdul Rahman, Ribhan Zafira In this paper, dual-fuzzy based maximum power point tracking (MPPT) is proposed for standalone photovoltaic (PV) system, working for dual-load operation. The proposed MPPT consists of two different fuzzy logic controllers (FLCs) to support operation of single ended primary-inductor converter (SEPIC) in buck and boost conditions, by depending on irradiance conditions. To realize dual-operation of SEPIC, dual-load approach has been applied by selecting suitable load resistance, which could achieve maximum power point (MPP) with specific irradiance and duty cycle. Then, relationship between irradiance, load resistance and duty cycle has been discussed in details. The dual-fuzzy based MPPT together with PV module of Kyocera KD210GH-2PU connected to SEPIC was simulated in MATLAB-Simulink, and further the laboratory prototype with TMS320F28335 eZdsp board was implemented. Each load was connected to direct current (DC) supply to ensure continuity of the supply to both loads. Both simulation and experimental results and comparison analysis (with P&O) have been presented. From the results and analysis, dual-fuzzy based MPPT with dual loads shows that by switching from PV to DC, there is no change in output voltage, but during the switching from DC to PV, there are significant changes that can be noticed according to the irradiances. United Kingdom Simulation Society 2016 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/55958/1/Dual-fuzzy%20MPPT%20in%20photovoltaic-DC%20analysis%20for%20dual-load%20operation%20with%20SEPIC%20converter.pdf Ramalu, Tanaselan and Mohd Radzi, Mohd Amran and Mohd Zainuri, Muhammad Ammirrul Atiqi and Abdul Wahab, Noor Izzri and Abdul Rahman, Ribhan Zafira (2016) Dual-fuzzy MPPT in photovoltaic-DC analysis for dual-load operation with SEPIC converter. International Journal of Simulation: Systems, Science & Technology, 17 (41). 46.1-46.6. ISSN 1473-8031; ESSN: 1473-804X http://ijssst.info/Vol-17/No-41/cover-17-41.htm 10.5013/IJSSST.a.17.41.46
spellingShingle Ramalu, Tanaselan
Mohd Radzi, Mohd Amran
Mohd Zainuri, Muhammad Ammirrul Atiqi
Abdul Wahab, Noor Izzri
Abdul Rahman, Ribhan Zafira
Dual-fuzzy MPPT in photovoltaic-DC analysis for dual-load operation with SEPIC converter
title Dual-fuzzy MPPT in photovoltaic-DC analysis for dual-load operation with SEPIC converter
title_full Dual-fuzzy MPPT in photovoltaic-DC analysis for dual-load operation with SEPIC converter
title_fullStr Dual-fuzzy MPPT in photovoltaic-DC analysis for dual-load operation with SEPIC converter
title_full_unstemmed Dual-fuzzy MPPT in photovoltaic-DC analysis for dual-load operation with SEPIC converter
title_short Dual-fuzzy MPPT in photovoltaic-DC analysis for dual-load operation with SEPIC converter
title_sort dual-fuzzy mppt in photovoltaic-dc analysis for dual-load operation with sepic converter
url http://psasir.upm.edu.my/id/eprint/55958/
http://psasir.upm.edu.my/id/eprint/55958/
http://psasir.upm.edu.my/id/eprint/55958/
http://psasir.upm.edu.my/id/eprint/55958/1/Dual-fuzzy%20MPPT%20in%20photovoltaic-DC%20analysis%20for%20dual-load%20operation%20with%20SEPIC%20converter.pdf