Evaluation of a technique to measure heart rate variability in anaesthetised cats

Analysis of heart rate (HR) and heart rate variability (HRV) are powerful tools to investigate cardiac diseases, but current methods, including 24-h Holter monitoring, can be cumbersome and may be compromised by movement artefact. A commercially available data capture and analysis system was used in...

Full description

Bibliographic Details
Main Authors: Khor, Kuan Hua, Shiels, Ian A., Campbell, Fiona E., Greer, Ristan M., Rose, Annie, Mills, Paul C.
Format: Article
Language:English
Published: Elsevier 2014
Online Access:http://psasir.upm.edu.my/id/eprint/37518/
http://psasir.upm.edu.my/id/eprint/37518/1/Evaluation%20of%20a%20technique%20to%20measure%20heart%20rate%20variability%20in%20anaesthetised%20cats.pdf
_version_ 1848848629519876096
author Khor, Kuan Hua
Shiels, Ian A.
Campbell, Fiona E.
Greer, Ristan M.
Rose, Annie
Mills, Paul C.
author_facet Khor, Kuan Hua
Shiels, Ian A.
Campbell, Fiona E.
Greer, Ristan M.
Rose, Annie
Mills, Paul C.
author_sort Khor, Kuan Hua
building UPM Institutional Repository
collection Online Access
description Analysis of heart rate (HR) and heart rate variability (HRV) are powerful tools to investigate cardiac diseases, but current methods, including 24-h Holter monitoring, can be cumbersome and may be compromised by movement artefact. A commercially available data capture and analysis system was used in anaesthetised healthy cats to measure HR and HRV during pharmacological manipulation of HR. Seven healthy cats were subjected to a randomised crossover study design with a 7 day washout period between two treatment groups, placebo and atenolol (1 mg/kg, IV), with the efficacy of atenolol to inhibit β1 adrenoreceptors challenged by epinephrine. Statistical significance for the epinephrine challenge was set at P < 0.0027 (Holm–Bonferroni correction), whereas a level of significance of P < 0.05 was set for other variables. Analysis of the continuous electrocardiography (ECG) recordings showed that epinephrine challenge increased HR in the placebo group (P = 0.0003) but not in the atenolol group. The change in HR was greater in the placebo group than in the atenolol group (P = 0.0004). Therefore, compared to cats pre-treated with placebo, pre-treatment with atenolol significantly antagonised the tachycardia while not significantly affecting HRV. The increased HR in the placebo group following epinephrine challenge was consistent with a shift of the sympathovagal balance towards a predominantly sympathetic tone. However, the small (but not significant at the critical value) decrease in the normalised high-frequency component (HFnorm) in both groups of cats suggested that epinephrine induced a parasympathetic withdrawal in addition to sympathetic enhancement (increased normalised low frequency component or LFnorm). In conclusion, this model is a highly sensitive and repeatable model to investigate HRV in anaesthetised cats that would be useful in the laboratory setting for short-term investigation of cardiovascular disease and subtle responses to pharmacological agents in this species.
first_indexed 2025-11-15T09:37:32Z
format Article
id upm-37518
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T09:37:32Z
publishDate 2014
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling upm-375182015-12-18T02:49:44Z http://psasir.upm.edu.my/id/eprint/37518/ Evaluation of a technique to measure heart rate variability in anaesthetised cats Khor, Kuan Hua Shiels, Ian A. Campbell, Fiona E. Greer, Ristan M. Rose, Annie Mills, Paul C. Analysis of heart rate (HR) and heart rate variability (HRV) are powerful tools to investigate cardiac diseases, but current methods, including 24-h Holter monitoring, can be cumbersome and may be compromised by movement artefact. A commercially available data capture and analysis system was used in anaesthetised healthy cats to measure HR and HRV during pharmacological manipulation of HR. Seven healthy cats were subjected to a randomised crossover study design with a 7 day washout period between two treatment groups, placebo and atenolol (1 mg/kg, IV), with the efficacy of atenolol to inhibit β1 adrenoreceptors challenged by epinephrine. Statistical significance for the epinephrine challenge was set at P < 0.0027 (Holm–Bonferroni correction), whereas a level of significance of P < 0.05 was set for other variables. Analysis of the continuous electrocardiography (ECG) recordings showed that epinephrine challenge increased HR in the placebo group (P = 0.0003) but not in the atenolol group. The change in HR was greater in the placebo group than in the atenolol group (P = 0.0004). Therefore, compared to cats pre-treated with placebo, pre-treatment with atenolol significantly antagonised the tachycardia while not significantly affecting HRV. The increased HR in the placebo group following epinephrine challenge was consistent with a shift of the sympathovagal balance towards a predominantly sympathetic tone. However, the small (but not significant at the critical value) decrease in the normalised high-frequency component (HFnorm) in both groups of cats suggested that epinephrine induced a parasympathetic withdrawal in addition to sympathetic enhancement (increased normalised low frequency component or LFnorm). In conclusion, this model is a highly sensitive and repeatable model to investigate HRV in anaesthetised cats that would be useful in the laboratory setting for short-term investigation of cardiovascular disease and subtle responses to pharmacological agents in this species. Elsevier 2014-02 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/37518/1/Evaluation%20of%20a%20technique%20to%20measure%20heart%20rate%20variability%20in%20anaesthetised%20cats.pdf Khor, Kuan Hua and Shiels, Ian A. and Campbell, Fiona E. and Greer, Ristan M. and Rose, Annie and Mills, Paul C. (2014) Evaluation of a technique to measure heart rate variability in anaesthetised cats. The Veterinary Journal, 199 (2). pp. 229-235. ISSN 1090-0233; ESSN: 1532-2971 http://www.sciencedirect.com/science/article/pii/S1090023313005625 10.1016/j.tvjl.2013.11.006
spellingShingle Khor, Kuan Hua
Shiels, Ian A.
Campbell, Fiona E.
Greer, Ristan M.
Rose, Annie
Mills, Paul C.
Evaluation of a technique to measure heart rate variability in anaesthetised cats
title Evaluation of a technique to measure heart rate variability in anaesthetised cats
title_full Evaluation of a technique to measure heart rate variability in anaesthetised cats
title_fullStr Evaluation of a technique to measure heart rate variability in anaesthetised cats
title_full_unstemmed Evaluation of a technique to measure heart rate variability in anaesthetised cats
title_short Evaluation of a technique to measure heart rate variability in anaesthetised cats
title_sort evaluation of a technique to measure heart rate variability in anaesthetised cats
url http://psasir.upm.edu.my/id/eprint/37518/
http://psasir.upm.edu.my/id/eprint/37518/
http://psasir.upm.edu.my/id/eprint/37518/
http://psasir.upm.edu.my/id/eprint/37518/1/Evaluation%20of%20a%20technique%20to%20measure%20heart%20rate%20variability%20in%20anaesthetised%20cats.pdf