Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS.
This paper concerns with transient stability control which is part of transient stability assessment which needs to be considered so that the power systems remained intact when failures originating from faults occurred in power systems. Conventional under frequency load shedding (UFLS) system is des...
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English English |
| Published: |
Federico II University
2010
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/17476/ http://psasir.upm.edu.my/id/eprint/17476/1/Transient%20stability%20emergency%20control%20using%20generator%20tripping%20based%20on%20tracking%20area.pdf |
| _version_ | 1848843251976503296 |
|---|---|
| author | Abdul Wahab, Noor Izzri Mohamed, Azah |
| author_facet | Abdul Wahab, Noor Izzri Mohamed, Azah |
| author_sort | Abdul Wahab, Noor Izzri |
| building | UPM Institutional Repository |
| collection | Online Access |
| description | This paper concerns with transient stability control which is part of transient stability assessment which needs to be considered so that the power systems remained intact when failures originating from faults occurred in power systems. Conventional under frequency load shedding (UFLS) system is designed to retrieve the balance of generation and consumption following disturbances occurrences in the system. In UFLS method, whenever the system's frequency drops below a predetermined value, the system loads are shed in stages. An efficient UFLS method needs to be devised so as to reduce the impacts of transient disturbance on power systems and prevent total system blackout. In this paper, an emergency control scheme known as the combined UFLS and generator tripping is developed in order to stabilize the system when unstable faults occurred in a power system. The performance of the combined UFLS and generator tripping scheme is compared with the conventional UFLS control scheme. The results show that the combined control scheme performed better.
|
| first_indexed | 2025-11-15T08:12:04Z |
| format | Article |
| id | upm-17476 |
| institution | Universiti Putra Malaysia |
| institution_category | Local University |
| language | English English |
| last_indexed | 2025-11-15T08:12:04Z |
| publishDate | 2010 |
| publisher | Federico II University |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | upm-174762015-11-05T08:49:18Z http://psasir.upm.edu.my/id/eprint/17476/ Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS. Abdul Wahab, Noor Izzri Mohamed, Azah This paper concerns with transient stability control which is part of transient stability assessment which needs to be considered so that the power systems remained intact when failures originating from faults occurred in power systems. Conventional under frequency load shedding (UFLS) system is designed to retrieve the balance of generation and consumption following disturbances occurrences in the system. In UFLS method, whenever the system's frequency drops below a predetermined value, the system loads are shed in stages. An efficient UFLS method needs to be devised so as to reduce the impacts of transient disturbance on power systems and prevent total system blackout. In this paper, an emergency control scheme known as the combined UFLS and generator tripping is developed in order to stabilize the system when unstable faults occurred in a power system. The performance of the combined UFLS and generator tripping scheme is compared with the conventional UFLS control scheme. The results show that the combined control scheme performed better. Federico II University 2010 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/17476/1/Transient%20stability%20emergency%20control%20using%20generator%20tripping%20based%20on%20tracking%20area.pdf Abdul Wahab, Noor Izzri and Mohamed, Azah (2010) Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS. International Review of Electrical Engineering, 5 (5). pp. 2317-2326. ISSN 1827-6660 English |
| spellingShingle | Abdul Wahab, Noor Izzri Mohamed, Azah Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS. |
| title | Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS. |
| title_full | Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS. |
| title_fullStr | Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS. |
| title_full_unstemmed | Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS. |
| title_short | Transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with UFLS. |
| title_sort | transient stability emergency control using generator tripping based on tracking area-based rotor angle combined with ufls. |
| url | http://psasir.upm.edu.my/id/eprint/17476/ http://psasir.upm.edu.my/id/eprint/17476/1/Transient%20stability%20emergency%20control%20using%20generator%20tripping%20based%20on%20tracking%20area.pdf |