Development of functional electrical stimulator with movement feedback parameter for muscle activation level detection / Nazurah Ahmad Termimi

Functional electrical stimulation (FES) was widely used in rehabilitation for restoring body function by stimulating the muscle with certain amount of current. An alternative of feedback parameter for muscle activation detection was studied. A movement feedback parameter was chosen to detect musc...

Full description

Bibliographic Details
Main Author: Nazurah, Ahmad Termimi
Format: Thesis
Published: 2012
Subjects:
Online Access:http://studentsrepo.um.edu.my/7621/
http://studentsrepo.um.edu.my/7621/1/nazurah.pdf
_version_ 1848773441064271872
author Nazurah, Ahmad Termimi
author_facet Nazurah, Ahmad Termimi
author_sort Nazurah, Ahmad Termimi
building UM Research Repository
collection Online Access
description Functional electrical stimulation (FES) was widely used in rehabilitation for restoring body function by stimulating the muscle with certain amount of current. An alternative of feedback parameter for muscle activation detection was studied. A movement feedback parameter was chosen to detect muscle activation. Two flexible bend sensors were used to detect muscle movement. In this study, consists of three parts. First part, a stimulator would be developed. Second part, flexible bend sensor embedded to the stimulator for muscle movement detection. Third part, stimulator supplied current through stimulation electrodes for muscle activation and muscle movement detected by flexible bend sensor. Flexible bend sensors were undergo a voluntary and non-voluntary test to observed the voltage output change with the muscle activation relationship. For voluntary test, there are two separate sessions. The first session, a subject was asked to cycle for 20 minutes. For every five minutes, the first three reading displayed on screen will be recorded. The second session, subject also need to do cycling but data recording was different. By using sampling time of five seconds, an output voltage reading from muscle activation was recorded. For non-voluntary test, current was supplied to vastus medialis muscle and the muscle contraction and relaxation were recorded. In conclusion, muscle activation can be detected by muscle movement sensed by flexible bend sensor. Based on the basic circuit of flexible bend sensor which is voltage divider, when muscle contracted, bending angle and resistance increased, voltage output was low. When muscle relaxes, bending angle ad resistance decreased and voltage output was high.
first_indexed 2025-11-14T13:42:27Z
format Thesis
id um-7621
institution University Malaya
institution_category Local University
last_indexed 2025-11-14T13:42:27Z
publishDate 2012
recordtype eprints
repository_type Digital Repository
spelling um-76212020-01-18T02:04:12Z Development of functional electrical stimulator with movement feedback parameter for muscle activation level detection / Nazurah Ahmad Termimi Nazurah, Ahmad Termimi RD Surgery T Technology (General) Functional electrical stimulation (FES) was widely used in rehabilitation for restoring body function by stimulating the muscle with certain amount of current. An alternative of feedback parameter for muscle activation detection was studied. A movement feedback parameter was chosen to detect muscle activation. Two flexible bend sensors were used to detect muscle movement. In this study, consists of three parts. First part, a stimulator would be developed. Second part, flexible bend sensor embedded to the stimulator for muscle movement detection. Third part, stimulator supplied current through stimulation electrodes for muscle activation and muscle movement detected by flexible bend sensor. Flexible bend sensors were undergo a voluntary and non-voluntary test to observed the voltage output change with the muscle activation relationship. For voluntary test, there are two separate sessions. The first session, a subject was asked to cycle for 20 minutes. For every five minutes, the first three reading displayed on screen will be recorded. The second session, subject also need to do cycling but data recording was different. By using sampling time of five seconds, an output voltage reading from muscle activation was recorded. For non-voluntary test, current was supplied to vastus medialis muscle and the muscle contraction and relaxation were recorded. In conclusion, muscle activation can be detected by muscle movement sensed by flexible bend sensor. Based on the basic circuit of flexible bend sensor which is voltage divider, when muscle contracted, bending angle and resistance increased, voltage output was low. When muscle relaxes, bending angle ad resistance decreased and voltage output was high. 2012 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/7621/1/nazurah.pdf Nazurah, Ahmad Termimi (2012) Development of functional electrical stimulator with movement feedback parameter for muscle activation level detection / Nazurah Ahmad Termimi. Masters thesis, University of Malaya. http://studentsrepo.um.edu.my/7621/
spellingShingle RD Surgery
T Technology (General)
Nazurah, Ahmad Termimi
Development of functional electrical stimulator with movement feedback parameter for muscle activation level detection / Nazurah Ahmad Termimi
title Development of functional electrical stimulator with movement feedback parameter for muscle activation level detection / Nazurah Ahmad Termimi
title_full Development of functional electrical stimulator with movement feedback parameter for muscle activation level detection / Nazurah Ahmad Termimi
title_fullStr Development of functional electrical stimulator with movement feedback parameter for muscle activation level detection / Nazurah Ahmad Termimi
title_full_unstemmed Development of functional electrical stimulator with movement feedback parameter for muscle activation level detection / Nazurah Ahmad Termimi
title_short Development of functional electrical stimulator with movement feedback parameter for muscle activation level detection / Nazurah Ahmad Termimi
title_sort development of functional electrical stimulator with movement feedback parameter for muscle activation level detection / nazurah ahmad termimi
topic RD Surgery
T Technology (General)
url http://studentsrepo.um.edu.my/7621/
http://studentsrepo.um.edu.my/7621/1/nazurah.pdf