Measurement of neutron flux and gamma dose rate distribution inside a water phantom for Boron Neutron Capture Therapy study at Dalat Research Reactor

Exposure dose rate to the tumor and surrounding cells during neutron beam irradiation in Boron Neutron Capture Therapy (BNCT) comes not only from heavy charged particles produced from the 10B(n,α)7Li nuclear reaction, but also from neutron-induced reactions with other biological elements in living t...

Full description

Bibliographic Details
Main Authors: Trinh, Thi Tu Anh, Pham, Dang Quyet, Mai, Nguyen Trong Nhan, Pham, Ngoc Son
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2019
Online Access:http://journalarticle.ukm.my/13068/
http://journalarticle.ukm.my/13068/1/22%20Trinh%20Thi%20Tu%20Anh.pdf
_version_ 1848813172570456064
author Trinh, Thi Tu Anh
Pham, Dang Quyet
Mai, Nguyen Trong Nhan
Pham, Ngoc Son
author_facet Trinh, Thi Tu Anh
Pham, Dang Quyet
Mai, Nguyen Trong Nhan
Pham, Ngoc Son
author_sort Trinh, Thi Tu Anh
building UKM Institutional Repository
collection Online Access
description Exposure dose rate to the tumor and surrounding cells during neutron beam irradiation in Boron Neutron Capture Therapy (BNCT) comes not only from heavy charged particles produced from the 10B(n,α)7Li nuclear reaction, but also from neutron-induced reactions with other biological elements in living tissue, as well as from gamma rays leaked from the reactor core. At Dalat Research Reactor, Vietnam, the neutron and gamma dose rate distribution inside a water phantom were measured by using activation method and Thermoluminescent Dosimeter (TLD) detector, respectively. The results showed that effective thermal neutron dose rate along the center line of the water phantom had a maximum value of 479 mSv h-1 at 1 cm in phantom and then decreases rapidly to 4.87 mSv h-1 at 10 cm. The gamma dose rate along the center line of the water phantom also reach its maximum of 4.31 mSv h-1 at 1 cm depth and decreases to 1.16 mSv h-1 at 10 cm position. The maximum biological tumor dose rate was 1.74 Gy-eq h-1, not high enough to satisfy the treatment requirement of brain tumors. However, the results of this work are important in supporting of BNCT study in the upcoming stages at Dalat Research Reactor.
first_indexed 2025-11-15T00:13:58Z
format Article
id oai:generic.eprints.org:13068
institution Universiti Kebangasaan Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T00:13:58Z
publishDate 2019
publisher Penerbit Universiti Kebangsaan Malaysia
recordtype eprints
repository_type Digital Repository
spelling oai:generic.eprints.org:130682019-06-20T14:49:32Z http://journalarticle.ukm.my/13068/ Measurement of neutron flux and gamma dose rate distribution inside a water phantom for Boron Neutron Capture Therapy study at Dalat Research Reactor Trinh, Thi Tu Anh Pham, Dang Quyet Mai, Nguyen Trong Nhan Pham, Ngoc Son Exposure dose rate to the tumor and surrounding cells during neutron beam irradiation in Boron Neutron Capture Therapy (BNCT) comes not only from heavy charged particles produced from the 10B(n,α)7Li nuclear reaction, but also from neutron-induced reactions with other biological elements in living tissue, as well as from gamma rays leaked from the reactor core. At Dalat Research Reactor, Vietnam, the neutron and gamma dose rate distribution inside a water phantom were measured by using activation method and Thermoluminescent Dosimeter (TLD) detector, respectively. The results showed that effective thermal neutron dose rate along the center line of the water phantom had a maximum value of 479 mSv h-1 at 1 cm in phantom and then decreases rapidly to 4.87 mSv h-1 at 10 cm. The gamma dose rate along the center line of the water phantom also reach its maximum of 4.31 mSv h-1 at 1 cm depth and decreases to 1.16 mSv h-1 at 10 cm position. The maximum biological tumor dose rate was 1.74 Gy-eq h-1, not high enough to satisfy the treatment requirement of brain tumors. However, the results of this work are important in supporting of BNCT study in the upcoming stages at Dalat Research Reactor. Penerbit Universiti Kebangsaan Malaysia 2019-01 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/13068/1/22%20Trinh%20Thi%20Tu%20Anh.pdf Trinh, Thi Tu Anh and Pham, Dang Quyet and Mai, Nguyen Trong Nhan and Pham, Ngoc Son (2019) Measurement of neutron flux and gamma dose rate distribution inside a water phantom for Boron Neutron Capture Therapy study at Dalat Research Reactor. Sains Malaysiana, 48 (1). pp. 191-197. ISSN 0126-6039 http://www.ukm.my/jsm/malay_journals/jilid48bil1_2019/KandunganJilid48Bil1_2019.html
spellingShingle Trinh, Thi Tu Anh
Pham, Dang Quyet
Mai, Nguyen Trong Nhan
Pham, Ngoc Son
Measurement of neutron flux and gamma dose rate distribution inside a water phantom for Boron Neutron Capture Therapy study at Dalat Research Reactor
title Measurement of neutron flux and gamma dose rate distribution inside a water phantom for Boron Neutron Capture Therapy study at Dalat Research Reactor
title_full Measurement of neutron flux and gamma dose rate distribution inside a water phantom for Boron Neutron Capture Therapy study at Dalat Research Reactor
title_fullStr Measurement of neutron flux and gamma dose rate distribution inside a water phantom for Boron Neutron Capture Therapy study at Dalat Research Reactor
title_full_unstemmed Measurement of neutron flux and gamma dose rate distribution inside a water phantom for Boron Neutron Capture Therapy study at Dalat Research Reactor
title_short Measurement of neutron flux and gamma dose rate distribution inside a water phantom for Boron Neutron Capture Therapy study at Dalat Research Reactor
title_sort measurement of neutron flux and gamma dose rate distribution inside a water phantom for boron neutron capture therapy study at dalat research reactor
url http://journalarticle.ukm.my/13068/
http://journalarticle.ukm.my/13068/
http://journalarticle.ukm.my/13068/1/22%20Trinh%20Thi%20Tu%20Anh.pdf