Advancement of the Quantitative Blood Oxygenation Level-Dependent (qBOLD) MRI technique to improve clinical feasibility.

Quantitative Blood Oxygenation Level Dependent (qBOLD) MRI offers a non- invasive method for measuring brain oxygenation, with potential applications in various neurological conditions. However, its clinical implementation has been hindered by methodological inconsistencies and challenges in standar...

Full description

Bibliographic Details
Main Author: Alzaidi, Ahlam
Format: Thesis (University of Nottingham only)
Language:English
Published: 2025
Subjects:
Online Access:https://eprints.nottingham.ac.uk/80805/
_version_ 1848801273285967872
author Alzaidi, Ahlam
author_facet Alzaidi, Ahlam
author_sort Alzaidi, Ahlam
building Nottingham Research Data Repository
collection Online Access
description Quantitative Blood Oxygenation Level Dependent (qBOLD) MRI offers a non- invasive method for measuring brain oxygenation, with potential applications in various neurological conditions. However, its clinical implementation has been hindered by methodological inconsistencies and challenges in standardisation. This thesis aims to address these obstacles and advance the clinical applicability of qBOLD techniques through three studies. First, a comprehensive scoping review of the qBOLD literature was conducted. The review revealed four main qBOLD acquisition methods: multiparametric (mp- qBOLD), asymmetric spin echo (ASE), gradient echo (GRE), and gradient echo sampling of spin echo (GESSE). Notably, mp-qBOLD emerged as the most used technique, likely due to its easier implementation in clinical settings. However, significant variability in the reversible transverse relaxation rate (R2') measurements across different acquisition techniques was observed, highlighting the need for standardisation. To address this variability and enable quality assurance, the second study focused on developing and validating a new qBOLD phantom using glass microspheres. A linear relationship between R2' contrast and glass bubble volume fraction was established, and the phantom demonstrated good reproducibility in construction and MRI measurements. Crucially, R2' measurements were consistent across different qBOLD acquisitions and MRI vendors and the phantom accurately replicated known in vivo R2' values for human brain tissue. However, challenges arose in matching the irreversible transverse relaxation rate (R2) values to the human brain range. The third study explored a combined hyperoxia-BOLD and mp-qBOLD (hmp- qBOLD) approach to improve oxygen extraction fraction (OEF) estimation in a clinically translatable manner. This combined method overestimated OEF compared to an established technique, with values exceeding normal physiological ranges. In conclusion, this thesis has made important contributions towards addressing key challenges to the clinical implementation of qBOLD imaging, laying a solid foundation for future advancements in quantitative oxygenation imaging and its translation to clinical practice.
first_indexed 2025-11-14T21:04:50Z
format Thesis (University of Nottingham only)
id nottingham-80805
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T21:04:50Z
publishDate 2025
recordtype eprints
repository_type Digital Repository
spelling nottingham-808052025-07-24T04:40:14Z https://eprints.nottingham.ac.uk/80805/ Advancement of the Quantitative Blood Oxygenation Level-Dependent (qBOLD) MRI technique to improve clinical feasibility. Alzaidi, Ahlam Quantitative Blood Oxygenation Level Dependent (qBOLD) MRI offers a non- invasive method for measuring brain oxygenation, with potential applications in various neurological conditions. However, its clinical implementation has been hindered by methodological inconsistencies and challenges in standardisation. This thesis aims to address these obstacles and advance the clinical applicability of qBOLD techniques through three studies. First, a comprehensive scoping review of the qBOLD literature was conducted. The review revealed four main qBOLD acquisition methods: multiparametric (mp- qBOLD), asymmetric spin echo (ASE), gradient echo (GRE), and gradient echo sampling of spin echo (GESSE). Notably, mp-qBOLD emerged as the most used technique, likely due to its easier implementation in clinical settings. However, significant variability in the reversible transverse relaxation rate (R2') measurements across different acquisition techniques was observed, highlighting the need for standardisation. To address this variability and enable quality assurance, the second study focused on developing and validating a new qBOLD phantom using glass microspheres. A linear relationship between R2' contrast and glass bubble volume fraction was established, and the phantom demonstrated good reproducibility in construction and MRI measurements. Crucially, R2' measurements were consistent across different qBOLD acquisitions and MRI vendors and the phantom accurately replicated known in vivo R2' values for human brain tissue. However, challenges arose in matching the irreversible transverse relaxation rate (R2) values to the human brain range. The third study explored a combined hyperoxia-BOLD and mp-qBOLD (hmp- qBOLD) approach to improve oxygen extraction fraction (OEF) estimation in a clinically translatable manner. This combined method overestimated OEF compared to an established technique, with values exceeding normal physiological ranges. In conclusion, this thesis has made important contributions towards addressing key challenges to the clinical implementation of qBOLD imaging, laying a solid foundation for future advancements in quantitative oxygenation imaging and its translation to clinical practice. 2025-07-24 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en cc_by https://eprints.nottingham.ac.uk/80805/2/AA_Thesis-v6_annotated_.pdf Alzaidi, Ahlam (2025) Advancement of the Quantitative Blood Oxygenation Level-Dependent (qBOLD) MRI technique to improve clinical feasibility. PhD thesis, University of Nottingham. oxygenation qBOLD techniques standardisation glass microspheres oxygen extraction fraction estimation oxygenation imaging
spellingShingle oxygenation
qBOLD techniques
standardisation
glass microspheres
oxygen extraction fraction estimation
oxygenation imaging
Alzaidi, Ahlam
Advancement of the Quantitative Blood Oxygenation Level-Dependent (qBOLD) MRI technique to improve clinical feasibility.
title Advancement of the Quantitative Blood Oxygenation Level-Dependent (qBOLD) MRI technique to improve clinical feasibility.
title_full Advancement of the Quantitative Blood Oxygenation Level-Dependent (qBOLD) MRI technique to improve clinical feasibility.
title_fullStr Advancement of the Quantitative Blood Oxygenation Level-Dependent (qBOLD) MRI technique to improve clinical feasibility.
title_full_unstemmed Advancement of the Quantitative Blood Oxygenation Level-Dependent (qBOLD) MRI technique to improve clinical feasibility.
title_short Advancement of the Quantitative Blood Oxygenation Level-Dependent (qBOLD) MRI technique to improve clinical feasibility.
title_sort advancement of the quantitative blood oxygenation level-dependent (qbold) mri technique to improve clinical feasibility.
topic oxygenation
qBOLD techniques
standardisation
glass microspheres
oxygen extraction fraction estimation
oxygenation imaging
url https://eprints.nottingham.ac.uk/80805/