Radio-Frequency Optically Pumped Magnetometers for Eddy Current Measurements

Radio-frequency optically pumped magnetometers (RF OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Two types of RF OPMs are presented in this thesis. The first is a portable, orientation-based RF OPM with 600 fT/sqrt(Hz) sensitivity at 10 kH...

Full description

Bibliographic Details
Main Author: Rushton, Lucas Martin
Format: Thesis (University of Nottingham only)
Language:English
Published: 2023
Subjects:
Online Access:https://eprints.nottingham.ac.uk/73052/
_version_ 1848800760755650560
author Rushton, Lucas Martin
author_facet Rushton, Lucas Martin
author_sort Rushton, Lucas Martin
building Nottingham Research Data Repository
collection Online Access
description Radio-frequency optically pumped magnetometers (RF OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Two types of RF OPMs are presented in this thesis. The first is a portable, orientation-based RF OPM with 600 fT/sqrt(Hz) sensitivity at 10 kHz in unshielded conditions, a new benchmark for a portable unshielded RF OPM, and 200 fT/sqrt(Hz) sensitivity at 10 kHz in shielded conditions, close to the spin projection noise limit. Eddy current measurements were performed with this OPM to remotely detect aluminium disks with diameters as small as 1.5 cm at distances of ~25 cm from both the excitation coil and the OPM, demonstrating the possibility of using OPMs for remote sensing. Off-axis measurements were performed with this OPM to illustrate how the OPM readout can be interpreted for remote sensing. All aspects of the theory, experimental setup and results relevant for this orientation-based RF OPM and eddy current measurements are presented in this thesis. The second OPM presented is a table-top alignment-based RF OPM in shielded conditions using a buffer gas cell. The benefit of alignment-based magnetometers over orientation-based RF OPMs is that they require only one laser beam, making them compact and robust. Until now, the alignment-based magnetometer had only been used with hand-blown paraffin-coated cells, but not with buffer gas cells that can be produced on a mass scale using microfabrication techniques. We present here an alignment-based magnetometer using a buffer gas cell (Cs and N2). This one-beam RF OPM with a buffer gas cell obtained a sensitivity of 325 fT/sqrt(Hz) with an 800 Hz bandwidth to 10 kHz oscillating magnetic fields and is calculated to be close to the spin projection noise limit. The non-linear Zeeman splitting is observed with both the buffer gas cell and a paraffin-coated cell. These results open up the possibility for commercialisation and further miniaturisation of RF OPMs. We derive a set of equations for the off-axis detection of electrically conductive spheres for the arbitrary positioning of the sphere and magnetometer. The equations are interpreted with a focus on predicting the expected signals for the imaging of the electrical conductivity of the human heart using RF OPMs to potentially help diagnose atrial fibrillation more effectively in the future. The optimal setups are discussed. Details on how to design compact, low-noise balanced photodetectors are discussed. Several printed circuit board designs are presented and tested. The performance of the balanced photodetector exceeds that of a commercial balanced photodetector at low frequencies, being shot noise limited for powers as low as 3 uW at frequencies of 3 kHz.
first_indexed 2025-11-14T20:56:41Z
format Thesis (University of Nottingham only)
id nottingham-73052
institution University of Nottingham Malaysia Campus
institution_category Local University
language English
last_indexed 2025-11-14T20:56:41Z
publishDate 2023
recordtype eprints
repository_type Digital Repository
spelling nottingham-730522023-07-26T04:40:21Z https://eprints.nottingham.ac.uk/73052/ Radio-Frequency Optically Pumped Magnetometers for Eddy Current Measurements Rushton, Lucas Martin Radio-frequency optically pumped magnetometers (RF OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Two types of RF OPMs are presented in this thesis. The first is a portable, orientation-based RF OPM with 600 fT/sqrt(Hz) sensitivity at 10 kHz in unshielded conditions, a new benchmark for a portable unshielded RF OPM, and 200 fT/sqrt(Hz) sensitivity at 10 kHz in shielded conditions, close to the spin projection noise limit. Eddy current measurements were performed with this OPM to remotely detect aluminium disks with diameters as small as 1.5 cm at distances of ~25 cm from both the excitation coil and the OPM, demonstrating the possibility of using OPMs for remote sensing. Off-axis measurements were performed with this OPM to illustrate how the OPM readout can be interpreted for remote sensing. All aspects of the theory, experimental setup and results relevant for this orientation-based RF OPM and eddy current measurements are presented in this thesis. The second OPM presented is a table-top alignment-based RF OPM in shielded conditions using a buffer gas cell. The benefit of alignment-based magnetometers over orientation-based RF OPMs is that they require only one laser beam, making them compact and robust. Until now, the alignment-based magnetometer had only been used with hand-blown paraffin-coated cells, but not with buffer gas cells that can be produced on a mass scale using microfabrication techniques. We present here an alignment-based magnetometer using a buffer gas cell (Cs and N2). This one-beam RF OPM with a buffer gas cell obtained a sensitivity of 325 fT/sqrt(Hz) with an 800 Hz bandwidth to 10 kHz oscillating magnetic fields and is calculated to be close to the spin projection noise limit. The non-linear Zeeman splitting is observed with both the buffer gas cell and a paraffin-coated cell. These results open up the possibility for commercialisation and further miniaturisation of RF OPMs. We derive a set of equations for the off-axis detection of electrically conductive spheres for the arbitrary positioning of the sphere and magnetometer. The equations are interpreted with a focus on predicting the expected signals for the imaging of the electrical conductivity of the human heart using RF OPMs to potentially help diagnose atrial fibrillation more effectively in the future. The optimal setups are discussed. Details on how to design compact, low-noise balanced photodetectors are discussed. Several printed circuit board designs are presented and tested. The performance of the balanced photodetector exceeds that of a commercial balanced photodetector at low frequencies, being shot noise limited for powers as low as 3 uW at frequencies of 3 kHz. 2023-07-26 Thesis (University of Nottingham only) NonPeerReviewed application/pdf en cc_by https://eprints.nottingham.ac.uk/73052/1/PhD_Thesis.pdf Rushton, Lucas Martin (2023) Radio-Frequency Optically Pumped Magnetometers for Eddy Current Measurements. PhD thesis, University of Nottingham. Eddy current measurement optically pumped magnetometer atomic magnetometer quantum physics magnetometry electromagnetic induction atomic physics.
spellingShingle Eddy current measurement
optically pumped magnetometer
atomic magnetometer
quantum physics
magnetometry
electromagnetic induction
atomic physics.
Rushton, Lucas Martin
Radio-Frequency Optically Pumped Magnetometers for Eddy Current Measurements
title Radio-Frequency Optically Pumped Magnetometers for Eddy Current Measurements
title_full Radio-Frequency Optically Pumped Magnetometers for Eddy Current Measurements
title_fullStr Radio-Frequency Optically Pumped Magnetometers for Eddy Current Measurements
title_full_unstemmed Radio-Frequency Optically Pumped Magnetometers for Eddy Current Measurements
title_short Radio-Frequency Optically Pumped Magnetometers for Eddy Current Measurements
title_sort radio-frequency optically pumped magnetometers for eddy current measurements
topic Eddy current measurement
optically pumped magnetometer
atomic magnetometer
quantum physics
magnetometry
electromagnetic induction
atomic physics.
url https://eprints.nottingham.ac.uk/73052/