Self-commissioning of interior permanent- magnet synchronous motor drives with high-frequency current injection
In this paper, a simple and robust method for parameter estimation at rotor standstill is presented for interior permanent magnet (IPM) synchronous machines. The estimated parameters are the stator resistance through dc test, the dq inductances using high-frequency injection, and the permanent magne...