Impact of the carbon pore size and topology on the equilibrium quantum sieving of hydrogen isotopes at zero coverage and finite pressures

Carbonaceous slit-shaped and square-shaped pores efficiently differentiate adsorbed hydrogenisotopes at 77 and 33 K. Extensive path integral Monte Carlo simulations revealed that thesquare-shaped carbon pores enhanced the selectivity of deuterium over hydrogen in comparisonto equivalent slit-shaped...

Full description

Bibliographic Details
Main Authors: Kowalczyk, Poitr, Gauden, P., Terzyk, A., Furmaniak, S.
Format: Journal Article
Published: IOP Publishing Ltd 2009
Online Access:http://stacks.iop.org/JPhysCM/21/144210
http://hdl.handle.net/20.500.11937/8941
_version_ 1848745806442528768
author Kowalczyk, Poitr
Gauden, P.
Terzyk, A.
Furmaniak, S.
author_facet Kowalczyk, Poitr
Gauden, P.
Terzyk, A.
Furmaniak, S.
author_sort Kowalczyk, Poitr
building Curtin Institutional Repository
collection Online Access
description Carbonaceous slit-shaped and square-shaped pores efficiently differentiate adsorbed hydrogenisotopes at 77 and 33 K. Extensive path integral Monte Carlo simulations revealed that thesquare-shaped carbon pores enhanced the selectivity of deuterium over hydrogen in comparisonto equivalent slit-shaped carbon pores at zero coverage as well as at finite pressures(i.e. quantum sieving of hydrogen isotopes is pore-topology-dependent). We show that thisenhancement of the D2/H2 equilibrium selectivity results from larger localization of hydrogenisotopes in square-shaped pores. The operating pressures for efficient quantum sieving ofhydrogen isotopes are strongly dependent on the topology as well as on the size of the carbonpores. However, for both considered carbon pore topologies the highest D2/H2 separation factoris observed at zero-coverage limit. Depending on carbon pore size and topology we predictedmonotonic decreasing and non-monotonic shape of the D2/H2 equilibrium selectivity at finitepressures. For both kinds of carbonaceous pores of molecular sizes we predict highcompression of hydrogen isotopes at 77 and 33 K (for example, the pore density of compressedhydrogen isotopes at 77 K and 0.25 MPa in a square-shaped carbon pore of size 2.6 °A exceeds60 mmol cm-3; for comparison, the liquid density of para-H2 at 30 K and 30 MPa is42 mmol cm-3). Finally, by direct comparison of simulation results with experimental data it isexplained why ‘ordinary’ carbonaceous materials are not efficient quantum sieves.
first_indexed 2025-11-14T06:23:13Z
format Journal Article
id curtin-20.500.11937-8941
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T06:23:13Z
publishDate 2009
publisher IOP Publishing Ltd
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-89412017-02-28T01:31:01Z Impact of the carbon pore size and topology on the equilibrium quantum sieving of hydrogen isotopes at zero coverage and finite pressures Kowalczyk, Poitr Gauden, P. Terzyk, A. Furmaniak, S. Carbonaceous slit-shaped and square-shaped pores efficiently differentiate adsorbed hydrogenisotopes at 77 and 33 K. Extensive path integral Monte Carlo simulations revealed that thesquare-shaped carbon pores enhanced the selectivity of deuterium over hydrogen in comparisonto equivalent slit-shaped carbon pores at zero coverage as well as at finite pressures(i.e. quantum sieving of hydrogen isotopes is pore-topology-dependent). We show that thisenhancement of the D2/H2 equilibrium selectivity results from larger localization of hydrogenisotopes in square-shaped pores. The operating pressures for efficient quantum sieving ofhydrogen isotopes are strongly dependent on the topology as well as on the size of the carbonpores. However, for both considered carbon pore topologies the highest D2/H2 separation factoris observed at zero-coverage limit. Depending on carbon pore size and topology we predictedmonotonic decreasing and non-monotonic shape of the D2/H2 equilibrium selectivity at finitepressures. For both kinds of carbonaceous pores of molecular sizes we predict highcompression of hydrogen isotopes at 77 and 33 K (for example, the pore density of compressedhydrogen isotopes at 77 K and 0.25 MPa in a square-shaped carbon pore of size 2.6 °A exceeds60 mmol cm-3; for comparison, the liquid density of para-H2 at 30 K and 30 MPa is42 mmol cm-3). Finally, by direct comparison of simulation results with experimental data it isexplained why ‘ordinary’ carbonaceous materials are not efficient quantum sieves. 2009 Journal Article http://hdl.handle.net/20.500.11937/8941 http://stacks.iop.org/JPhysCM/21/144210 IOP Publishing Ltd restricted
spellingShingle Kowalczyk, Poitr
Gauden, P.
Terzyk, A.
Furmaniak, S.
Impact of the carbon pore size and topology on the equilibrium quantum sieving of hydrogen isotopes at zero coverage and finite pressures
title Impact of the carbon pore size and topology on the equilibrium quantum sieving of hydrogen isotopes at zero coverage and finite pressures
title_full Impact of the carbon pore size and topology on the equilibrium quantum sieving of hydrogen isotopes at zero coverage and finite pressures
title_fullStr Impact of the carbon pore size and topology on the equilibrium quantum sieving of hydrogen isotopes at zero coverage and finite pressures
title_full_unstemmed Impact of the carbon pore size and topology on the equilibrium quantum sieving of hydrogen isotopes at zero coverage and finite pressures
title_short Impact of the carbon pore size and topology on the equilibrium quantum sieving of hydrogen isotopes at zero coverage and finite pressures
title_sort impact of the carbon pore size and topology on the equilibrium quantum sieving of hydrogen isotopes at zero coverage and finite pressures
url http://stacks.iop.org/JPhysCM/21/144210
http://hdl.handle.net/20.500.11937/8941