The Reduction of Nickel Slags by Graphite Electrodes using AC and DC Current
The reduction rates of nickel, cobalt and copper oxides from a commercial nickel smelter slag were measured using mainly graphite electrodes in the range 0 -10 volts AC and DC, and at power inputs ranging from zero to 191 watts. The initial slag contained around 0.4% nickel, and 0.1% of both cobalt...