Combined BAC and MIEX pre-treatment of secondary wastewater effluent to reduce fouling of nanofiltration membranes
Biological activated carbon (BAC) and magnetic ion exchange resin (MIEX) were used to pre-treat secondary wastewater effluent (SWWE) and assessed for their capacity to reduce fouling of a nanofiltration membrane. BAC pre-treated water facilitated a lower but a steady flux while MIEX treated water re...