Optical tomography verification for single and mixed modalities

Modelling and experiments are pragmatic methods for verifying the performance of any design. Fundamentally, modelling is the first step to ensure that a design is created according to the desired characteristics. The experimental approach allows the examination of the modelling behaviour in a real e...

Full description

Bibliographic Details
Main Authors: Mohd Muji, Siti Zarina, Abdul Rahim, Ruzairi, Rahiman, Mohd Hafiz Fazalul, Chua , King Lee, Amirulah, Rahman, Ambar, Radzi
Format: Article
Published: Elsevier B.V. 2017
Subjects:
Online Access:http://dx.doi.org/10.1016/j.sna.2016.11.012
http://dx.doi.org/10.1016/j.sna.2016.11.012
id uthm-9333
recordtype eprints
spelling uthm-93332018-08-13T03:16:23Z Optical tomography verification for single and mixed modalities Mohd Muji, Siti Zarina Abdul Rahim, Ruzairi Rahiman, Mohd Hafiz Fazalul Chua , King Lee Amirulah, Rahman Ambar, Radzi QC Physics Modelling and experiments are pragmatic methods for verifying the performance of any design. Fundamentally, modelling is the first step to ensure that a design is created according to the desired characteristics. The experimental approach allows the examination of the modelling behaviour in a real environment and the verification of the design’s correctness. In this research, the accuracy of an optical tomography system is evaluated by comparing the graph pattern generated through modelling and experimental procedures. Both are conducted in two different projections: single and mixed projections called the parallel beam (PB) projection and the mixed projection of parallel and fan beams left and right (MPFBLR) respectively. The evaluations confirm that the experimental and modelled patterns are consistent. This indicates that the developed optical tomography system has the desired characteristics. In this paper, a novel technique of threshold value, called filtered back projection (FBP) using averaging grouping colour (AGC), is presented. It is found that the more complex the object’s location in a pipe, the higher the normalized mean square error (NMSE) and the lower the peak to noise ratio (PSNR). Elsevier B.V. 2017 Article PeerReviewed http://dx.doi.org/10.1016/j.sna.2016.11.012 Mohd Muji, Siti Zarina and Abdul Rahim, Ruzairi and Rahiman, Mohd Hafiz Fazalul and Chua , King Lee and Amirulah, Rahman and Ambar, Radzi (2017) Optical tomography verification for single and mixed modalities. Sensors and Actuators A, 253 . pp. 10-26. ISSN 09244247 http://eprints.uthm.edu.my/9333/
repository_type Digital Repository
institution_category Local University
institution Universiti Tun Hussein Onn Malaysia
building UTHM Institutional Repository
collection Online Access
topic QC Physics
spellingShingle QC Physics
Mohd Muji, Siti Zarina
Abdul Rahim, Ruzairi
Rahiman, Mohd Hafiz Fazalul
Chua , King Lee
Amirulah, Rahman
Ambar, Radzi
Optical tomography verification for single and mixed modalities
description Modelling and experiments are pragmatic methods for verifying the performance of any design. Fundamentally, modelling is the first step to ensure that a design is created according to the desired characteristics. The experimental approach allows the examination of the modelling behaviour in a real environment and the verification of the design’s correctness. In this research, the accuracy of an optical tomography system is evaluated by comparing the graph pattern generated through modelling and experimental procedures. Both are conducted in two different projections: single and mixed projections called the parallel beam (PB) projection and the mixed projection of parallel and fan beams left and right (MPFBLR) respectively. The evaluations confirm that the experimental and modelled patterns are consistent. This indicates that the developed optical tomography system has the desired characteristics. In this paper, a novel technique of threshold value, called filtered back projection (FBP) using averaging grouping colour (AGC), is presented. It is found that the more complex the object’s location in a pipe, the higher the normalized mean square error (NMSE) and the lower the peak to noise ratio (PSNR).
format Article
author Mohd Muji, Siti Zarina
Abdul Rahim, Ruzairi
Rahiman, Mohd Hafiz Fazalul
Chua , King Lee
Amirulah, Rahman
Ambar, Radzi
author_facet Mohd Muji, Siti Zarina
Abdul Rahim, Ruzairi
Rahiman, Mohd Hafiz Fazalul
Chua , King Lee
Amirulah, Rahman
Ambar, Radzi
author_sort Mohd Muji, Siti Zarina
title Optical tomography verification for single and mixed modalities
title_short Optical tomography verification for single and mixed modalities
title_full Optical tomography verification for single and mixed modalities
title_fullStr Optical tomography verification for single and mixed modalities
title_full_unstemmed Optical tomography verification for single and mixed modalities
title_sort optical tomography verification for single and mixed modalities
publisher Elsevier B.V.
publishDate 2017
url http://dx.doi.org/10.1016/j.sna.2016.11.012
http://dx.doi.org/10.1016/j.sna.2016.11.012
first_indexed 2018-09-05T11:49:44Z
last_indexed 2018-09-05T11:49:44Z
_version_ 1610768118459662336