Repaired of fire-damaged concrete-filled double skin steel tubular (CFDST) columns with fiber reinforced polymer (FRP)

Fire is one of the most severe natural disasters that a structure needed to face. Therefore, this study focused on post-fire repair of concrete-filled double skin steel tubular (CFDST) columns using fiber reinforced polymer (FRP). There are two types of repairing scheme that is discussed in this stu...

Full description

Bibliographic Details
Main Authors: Shahidan, Shahiron, Mohd Zuki, Sharifah Salwa, Choong, Kok Keong, J., Jayaprakash
Format: Conference or Workshop Item
Published: 2015
Subjects:
Online Access:http://eprints.uthm.edu.my/7623/
Description
Summary:Fire is one of the most severe natural disasters that a structure needed to face. Therefore, this study focused on post-fire repair of concrete-filled double skin steel tubular (CFDST) columns using fiber reinforced polymer (FRP). There are two types of repairing scheme that is discussed in this study, single and Hybrid FRP. Prior to being repaired, the CFDST columns were subjected to fire following ASTM E-119 standard fire curve until the temperature reached 600°C. Then, the temperature was kept constant for two different exposure times, i.e., 60 minutes, 90 minutes. Both single and Hybrid FRP enhanced the ultimate strength, secant stiffness and Ductility Index (DI) of fire-damaged CFDST columns