Application of FTIR spectroscopy for the determination of virgin coconut oil in binary mixtures with olive oil and palm oil.

Rapid Fourier transform infrared (FTIR) spectroscopy combined with attenuated total reflectance (ATR) was applied for quantitative analysis of virgin coconut oil (VCO) in binary mixtures with olive oil (OO) and palm oil (PO). The spectral bands correlated with VCO, OO, PO; blends of VCO and OO; VCO...

Full description

Bibliographic Details
Main Authors: Rohman, Abdul, Che Man, Yaakob, Ismail, Amin, Hashim, Puziah
Format: Article
Language:English
English
Published: Springer Verlag 2010
Online Access:http://psasir.upm.edu.my/id/eprint/13227/
http://psasir.upm.edu.my/id/eprint/13227/
http://psasir.upm.edu.my/id/eprint/13227/1/Application%20of%20FTIR%20spectroscopy%20for%20the%20determination%20of%20virgin%20coconut%20oil%20in%20binary%20mixtures%20with%20olive%20oil%20and%20palm%20oil.pdf
id upm-13227
recordtype eprints
spelling upm-132272015-11-02T03:01:04Z http://psasir.upm.edu.my/id/eprint/13227/ Application of FTIR spectroscopy for the determination of virgin coconut oil in binary mixtures with olive oil and palm oil. Rohman, Abdul Che Man, Yaakob Ismail, Amin Hashim, Puziah Rapid Fourier transform infrared (FTIR) spectroscopy combined with attenuated total reflectance (ATR) was applied for quantitative analysis of virgin coconut oil (VCO) in binary mixtures with olive oil (OO) and palm oil (PO). The spectral bands correlated with VCO, OO, PO; blends of VCO and OO; VCO and PO were scanned, interpreted, and identified. Two multivariate calibration methods, partial least square (PLS) and principal component regression (PCR), were used to construct the calibration models that correlate between actual and FTIR-predicted values of VCO contents in the mixtures at the FTIR spectral frequencies of 1,120–1,105 and 965–960 cm−1. The calibration models obtained were cross validated using the “leave one out” method. PLS at these frequencies showed the best calibration model, in terms of the highest coefficient of determination (R 2) and the lowest of root mean standard error of calibration (RMSEC) with R 2 = 0.9992 and RMSEC = 0.756, respectively, for VCO in mixture with OO. Meanwhile, the R 2 and RMSEC values obtained for VCO in mixture with PO were 0.9996 and 0.494, respectively. In general, FTIR spectroscopy serves as a suitable technique for determination of VCO in mixture with the other oils. Springer Verlag 2010 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/13227/1/Application%20of%20FTIR%20spectroscopy%20for%20the%20determination%20of%20virgin%20coconut%20oil%20in%20binary%20mixtures%20with%20olive%20oil%20and%20palm%20oil.pdf Rohman, Abdul and Che Man, Yaakob and Ismail, Amin and Hashim, Puziah (2010) Application of FTIR spectroscopy for the determination of virgin coconut oil in binary mixtures with olive oil and palm oil. Journal of the American Oil Chemists' Society, 87 (6). pp. 601-606. ISSN 0003-021X; ESSN:1558-9331 10.1007/s11746-009-1536-7 English
repository_type Digital Repository
institution_category Local University
institution Universiti Putra Malaysia
building UPM Institutional Repository
collection Online Access
language English
English
description Rapid Fourier transform infrared (FTIR) spectroscopy combined with attenuated total reflectance (ATR) was applied for quantitative analysis of virgin coconut oil (VCO) in binary mixtures with olive oil (OO) and palm oil (PO). The spectral bands correlated with VCO, OO, PO; blends of VCO and OO; VCO and PO were scanned, interpreted, and identified. Two multivariate calibration methods, partial least square (PLS) and principal component regression (PCR), were used to construct the calibration models that correlate between actual and FTIR-predicted values of VCO contents in the mixtures at the FTIR spectral frequencies of 1,120–1,105 and 965–960 cm−1. The calibration models obtained were cross validated using the “leave one out” method. PLS at these frequencies showed the best calibration model, in terms of the highest coefficient of determination (R 2) and the lowest of root mean standard error of calibration (RMSEC) with R 2 = 0.9992 and RMSEC = 0.756, respectively, for VCO in mixture with OO. Meanwhile, the R 2 and RMSEC values obtained for VCO in mixture with PO were 0.9996 and 0.494, respectively. In general, FTIR spectroscopy serves as a suitable technique for determination of VCO in mixture with the other oils.
format Article
author Rohman, Abdul
Che Man, Yaakob
Ismail, Amin
Hashim, Puziah
spellingShingle Rohman, Abdul
Che Man, Yaakob
Ismail, Amin
Hashim, Puziah
Application of FTIR spectroscopy for the determination of virgin coconut oil in binary mixtures with olive oil and palm oil.
author_facet Rohman, Abdul
Che Man, Yaakob
Ismail, Amin
Hashim, Puziah
author_sort Rohman, Abdul
title Application of FTIR spectroscopy for the determination of virgin coconut oil in binary mixtures with olive oil and palm oil.
title_short Application of FTIR spectroscopy for the determination of virgin coconut oil in binary mixtures with olive oil and palm oil.
title_full Application of FTIR spectroscopy for the determination of virgin coconut oil in binary mixtures with olive oil and palm oil.
title_fullStr Application of FTIR spectroscopy for the determination of virgin coconut oil in binary mixtures with olive oil and palm oil.
title_full_unstemmed Application of FTIR spectroscopy for the determination of virgin coconut oil in binary mixtures with olive oil and palm oil.
title_sort application of ftir spectroscopy for the determination of virgin coconut oil in binary mixtures with olive oil and palm oil.
publisher Springer Verlag
publishDate 2010
url http://psasir.upm.edu.my/id/eprint/13227/
http://psasir.upm.edu.my/id/eprint/13227/
http://psasir.upm.edu.my/id/eprint/13227/1/Application%20of%20FTIR%20spectroscopy%20for%20the%20determination%20of%20virgin%20coconut%20oil%20in%20binary%20mixtures%20with%20olive%20oil%20and%20palm%20oil.pdf
first_indexed 2018-09-07T13:21:20Z
last_indexed 2018-09-07T13:21:20Z
_version_ 1610955075426975744