A model-based control protocol for transition from ICU to HDU: Robustness analysis
The robustness of a model-based control protocol as a less intensive TGC protocol using insulin Glargine for provision of basal insulin is simulated in this study. To quantify the performance and robustness of the protocol to errors, namely physiological variability and sensor errors, an in-silico M...
Main Authors: | , , , , |
---|---|
Published: |
2018
|
Online Access: | http://dspace.uniten.edu.my/jspui/handle/123456789/9592 |
Summary: | The robustness of a model-based control protocol as a less intensive TGC protocol using insulin Glargine for provision of basal insulin is simulated in this study. To quantify the performance and robustness of the protocol to errors, namely physiological variability and sensor errors, an in-silico Monte Carlo analysis is performed. Actual patient data from Christchurch Hospital, New Zealand were used as virtual trial patients. © 2013 IEEE. |
---|