Power Transformer Fire and Explosion: Causes and Control

An increasing number of failures of power transformers over the world has led to greater interest in building up much needed expertise in electric power transformers, from its design to both preventive and prescribed maintenance. Winding failure is a frequent cause of transformer failure, bushing fa...

Full description

Bibliographic Details
Main Authors: Hoole, P.R.P., Shirley, Anak Rufus, Nurul Izzati, bt Hashim, Mohd Hafiez Izzwan, b Saad, Azfar Satari, b Abdullah, Al-Khalid, Hj Othman, K., Piralaharan, Aravind, CV, Hoole, S.R.H.
Format: Article
Language:English
Published: International Science Press 2017
Subjects:
Online Access:http://ir.unimas.my/20171/
http://ir.unimas.my/20171/
http://ir.unimas.my/20171/1/1499672109%20%28abstrak%29.pdf
id unimas-20171
recordtype eprints
spelling unimas-201712018-04-20T05:48:02Z http://ir.unimas.my/20171/ Power Transformer Fire and Explosion: Causes and Control Hoole, P.R.P. Shirley, Anak Rufus Nurul Izzati, bt Hashim Mohd Hafiez Izzwan, b Saad Azfar Satari, b Abdullah Al-Khalid, Hj Othman K., Piralaharan Aravind, CV Hoole, S.R.H. TK Electrical engineering. Electronics Nuclear engineering An increasing number of failures of power transformers over the world has led to greater interest in building up much needed expertise in electric power transformers, from its design to both preventive and prescribed maintenance. Winding failure is a frequent cause of transformer failure, bushing failure leads of fire and explosion, but it is still uncertain whether the increasing failure of transformers may be related to increasing lightning activity or increasing electric energy of the transient, surge voltages generated by lightning, especially long continuing currents and rate of rise of currents. But there are other important causes as well which need close attention, including wearing out of the contact points of tap changers in power generating and substation transformers, and poor maintenance of transformer oil. This paper seeks to review some of the well-known causes that lead to transformer fire and explosion, and highlights the important parts of the power transformer that need careful selection, installation, maintenance and condition monitoring. Moreover the containment of fires and measures that help to prevent transformer explosions in case of transformer fires are also discussed. Keywords: Embedded systems, Smart Antenna; Adaptive Array; Artificial Neural Network. International Science Press 2017 Article NonPeerReviewed text en http://ir.unimas.my/20171/1/1499672109%20%28abstrak%29.pdf Hoole, P.R.P. and Shirley, Anak Rufus and Nurul Izzati, bt Hashim and Mohd Hafiez Izzwan, b Saad and Azfar Satari, b Abdullah and Al-Khalid, Hj Othman and K., Piralaharan and Aravind, CV and Hoole, S.R.H. (2017) Power Transformer Fire and Explosion: Causes and Control. International Journal of Control Theory and Applications, 10 (16). pp. 211-219. ISSN 0974-5572 http://serialsjournals.com/journal-detail.php?journals_id=268
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Sarawak
building UNIMAS Institutional Repository
collection Online Access
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Hoole, P.R.P.
Shirley, Anak Rufus
Nurul Izzati, bt Hashim
Mohd Hafiez Izzwan, b Saad
Azfar Satari, b Abdullah
Al-Khalid, Hj Othman
K., Piralaharan
Aravind, CV
Hoole, S.R.H.
Power Transformer Fire and Explosion: Causes and Control
description An increasing number of failures of power transformers over the world has led to greater interest in building up much needed expertise in electric power transformers, from its design to both preventive and prescribed maintenance. Winding failure is a frequent cause of transformer failure, bushing failure leads of fire and explosion, but it is still uncertain whether the increasing failure of transformers may be related to increasing lightning activity or increasing electric energy of the transient, surge voltages generated by lightning, especially long continuing currents and rate of rise of currents. But there are other important causes as well which need close attention, including wearing out of the contact points of tap changers in power generating and substation transformers, and poor maintenance of transformer oil. This paper seeks to review some of the well-known causes that lead to transformer fire and explosion, and highlights the important parts of the power transformer that need careful selection, installation, maintenance and condition monitoring. Moreover the containment of fires and measures that help to prevent transformer explosions in case of transformer fires are also discussed. Keywords: Embedded systems, Smart Antenna; Adaptive Array; Artificial Neural Network.
format Article
author Hoole, P.R.P.
Shirley, Anak Rufus
Nurul Izzati, bt Hashim
Mohd Hafiez Izzwan, b Saad
Azfar Satari, b Abdullah
Al-Khalid, Hj Othman
K., Piralaharan
Aravind, CV
Hoole, S.R.H.
author_facet Hoole, P.R.P.
Shirley, Anak Rufus
Nurul Izzati, bt Hashim
Mohd Hafiez Izzwan, b Saad
Azfar Satari, b Abdullah
Al-Khalid, Hj Othman
K., Piralaharan
Aravind, CV
Hoole, S.R.H.
author_sort Hoole, P.R.P.
title Power Transformer Fire and Explosion: Causes and Control
title_short Power Transformer Fire and Explosion: Causes and Control
title_full Power Transformer Fire and Explosion: Causes and Control
title_fullStr Power Transformer Fire and Explosion: Causes and Control
title_full_unstemmed Power Transformer Fire and Explosion: Causes and Control
title_sort power transformer fire and explosion: causes and control
publisher International Science Press
publishDate 2017
url http://ir.unimas.my/20171/
http://ir.unimas.my/20171/
http://ir.unimas.my/20171/1/1499672109%20%28abstrak%29.pdf
first_indexed 2018-09-06T16:54:11Z
last_indexed 2018-09-06T16:54:11Z
_version_ 1610877870157070336