Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate

Background. The use of locking plates has gained popularity to treat proximal humeral fractures. However, the complication rates remain high. Biomechanical study suggested that subchondral screw-tip abutment significantly increased the stability of plant. We present a simple method to obtain the pr...

Full description

Bibliographic Details
Main Authors: Jin, Lin, Guo, Jialiang, Guo, Junfei, Yin, Yingchao, Hou, Zhiyong, Zhang, Yingze
Format: Online
Language:English
Published: Hindawi Publishing Corporation 2016
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5126400/
id pubmed-5126400
recordtype oai_dc
spelling pubmed-51264002016-12-14 Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate Jin, Lin Guo, Jialiang Guo, Junfei Yin, Yingchao Hou, Zhiyong Zhang, Yingze Clinical Study Background. The use of locking plates has gained popularity to treat proximal humeral fractures. However, the complication rates remain high. Biomechanical study suggested that subchondral screw-tip abutment significantly increased the stability of plant. We present a simple method to obtain the proper screw length through the depth gauge in elderly patients and compared the clinical effects with traditional measuring method. Methods. 40 patients were separated into two groups according to the two surgical methods: the probing method with depth gauge and the traditional measuring method. The intraoperative indexes and postoperative complications were recorded. The Constant and Murley score was used for the functional assessment in the 12th month. Results. Operative time and intraoperative blood loss indicated no statistical differences. X-ray exposure time and the patients with screw path penetrating the articular cartilage significantly differed. Postoperative complications and Constant and Murley score showed no statistical differences. Conclusions. Probing method with depth gauge is an appropriate alternative to determine the screw length, which can make the screw-tip adjoin the subchondral bone and keep the articular surface of humeral head intact and at the same time effectively avoid frequent X-ray fluoroscopy and adjusting the screws. Hindawi Publishing Corporation 2016 2016-11-15 /pmc/articles/PMC5126400/ /pubmed/27975055 http://dx.doi.org/10.1155/2016/5898161 Text en Copyright © 2016 Lin Jin et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
repository_type Open Access Journal
institution_category Foreign Institution
institution US National Center for Biotechnology Information
building NCBI PubMed
collection Online Access
language English
format Online
author Jin, Lin
Guo, Jialiang
Guo, Junfei
Yin, Yingchao
Hou, Zhiyong
Zhang, Yingze
spellingShingle Jin, Lin
Guo, Jialiang
Guo, Junfei
Yin, Yingchao
Hou, Zhiyong
Zhang, Yingze
Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate
author_facet Jin, Lin
Guo, Jialiang
Guo, Junfei
Yin, Yingchao
Hou, Zhiyong
Zhang, Yingze
author_sort Jin, Lin
title Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate
title_short Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate
title_full Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate
title_fullStr Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate
title_full_unstemmed Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate
title_sort clinical effects of the probing method with depth gauge for determining the screw depth of locking proximal humeral plate
description Background. The use of locking plates has gained popularity to treat proximal humeral fractures. However, the complication rates remain high. Biomechanical study suggested that subchondral screw-tip abutment significantly increased the stability of plant. We present a simple method to obtain the proper screw length through the depth gauge in elderly patients and compared the clinical effects with traditional measuring method. Methods. 40 patients were separated into two groups according to the two surgical methods: the probing method with depth gauge and the traditional measuring method. The intraoperative indexes and postoperative complications were recorded. The Constant and Murley score was used for the functional assessment in the 12th month. Results. Operative time and intraoperative blood loss indicated no statistical differences. X-ray exposure time and the patients with screw path penetrating the articular cartilage significantly differed. Postoperative complications and Constant and Murley score showed no statistical differences. Conclusions. Probing method with depth gauge is an appropriate alternative to determine the screw length, which can make the screw-tip adjoin the subchondral bone and keep the articular surface of humeral head intact and at the same time effectively avoid frequent X-ray fluoroscopy and adjusting the screws.
publisher Hindawi Publishing Corporation
publishDate 2016
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5126400/
_version_ 1613744150834839552