Endoscopically visible steam pop during high-energy laser pulmonary vein ablation

A 58-year-old woman with atrial fibrillation underwent laser balloon ablation at our centre. During 12 W ablation in the left superior pulmonary vein, a sudden steam pop was witnessed with displacement of the balloon catheter. Visualisation of the pulmonary vein antrum showed a red discolouration at...

Full description

Bibliographic Details
Main Authors: Gal, P., Smit, J.J.J, Elvan, A.
Format: Online
Language:English
Published: Bohn Stafleu van Loghum 2015
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4547946/