Percutaneous Aortic Balloon Valvuloplasty and Intracardiac Adrenaline in Electromechanical Dissociation as Bridge to Transcatheter Aortic Valve Implantation

This report describes an emergent balloon aortic valvuloplasty (BAV) procedure performed under cardiopulmonary resuscitation in a 79-year-old man with severe symptomatic aortic stenosis (mean gradient 78 mm Hg, valve area 0.71 cm2, and left ventricular ejection fraction 40%) awaiting surgery and who...

Full description

Bibliographic Details
Main Authors: Chaara, Jawad, Meier, Pascal, Ellenberger, Christophe, Gasche, Yvan, Bendjelid, Karim, Noble, Stephane, Roffi, Marco
Format: Online
Language:English
Published: Wolters Kluwer Health 2015
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4504577/
id pubmed-4504577
recordtype oai_dc
spelling pubmed-45045772015-08-05 Percutaneous Aortic Balloon Valvuloplasty and Intracardiac Adrenaline in Electromechanical Dissociation as Bridge to Transcatheter Aortic Valve Implantation Chaara, Jawad Meier, Pascal Ellenberger, Christophe Gasche, Yvan Bendjelid, Karim Noble, Stephane Roffi, Marco 3400 This report describes an emergent balloon aortic valvuloplasty (BAV) procedure performed under cardiopulmonary resuscitation in a 79-year-old man with severe symptomatic aortic stenosis (mean gradient 78 mm Hg, valve area 0.71 cm2, and left ventricular ejection fraction 40%) awaiting surgery and who was admitted for heart failure rapidly evolving to cardiogenic shock and multiorgan failure. Decision was made to perform emergent BAV. After crossing the valve with a 6 French catheter, the patient developed an electromechanical dissociation confirmed at transesophageal echocardiography and cardiac arrest. Manual chest compressions were initiated along with the application of high doses of intravenous adrenaline, and BAV was performed under ongoing resuscitation. Despite BAV, transoesophageal echocardiography demonstrated no cardiac activity. At this point, it was decided to advance a pigtail catheter over the wire already in place in the left ventricle and to inject intracardiac adrenaline (1 mg, followed by 5 mg). Left ventricular contraction progressively resumed and, in the absence of aortic regurgitation, an intraaortic balloon pump was inserted. The patient could be weaned from intraaortic balloon pump and vasopressors on day 1, extubated on day 6, and recovered from multiorgan failure. In the absence of neurologic deficits, he underwent uneventful transcatheter aortic valve implantation on day 12 and was discharged to a cardiac rehabilitation program on day 30. At 3-month follow-up, he reported dyspnea NYHA class II as the only symptom. Wolters Kluwer Health 2015-07-02 /pmc/articles/PMC4504577/ /pubmed/26131825 http://dx.doi.org/10.1097/MD.0000000000001061 Text en Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
repository_type Open Access Journal
institution_category Foreign Institution
institution US National Center for Biotechnology Information
building NCBI PubMed
collection Online Access
language English
format Online
author Chaara, Jawad
Meier, Pascal
Ellenberger, Christophe
Gasche, Yvan
Bendjelid, Karim
Noble, Stephane
Roffi, Marco
spellingShingle Chaara, Jawad
Meier, Pascal
Ellenberger, Christophe
Gasche, Yvan
Bendjelid, Karim
Noble, Stephane
Roffi, Marco
Percutaneous Aortic Balloon Valvuloplasty and Intracardiac Adrenaline in Electromechanical Dissociation as Bridge to Transcatheter Aortic Valve Implantation
author_facet Chaara, Jawad
Meier, Pascal
Ellenberger, Christophe
Gasche, Yvan
Bendjelid, Karim
Noble, Stephane
Roffi, Marco
author_sort Chaara, Jawad
title Percutaneous Aortic Balloon Valvuloplasty and Intracardiac Adrenaline in Electromechanical Dissociation as Bridge to Transcatheter Aortic Valve Implantation
title_short Percutaneous Aortic Balloon Valvuloplasty and Intracardiac Adrenaline in Electromechanical Dissociation as Bridge to Transcatheter Aortic Valve Implantation
title_full Percutaneous Aortic Balloon Valvuloplasty and Intracardiac Adrenaline in Electromechanical Dissociation as Bridge to Transcatheter Aortic Valve Implantation
title_fullStr Percutaneous Aortic Balloon Valvuloplasty and Intracardiac Adrenaline in Electromechanical Dissociation as Bridge to Transcatheter Aortic Valve Implantation
title_full_unstemmed Percutaneous Aortic Balloon Valvuloplasty and Intracardiac Adrenaline in Electromechanical Dissociation as Bridge to Transcatheter Aortic Valve Implantation
title_sort percutaneous aortic balloon valvuloplasty and intracardiac adrenaline in electromechanical dissociation as bridge to transcatheter aortic valve implantation
description This report describes an emergent balloon aortic valvuloplasty (BAV) procedure performed under cardiopulmonary resuscitation in a 79-year-old man with severe symptomatic aortic stenosis (mean gradient 78 mm Hg, valve area 0.71 cm2, and left ventricular ejection fraction 40%) awaiting surgery and who was admitted for heart failure rapidly evolving to cardiogenic shock and multiorgan failure. Decision was made to perform emergent BAV. After crossing the valve with a 6 French catheter, the patient developed an electromechanical dissociation confirmed at transesophageal echocardiography and cardiac arrest. Manual chest compressions were initiated along with the application of high doses of intravenous adrenaline, and BAV was performed under ongoing resuscitation. Despite BAV, transoesophageal echocardiography demonstrated no cardiac activity. At this point, it was decided to advance a pigtail catheter over the wire already in place in the left ventricle and to inject intracardiac adrenaline (1 mg, followed by 5 mg). Left ventricular contraction progressively resumed and, in the absence of aortic regurgitation, an intraaortic balloon pump was inserted. The patient could be weaned from intraaortic balloon pump and vasopressors on day 1, extubated on day 6, and recovered from multiorgan failure. In the absence of neurologic deficits, he underwent uneventful transcatheter aortic valve implantation on day 12 and was discharged to a cardiac rehabilitation program on day 30. At 3-month follow-up, he reported dyspnea NYHA class II as the only symptom.
publisher Wolters Kluwer Health
publishDate 2015
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4504577/
_version_ 1613248676098998272