Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study

Long acquisition times lead to image artifacts in thoracic C-arm CT. Motion blur caused by respiratory motion leads to decreased image quality in many clinical applications. We introduce an image-based method to estimate and compensate respiratory motion in C-arm CT based on diaphragm motion. In ord...

Full description

Bibliographic Details
Main Authors: Bögel, Marco, Hofmann, Hannes G., Hornegger, Joachim, Fahrig, Rebecca, Britzen, Stefan, Maier, Andreas
Format: Online
Language:English
Published: Hindawi Publishing Corporation 2013
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3690260/
id pubmed-3690260
recordtype oai_dc
spelling pubmed-36902602013-07-09 Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study Bögel, Marco Hofmann, Hannes G. Hornegger, Joachim Fahrig, Rebecca Britzen, Stefan Maier, Andreas Research Article Long acquisition times lead to image artifacts in thoracic C-arm CT. Motion blur caused by respiratory motion leads to decreased image quality in many clinical applications. We introduce an image-based method to estimate and compensate respiratory motion in C-arm CT based on diaphragm motion. In order to estimate respiratory motion, we track the contour of the diaphragm in the projection image sequence. Using a motion corrected triangulation approach on the diaphragm vertex, we are able to estimate a motion signal. The estimated motion signal is used to compensate for respiratory motion in the target region, for example, heart or lungs. First, we evaluated our approach in a simulation study using XCAT. As ground truth data was available, a quantitative evaluation was performed. We observed an improvement of about 14% using the structural similarity index. In a real phantom study, using the artiCHEST phantom, we investigated the visibility of bronchial tubes in a porcine lung. Compared to an uncompensated scan, the visibility of bronchial structures is improved drastically. Preliminary results indicate that this kind of motion compensation can deliver a first step in reconstruction image quality improvement. Compared to ground truth data, image quality is still considerably reduced. Hindawi Publishing Corporation 2013 2013-06-06 /pmc/articles/PMC3690260/ /pubmed/23840198 http://dx.doi.org/10.1155/2013/520540 Text en Copyright © 2013 Marco Bögel et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
repository_type Open Access Journal
institution_category Foreign Institution
institution US National Center for Biotechnology Information
building NCBI PubMed
collection Online Access
language English
format Online
author Bögel, Marco
Hofmann, Hannes G.
Hornegger, Joachim
Fahrig, Rebecca
Britzen, Stefan
Maier, Andreas
spellingShingle Bögel, Marco
Hofmann, Hannes G.
Hornegger, Joachim
Fahrig, Rebecca
Britzen, Stefan
Maier, Andreas
Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study
author_facet Bögel, Marco
Hofmann, Hannes G.
Hornegger, Joachim
Fahrig, Rebecca
Britzen, Stefan
Maier, Andreas
author_sort Bögel, Marco
title Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study
title_short Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study
title_full Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study
title_fullStr Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study
title_full_unstemmed Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study
title_sort respiratory motion compensation using diaphragm tracking for cone-beam c-arm ct: a simulation and a phantom study
description Long acquisition times lead to image artifacts in thoracic C-arm CT. Motion blur caused by respiratory motion leads to decreased image quality in many clinical applications. We introduce an image-based method to estimate and compensate respiratory motion in C-arm CT based on diaphragm motion. In order to estimate respiratory motion, we track the contour of the diaphragm in the projection image sequence. Using a motion corrected triangulation approach on the diaphragm vertex, we are able to estimate a motion signal. The estimated motion signal is used to compensate for respiratory motion in the target region, for example, heart or lungs. First, we evaluated our approach in a simulation study using XCAT. As ground truth data was available, a quantitative evaluation was performed. We observed an improvement of about 14% using the structural similarity index. In a real phantom study, using the artiCHEST phantom, we investigated the visibility of bronchial tubes in a porcine lung. Compared to an uncompensated scan, the visibility of bronchial structures is improved drastically. Preliminary results indicate that this kind of motion compensation can deliver a first step in reconstruction image quality improvement. Compared to ground truth data, image quality is still considerably reduced.
publisher Hindawi Publishing Corporation
publishDate 2013
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3690260/
_version_ 1611988830684971008