The Test-Retest Reliability of Anatomical Co-Ordinate Axes Definition for the Quantification of Lower Extremity Kinematics During Running

Three-dimensional (3-D) kinematic analyses are used widely in both sport and clinical examinations. However, this procedure depends on reliable palpation of anatomical landmarks and mal-positioning of markers between sessions may result in improperly defined segment co-ordinate system axes which wil...

Full description

Bibliographic Details
Main Authors: Sinclair, Jonathan, Taylor, Paul John, Greenhalgh, Andrew, Edmundson, Christopher James, Brooks, Darrell, Hobbs, Sarah Jane
Format: Online
Language:English
Published: Akademia Wychowania Fizycznego w Katowicach 2012
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3588698/
id pubmed-3588698
recordtype oai_dc
spelling pubmed-35886982013-03-13 The Test-Retest Reliability of Anatomical Co-Ordinate Axes Definition for the Quantification of Lower Extremity Kinematics During Running Sinclair, Jonathan Taylor, Paul John Greenhalgh, Andrew Edmundson, Christopher James Brooks, Darrell Hobbs, Sarah Jane Research Article Three-dimensional (3-D) kinematic analyses are used widely in both sport and clinical examinations. However, this procedure depends on reliable palpation of anatomical landmarks and mal-positioning of markers between sessions may result in improperly defined segment co-ordinate system axes which will produce in-consistent joint rotations. This had led some to question the efficacy of this technique. The aim of the current investigation was to assess the reliability of the anatomical frame definition when quantifying 3-D kinematics of the lower extremities during running. Ten participants completed five successful running trials at 4.0 m·s−1 ± 5%. 3-D angular joint kinematics parameters from the hip, knee and ankle were collected using an eight camera motion analysis system. Two static calibration trials were captured. The first (test) was conducted prior to the running trials following which anatomical landmarks were removed. The second was obtained following completion of the running trials where anatomical landmarks were re-positioned (retest). Paired samples t-tests were used to compare 3-D kinematic parameters quantified using the two static trials, and intraclass correlations were employed to examine the similarities between the sagittal, coronal and transverse plane waveforms. The results indicate that no significant (p>0.05) differences were found between test and retest 3-D kinematic parameters and strong (R2≥0.87) correlations were observed between test and retest waveforms. Based on the results obtained from this investigation, it appears that the anatomical co-ordinate axes of the lower extremities can be defined reliably thus confirming the efficacy of studies using this technique. Akademia Wychowania Fizycznego w Katowicach 2012-12-30 /pmc/articles/PMC3588698/ /pubmed/23487393 http://dx.doi.org/10.2478/v10078-012-0075-8 Text en © Editorial Committee of Journal of Human Kinetics http://creativecommons.org/licenses/by/3.0 This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
repository_type Open Access Journal
institution_category Foreign Institution
institution US National Center for Biotechnology Information
building NCBI PubMed
collection Online Access
language English
format Online
author Sinclair, Jonathan
Taylor, Paul John
Greenhalgh, Andrew
Edmundson, Christopher James
Brooks, Darrell
Hobbs, Sarah Jane
spellingShingle Sinclair, Jonathan
Taylor, Paul John
Greenhalgh, Andrew
Edmundson, Christopher James
Brooks, Darrell
Hobbs, Sarah Jane
The Test-Retest Reliability of Anatomical Co-Ordinate Axes Definition for the Quantification of Lower Extremity Kinematics During Running
author_facet Sinclair, Jonathan
Taylor, Paul John
Greenhalgh, Andrew
Edmundson, Christopher James
Brooks, Darrell
Hobbs, Sarah Jane
author_sort Sinclair, Jonathan
title The Test-Retest Reliability of Anatomical Co-Ordinate Axes Definition for the Quantification of Lower Extremity Kinematics During Running
title_short The Test-Retest Reliability of Anatomical Co-Ordinate Axes Definition for the Quantification of Lower Extremity Kinematics During Running
title_full The Test-Retest Reliability of Anatomical Co-Ordinate Axes Definition for the Quantification of Lower Extremity Kinematics During Running
title_fullStr The Test-Retest Reliability of Anatomical Co-Ordinate Axes Definition for the Quantification of Lower Extremity Kinematics During Running
title_full_unstemmed The Test-Retest Reliability of Anatomical Co-Ordinate Axes Definition for the Quantification of Lower Extremity Kinematics During Running
title_sort test-retest reliability of anatomical co-ordinate axes definition for the quantification of lower extremity kinematics during running
description Three-dimensional (3-D) kinematic analyses are used widely in both sport and clinical examinations. However, this procedure depends on reliable palpation of anatomical landmarks and mal-positioning of markers between sessions may result in improperly defined segment co-ordinate system axes which will produce in-consistent joint rotations. This had led some to question the efficacy of this technique. The aim of the current investigation was to assess the reliability of the anatomical frame definition when quantifying 3-D kinematics of the lower extremities during running. Ten participants completed five successful running trials at 4.0 m·s−1 ± 5%. 3-D angular joint kinematics parameters from the hip, knee and ankle were collected using an eight camera motion analysis system. Two static calibration trials were captured. The first (test) was conducted prior to the running trials following which anatomical landmarks were removed. The second was obtained following completion of the running trials where anatomical landmarks were re-positioned (retest). Paired samples t-tests were used to compare 3-D kinematic parameters quantified using the two static trials, and intraclass correlations were employed to examine the similarities between the sagittal, coronal and transverse plane waveforms. The results indicate that no significant (p>0.05) differences were found between test and retest 3-D kinematic parameters and strong (R2≥0.87) correlations were observed between test and retest waveforms. Based on the results obtained from this investigation, it appears that the anatomical co-ordinate axes of the lower extremities can be defined reliably thus confirming the efficacy of studies using this technique.
publisher Akademia Wychowania Fizycznego w Katowicach
publishDate 2012
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3588698/
_version_ 1611959664527802368