Corrosion of cast Stellite-3 analogue in simulated PWR conditions
Wear resistant alloys are required for deployment of pressurised water reactor primary circuits and in this context, the corrosion behaviour of a cast cobalt-based alloy following exposure for 30 days in lithiated water at 300°C was investigated. Corrosion of the surface was observed, re...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English English English English |
Published: |
Elsevier
2018
|
Online Access: | http://eprints.nottingham.ac.uk/52222/ http://eprints.nottingham.ac.uk/52222/ http://eprints.nottingham.ac.uk/52222/ http://eprints.nottingham.ac.uk/52222/1/Corrosion%20of%20cast%20Stellite-3%20analogue%20in%20simulated%20PWR%20conditions_.pdf http://eprints.nottingham.ac.uk/52222/2/Figure%20tables.pdf http://eprints.nottingham.ac.uk/52222/3/Graphical%20abstract.pdf http://eprints.nottingham.ac.uk/52222/4/Highlights.pdf |