Fabrication of hip and pelvis part for designing acetabular implant by using Fused Deposition Modeling (FDM) machine

The purpose of this research is to fabricate the hip and pelvis part for designing the acetabular implant by using Fused Deposition Modeling (FDM) technique. The methodology of this research is begin by converting the 2D image of CT into 3D image through Invesalius 3.0 software. Then the 3D image is...

Full description

Bibliographic Details
Main Authors: Wan Yusoff, Wan Ahmad Yusmawiza, Zakariah, Nur Zawanah, Abdullah, Nurshafika, Ani, Mohd Hanafi, Mohd. Mustafah, Yasir
Format: Article
Language:English
Published: Trans Tech Publications, Switzerland 2014
Subjects:
Online Access:http://irep.iium.edu.my/36001/
http://irep.iium.edu.my/36001/
http://irep.iium.edu.my/36001/
http://irep.iium.edu.my/36001/1/10._Fabrication_of_Hip_and_Pelvis_Part_for_Designing_Acetabular_Implant_by_Using_Fused_Deposition_Modeling_%28FDM%29_Machine.pdf
id iium-36001
recordtype eprints
spelling iium-360012018-06-20T07:31:55Z http://irep.iium.edu.my/36001/ Fabrication of hip and pelvis part for designing acetabular implant by using Fused Deposition Modeling (FDM) machine Wan Yusoff, Wan Ahmad Yusmawiza Zakariah, Nur Zawanah Abdullah, Nurshafika Ani, Mohd Hanafi Mohd. Mustafah, Yasir T Technology (General) The purpose of this research is to fabricate the hip and pelvis part for designing the acetabular implant by using Fused Deposition Modeling (FDM) technique. The methodology of this research is begin by converting the 2D image of CT into 3D image through Invesalius 3.0 software. Then the 3D image is converted to .stl format and exported to FDM machine for fabrication purpose. The finish prototype of 3D biomodel replica is evaluated in order to define the problem face by the patient. Also, the dimensional accuracy is measured between 3D replica model and 3D virtual model. Based on the result of 3D biomodel, the ball joint of the femur on the right side is dislocating from its original position because of the fracture occur on acetabular socket. The implant for acetabular fracture is design by using CATIA software and the design must ensure to be fit with the fracture area. Therefore, this study has contributed to medical area especially in Malaysia in improving patient specific preoperative planning and giving better visualization information of the fracture. Trans Tech Publications, Switzerland 2014-02 Article PeerReviewed application/pdf en http://irep.iium.edu.my/36001/1/10._Fabrication_of_Hip_and_Pelvis_Part_for_Designing_Acetabular_Implant_by_Using_Fused_Deposition_Modeling_%28FDM%29_Machine.pdf Wan Yusoff, Wan Ahmad Yusmawiza and Zakariah, Nur Zawanah and Abdullah, Nurshafika and Ani, Mohd Hanafi and Mohd. Mustafah, Yasir (2014) Fabrication of hip and pelvis part for designing acetabular implant by using Fused Deposition Modeling (FDM) machine. Advanced Materials Research, 875-87. pp. 1235-1238. ISSN 1022-6680 http://www.scientific.net/AMR.875-877.1235 10.4028/www.scientific.net/AMR.875-877.1235
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic T Technology (General)
spellingShingle T Technology (General)
Wan Yusoff, Wan Ahmad Yusmawiza
Zakariah, Nur Zawanah
Abdullah, Nurshafika
Ani, Mohd Hanafi
Mohd. Mustafah, Yasir
Fabrication of hip and pelvis part for designing acetabular implant by using Fused Deposition Modeling (FDM) machine
description The purpose of this research is to fabricate the hip and pelvis part for designing the acetabular implant by using Fused Deposition Modeling (FDM) technique. The methodology of this research is begin by converting the 2D image of CT into 3D image through Invesalius 3.0 software. Then the 3D image is converted to .stl format and exported to FDM machine for fabrication purpose. The finish prototype of 3D biomodel replica is evaluated in order to define the problem face by the patient. Also, the dimensional accuracy is measured between 3D replica model and 3D virtual model. Based on the result of 3D biomodel, the ball joint of the femur on the right side is dislocating from its original position because of the fracture occur on acetabular socket. The implant for acetabular fracture is design by using CATIA software and the design must ensure to be fit with the fracture area. Therefore, this study has contributed to medical area especially in Malaysia in improving patient specific preoperative planning and giving better visualization information of the fracture.
format Article
author Wan Yusoff, Wan Ahmad Yusmawiza
Zakariah, Nur Zawanah
Abdullah, Nurshafika
Ani, Mohd Hanafi
Mohd. Mustafah, Yasir
author_facet Wan Yusoff, Wan Ahmad Yusmawiza
Zakariah, Nur Zawanah
Abdullah, Nurshafika
Ani, Mohd Hanafi
Mohd. Mustafah, Yasir
author_sort Wan Yusoff, Wan Ahmad Yusmawiza
title Fabrication of hip and pelvis part for designing acetabular implant by using Fused Deposition Modeling (FDM) machine
title_short Fabrication of hip and pelvis part for designing acetabular implant by using Fused Deposition Modeling (FDM) machine
title_full Fabrication of hip and pelvis part for designing acetabular implant by using Fused Deposition Modeling (FDM) machine
title_fullStr Fabrication of hip and pelvis part for designing acetabular implant by using Fused Deposition Modeling (FDM) machine
title_full_unstemmed Fabrication of hip and pelvis part for designing acetabular implant by using Fused Deposition Modeling (FDM) machine
title_sort fabrication of hip and pelvis part for designing acetabular implant by using fused deposition modeling (fdm) machine
publisher Trans Tech Publications, Switzerland
publishDate 2014
url http://irep.iium.edu.my/36001/
http://irep.iium.edu.my/36001/
http://irep.iium.edu.my/36001/
http://irep.iium.edu.my/36001/1/10._Fabrication_of_Hip_and_Pelvis_Part_for_Designing_Acetabular_Implant_by_Using_Fused_Deposition_Modeling_%28FDM%29_Machine.pdf
first_indexed 2018-09-07T05:44:20Z
last_indexed 2018-09-07T05:44:20Z
_version_ 1610926323813842944