A comparative study on work surface hardness EDMed by Ta-C powder compacted and copper electrodes

Abstract. Tantalum-carbide and solid copper electrodes were used to EDM mild steel. Current, spark on-time and off-time were taken as the machining variables. It was found that work surface hardness increases while machining with high current and on-time. However, increase in spark off-time results...

Full description

Bibliographic Details
Main Authors: Khan, Ahsan Ali, Nazi Nadin, Mohd Faiz, Mohd Hambiyah, Mohammad Azhadi
Format: Book Chapter
Language:English
Published: International Islamic University Malaysia 2011
Subjects:
Online Access:http://irep.iium.edu.my/25556/
http://irep.iium.edu.my/25556/
http://irep.iium.edu.my/25556/2/Chapter_12.pdf
Description
Summary:Abstract. Tantalum-carbide and solid copper electrodes were used to EDM mild steel. Current, spark on-time and off-time were taken as the machining variables. It was found that work surface hardness increases while machining with high current and on-time. However, increase in spark off-time results decrease in work surface hardness. It was also found that the surface machined with pure copper electrodes is harder than that machined by tantalum-carbide powder metallurgy compacted electrodes.