Analysis of polychlorinated biphenyls in sewage sludge using supercritical carbon dioxide and subcritical water extraction

Extractions of polychlorinated biphenyls (PCBs) for sewage sludge are often time consuming and involved the use of large volume of organic solvents. In this study, a supercritical fluid carbon dioxide (SFCO2) extraction and subcritical water extraction (SWE) were developed with the aim of overcoming...

Full description

Bibliographic Details
Main Author: Ab. Halim, Ahmad Zamani
Format: Thesis
Language:English
Published: 2007
Subjects:
Online Access:http://eprints.utm.my/9825/
http://eprints.utm.my/9825/1/AhmadZamaniHalimMFS2007.pdf
_version_ 1848891949038174208
author Ab. Halim, Ahmad Zamani
author_facet Ab. Halim, Ahmad Zamani
author_sort Ab. Halim, Ahmad Zamani
building UTeM Institutional Repository
collection Online Access
description Extractions of polychlorinated biphenyls (PCBs) for sewage sludge are often time consuming and involved the use of large volume of organic solvents. In this study, a supercritical fluid carbon dioxide (SFCO2) extraction and subcritical water extraction (SWE) were developed with the aim of overcoming the disadvantages associated with the conventional Soxhlet extraction. The SFE conditions utilised extraction temperature of 60oC, extraction pressure of 200 bar, 15% methanol as cosolvent, extraction flow rate at 2.0 mL/min, 30 minute extraction and n-hexane as the analyte trapping solvent for PCBs extraction from sludge. A lab-made SWE extraction system was successfully developed for the dynamic SWE of PCBs from sludge samples. For the SWE, the optimized condition employed an extraction temperature of 250oC, extraction pressure of 50 bar, 1 min static followed by 10 min dynamic extraction and analyte collection in dichloromethane. Both the SFCO2 extraction and SWE showed good PCB recoveries (50 to 99%) compared to Soxhlet extraction (52 to 75% PCB recoveries). Comparison of PCBs extracted with Soxhlet extraction revealed that SFCO2 extraction and SWE to be fast, easy, and environmentally clean techniques. From the two extraction methods investigated, it was clear that the SFCO2 technique was better in terms of recovery, good reproducibility and speed of analysis compared to the SWE method and was therefore chosen as the method of choice for the analysis of real sludge samples. The PCBs under study (PCB 28, 52, 101, 118, 138, 153 and 180) when analysed using gas chromatography electron capture detector gave low detection limit in the range of 0.016 to 0.048 µg/mL. The concentration of PCBs in sludge samples extracted using SFCO2 were in the range of 31.2 to 82.0 µg/kg as compared to that using Soxhlet extraction with PCB levels from 20.2 to 60.1 µg/kg. The characterization of sludge samples from other aspects was also carried out. The sludge samples showed slightly acidic pH values ranging from 4.3 to 6.6. All samples were found to be chemically stable and the percentages of nutrient (nitrogen, phosphorus and potassium) were in the range of 0.059 to 0.98%, 0.05 to 0.15% and 0.12 to 0.16%, respectively. Heavy metal studies showed that metal content in municipal sewage sludge samples were below the United States Environmental Protection Agency limit.
first_indexed 2025-11-15T21:06:05Z
format Thesis
id utm-9825
institution Universiti Teknologi Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T21:06:05Z
publishDate 2007
recordtype eprints
repository_type Digital Repository
spelling utm-98252018-08-26T04:50:09Z http://eprints.utm.my/9825/ Analysis of polychlorinated biphenyls in sewage sludge using supercritical carbon dioxide and subcritical water extraction Ab. Halim, Ahmad Zamani QD Chemistry Extractions of polychlorinated biphenyls (PCBs) for sewage sludge are often time consuming and involved the use of large volume of organic solvents. In this study, a supercritical fluid carbon dioxide (SFCO2) extraction and subcritical water extraction (SWE) were developed with the aim of overcoming the disadvantages associated with the conventional Soxhlet extraction. The SFE conditions utilised extraction temperature of 60oC, extraction pressure of 200 bar, 15% methanol as cosolvent, extraction flow rate at 2.0 mL/min, 30 minute extraction and n-hexane as the analyte trapping solvent for PCBs extraction from sludge. A lab-made SWE extraction system was successfully developed for the dynamic SWE of PCBs from sludge samples. For the SWE, the optimized condition employed an extraction temperature of 250oC, extraction pressure of 50 bar, 1 min static followed by 10 min dynamic extraction and analyte collection in dichloromethane. Both the SFCO2 extraction and SWE showed good PCB recoveries (50 to 99%) compared to Soxhlet extraction (52 to 75% PCB recoveries). Comparison of PCBs extracted with Soxhlet extraction revealed that SFCO2 extraction and SWE to be fast, easy, and environmentally clean techniques. From the two extraction methods investigated, it was clear that the SFCO2 technique was better in terms of recovery, good reproducibility and speed of analysis compared to the SWE method and was therefore chosen as the method of choice for the analysis of real sludge samples. The PCBs under study (PCB 28, 52, 101, 118, 138, 153 and 180) when analysed using gas chromatography electron capture detector gave low detection limit in the range of 0.016 to 0.048 µg/mL. The concentration of PCBs in sludge samples extracted using SFCO2 were in the range of 31.2 to 82.0 µg/kg as compared to that using Soxhlet extraction with PCB levels from 20.2 to 60.1 µg/kg. The characterization of sludge samples from other aspects was also carried out. The sludge samples showed slightly acidic pH values ranging from 4.3 to 6.6. All samples were found to be chemically stable and the percentages of nutrient (nitrogen, phosphorus and potassium) were in the range of 0.059 to 0.98%, 0.05 to 0.15% and 0.12 to 0.16%, respectively. Heavy metal studies showed that metal content in municipal sewage sludge samples were below the United States Environmental Protection Agency limit. 2007-05 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/9825/1/AhmadZamaniHalimMFS2007.pdf Ab. Halim, Ahmad Zamani (2007) Analysis of polychlorinated biphenyls in sewage sludge using supercritical carbon dioxide and subcritical water extraction. Masters thesis, Universiti Teknologi Malaysia, Faculty of Science. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:1219
spellingShingle QD Chemistry
Ab. Halim, Ahmad Zamani
Analysis of polychlorinated biphenyls in sewage sludge using supercritical carbon dioxide and subcritical water extraction
title Analysis of polychlorinated biphenyls in sewage sludge using supercritical carbon dioxide and subcritical water extraction
title_full Analysis of polychlorinated biphenyls in sewage sludge using supercritical carbon dioxide and subcritical water extraction
title_fullStr Analysis of polychlorinated biphenyls in sewage sludge using supercritical carbon dioxide and subcritical water extraction
title_full_unstemmed Analysis of polychlorinated biphenyls in sewage sludge using supercritical carbon dioxide and subcritical water extraction
title_short Analysis of polychlorinated biphenyls in sewage sludge using supercritical carbon dioxide and subcritical water extraction
title_sort analysis of polychlorinated biphenyls in sewage sludge using supercritical carbon dioxide and subcritical water extraction
topic QD Chemistry
url http://eprints.utm.my/9825/
http://eprints.utm.my/9825/
http://eprints.utm.my/9825/1/AhmadZamaniHalimMFS2007.pdf