Transient stability analysis of power system with six-phase converted transmission line
Enhanced power transfer capability through a six-phase converted transmission system is becoming an area of growing interest in the power system industry. However, this conversion will have an impact on the system stability. In this paper, the transient stability of a 4-bus, 2 generators test system...
| Main Authors: | , |
|---|---|
| Format: | Conference or Workshop Item |
| Published: |
2006
|
| Subjects: | |
| Online Access: | http://eprints.utm.my/7640/ |
| _version_ | 1848891510800515072 |
|---|---|
| author | Mustafa, Mohd. Wazir Ahmad, Mohd. Redzuan |
| author_facet | Mustafa, Mohd. Wazir Ahmad, Mohd. Redzuan |
| author_sort | Mustafa, Mohd. Wazir |
| building | UTeM Institutional Repository |
| collection | Online Access |
| description | Enhanced power transfer capability through a six-phase converted transmission system is becoming an area of growing interest in the power system industry. However, this conversion will have an impact on the system stability. In this paper, the transient stability of a 4-bus, 2 generators test system is investigated in time domain considering conversion of threephase double-circuit to the six-phase single-circuit transmission system. The paper presents also comparisons between critical clearing times for both three and six-phase cases. All types of fault on the middle of transmission line are simulated using PSCAD/EMTDC. From the simulation results, it has been shown that the 4-bus, 2 generators test system with six-phase single-circuit transmission has a better stability limits compare to the three-phase double-circuit transmission. |
| first_indexed | 2025-11-15T20:59:07Z |
| format | Conference or Workshop Item |
| id | utm-7640 |
| institution | Universiti Teknologi Malaysia |
| institution_category | Local University |
| last_indexed | 2025-11-15T20:59:07Z |
| publishDate | 2006 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | utm-76402009-01-13T06:48:23Z http://eprints.utm.my/7640/ Transient stability analysis of power system with six-phase converted transmission line Mustafa, Mohd. Wazir Ahmad, Mohd. Redzuan TK Electrical engineering. Electronics Nuclear engineering Enhanced power transfer capability through a six-phase converted transmission system is becoming an area of growing interest in the power system industry. However, this conversion will have an impact on the system stability. In this paper, the transient stability of a 4-bus, 2 generators test system is investigated in time domain considering conversion of threephase double-circuit to the six-phase single-circuit transmission system. The paper presents also comparisons between critical clearing times for both three and six-phase cases. All types of fault on the middle of transmission line are simulated using PSCAD/EMTDC. From the simulation results, it has been shown that the 4-bus, 2 generators test system with six-phase single-circuit transmission has a better stability limits compare to the three-phase double-circuit transmission. 2006 Conference or Workshop Item PeerReviewed Mustafa, Mohd. Wazir and Ahmad, Mohd. Redzuan (2006) Transient stability analysis of power system with six-phase converted transmission line. In: First International Power and Energy Conference, (PECon 2006) Proceedings , 28-29 Nov. 2006 , Putrajaya, Malaysia. http://dx.doi.org/10.1109/PECON.2006.346659 |
| spellingShingle | TK Electrical engineering. Electronics Nuclear engineering Mustafa, Mohd. Wazir Ahmad, Mohd. Redzuan Transient stability analysis of power system with six-phase converted transmission line |
| title | Transient stability analysis of power system with six-phase converted transmission line |
| title_full | Transient stability analysis of power system with six-phase converted transmission line |
| title_fullStr | Transient stability analysis of power system with six-phase converted transmission line |
| title_full_unstemmed | Transient stability analysis of power system with six-phase converted transmission line |
| title_short | Transient stability analysis of power system with six-phase converted transmission line |
| title_sort | transient stability analysis of power system with six-phase converted transmission line |
| topic | TK Electrical engineering. Electronics Nuclear engineering |
| url | http://eprints.utm.my/7640/ http://eprints.utm.my/7640/ |