The use of mechanical interlock in dental prosthesis

Good long term outcomes in prosthetic dentistry depends on the stability of its abutment-implant construct. One of the abutment designs normally used is a cylindrical taper where interference fit is achieved on large contact pressure and frictional resistance at the interface. Other designs include...

Full description

Bibliographic Details
Main Authors: Abdul Kadir, Mohammed Rafiq, Osman, K., Zainuddin, A. I.
Format: Book Section
Published: Springer Berlin Heidelberg 2008
Subjects:
Online Access:http://eprints.utm.my/6954/
_version_ 1848891378489098240
author Abdul Kadir, Mohammed Rafiq
Osman, K.
Zainuddin, A. I.
author_facet Abdul Kadir, Mohammed Rafiq
Osman, K.
Zainuddin, A. I.
author_sort Abdul Kadir, Mohammed Rafiq
building UTeM Institutional Repository
collection Online Access
description Good long term outcomes in prosthetic dentistry depends on the stability of its abutment-implant construct. One of the abutment designs normally used is a cylindrical taper where interference fit is achieved on large contact pressure and frictional resistance at the interface. Other designs include the screw and a combination of screw and taper. The stability of the implant body relative to the bone is also crucial because inadequate fixation would prevent bone integration. This study analysed a concept design where the abutment is locked mechanically once inserted into the dental implant body. Non-linear finite element contact analysis was carried out on the new design, as well as on a design based on a simple taper for comparison. Three dimensional model of the mandible was reconstructed from CT dataset and a section of the mandible was chosen for analysis. Pressure was applied on the top surface of the abutment simulating the normal biting force. Results showed that the mechanical interlock design was 5 times more stable than the simple taper design. However, the threshold limit for osseointegration was not exceeded for both implants. Stresses exerted on the distal region of the abutment for the taper design was an order of magnitude higher than the one found on the mechanical interlock.
first_indexed 2025-11-15T20:57:01Z
format Book Section
id utm-6954
institution Universiti Teknologi Malaysia
institution_category Local University
last_indexed 2025-11-15T20:57:01Z
publishDate 2008
publisher Springer Berlin Heidelberg
recordtype eprints
repository_type Digital Repository
spelling utm-69542017-07-25T03:30:45Z http://eprints.utm.my/6954/ The use of mechanical interlock in dental prosthesis Abdul Kadir, Mohammed Rafiq Osman, K. Zainuddin, A. I. TJ Mechanical engineering and machinery Good long term outcomes in prosthetic dentistry depends on the stability of its abutment-implant construct. One of the abutment designs normally used is a cylindrical taper where interference fit is achieved on large contact pressure and frictional resistance at the interface. Other designs include the screw and a combination of screw and taper. The stability of the implant body relative to the bone is also crucial because inadequate fixation would prevent bone integration. This study analysed a concept design where the abutment is locked mechanically once inserted into the dental implant body. Non-linear finite element contact analysis was carried out on the new design, as well as on a design based on a simple taper for comparison. Three dimensional model of the mandible was reconstructed from CT dataset and a section of the mandible was chosen for analysis. Pressure was applied on the top surface of the abutment simulating the normal biting force. Results showed that the mechanical interlock design was 5 times more stable than the simple taper design. However, the threshold limit for osseointegration was not exceeded for both implants. Stresses exerted on the distal region of the abutment for the taper design was an order of magnitude higher than the one found on the mechanical interlock. Springer Berlin Heidelberg 2008 Book Section PeerReviewed Abdul Kadir, Mohammed Rafiq and Osman, K. and Zainuddin, A. I. (2008) The use of mechanical interlock in dental prosthesis. In: IFMBE Proceedings. Springer Berlin Heidelberg, pp. 457-460. ISBN 1680-0737 https://link.springer.com/chapter/10.1007%2F978-3-540-69139-6_116
spellingShingle TJ Mechanical engineering and machinery
Abdul Kadir, Mohammed Rafiq
Osman, K.
Zainuddin, A. I.
The use of mechanical interlock in dental prosthesis
title The use of mechanical interlock in dental prosthesis
title_full The use of mechanical interlock in dental prosthesis
title_fullStr The use of mechanical interlock in dental prosthesis
title_full_unstemmed The use of mechanical interlock in dental prosthesis
title_short The use of mechanical interlock in dental prosthesis
title_sort use of mechanical interlock in dental prosthesis
topic TJ Mechanical engineering and machinery
url http://eprints.utm.my/6954/
http://eprints.utm.my/6954/