Insulation coordination of quadruple circuit high voltage transmission lines using ATP-EMTP

A significant number of faults in overhead transmission lines are due to lightning strikes which cause back flashovers and hence single or double circuit outages. The continuity and quality of the power supply is therefore can be severely affected by the outages, especially in Malaysia where the iso...

Full description

Bibliographic Details
Main Author: Dugel, Siti Rugayah
Format: Thesis
Language:English
Published: 2007
Subjects:
Online Access:http://eprints.utm.my/5777/
http://eprints.utm.my/5777/1/SitiRugayahDugelMFKE2007.pdf
_version_ 1848891122141626368
author Dugel, Siti Rugayah
author_facet Dugel, Siti Rugayah
author_sort Dugel, Siti Rugayah
building UTeM Institutional Repository
collection Online Access
description A significant number of faults in overhead transmission lines are due to lightning strikes which cause back flashovers and hence single or double circuit outages. The continuity and quality of the power supply is therefore can be severely affected by the outages, especially in Malaysia where the isokeraunic level is rather high. The lightning performance of transmission lines is also influenced by the transmission line configuration itself. In Malaysia, the TNB's transmission lines consist of 500 kV or 275 kV double circuits, and 275/132 kV quadruple circuits. It is known that the lower portion of the 132 kV line apparently has the lowest lightning performance.
first_indexed 2025-11-15T20:52:56Z
format Thesis
id utm-5777
institution Universiti Teknologi Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T20:52:56Z
publishDate 2007
recordtype eprints
repository_type Digital Repository
spelling utm-57772018-08-26T04:42:57Z http://eprints.utm.my/5777/ Insulation coordination of quadruple circuit high voltage transmission lines using ATP-EMTP Dugel, Siti Rugayah TK Electrical engineering. Electronics Nuclear engineering A significant number of faults in overhead transmission lines are due to lightning strikes which cause back flashovers and hence single or double circuit outages. The continuity and quality of the power supply is therefore can be severely affected by the outages, especially in Malaysia where the isokeraunic level is rather high. The lightning performance of transmission lines is also influenced by the transmission line configuration itself. In Malaysia, the TNB's transmission lines consist of 500 kV or 275 kV double circuits, and 275/132 kV quadruple circuits. It is known that the lower portion of the 132 kV line apparently has the lowest lightning performance. 2007-05 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/5777/1/SitiRugayahDugelMFKE2007.pdf Dugel, Siti Rugayah (2007) Insulation coordination of quadruple circuit high voltage transmission lines using ATP-EMTP. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:62125
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Dugel, Siti Rugayah
Insulation coordination of quadruple circuit high voltage transmission lines using ATP-EMTP
title Insulation coordination of quadruple circuit high voltage transmission lines using ATP-EMTP
title_full Insulation coordination of quadruple circuit high voltage transmission lines using ATP-EMTP
title_fullStr Insulation coordination of quadruple circuit high voltage transmission lines using ATP-EMTP
title_full_unstemmed Insulation coordination of quadruple circuit high voltage transmission lines using ATP-EMTP
title_short Insulation coordination of quadruple circuit high voltage transmission lines using ATP-EMTP
title_sort insulation coordination of quadruple circuit high voltage transmission lines using atp-emtp
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.utm.my/5777/
http://eprints.utm.my/5777/
http://eprints.utm.my/5777/1/SitiRugayahDugelMFKE2007.pdf