Finite element modelling of primary hip stem stability: The effect of interference fit
The most commonly reported complications related to cementless hip stems are loosening and thigh pain; both of these have been attributed to high levels of relative micromotion at the bone–implant interface due to insufficient primary fixation. Primary fixation is believed by many to rely on achie...
| Main Authors: | Abdul-Kadir, Mohammed Rafiq, Ulrich, Hansen, Ralf, Klabunde, Duncan, Lucas, Andrew, Amis |
|---|---|
| Format: | Article |
| Published: |
Elsevier
2008
|
| Subjects: | |
| Online Access: | http://eprints.utm.my/5418/ |
Similar Items
Incorporation of interference fit and cyclic loading in simulation algorithm for better prediction of micromotion of femoral stems
by: Abdul-Kadir, Mohammed Rafiq, et al.
Published: (2007)
by: Abdul-Kadir, Mohammed Rafiq, et al.
Published: (2007)
The effect of physiological load configuration on interface micromotion in cementless femoral stems
by: Abdul Kadir, Mohammed Rafiq, et al.
Published: (2007)
by: Abdul Kadir, Mohammed Rafiq, et al.
Published: (2007)
Finite element modeling of a generic stemless hip implant design in comparison with conventional hip implants
by: Asgari, Seyed Alireza, et al.
Published: (2004)
by: Asgari, Seyed Alireza, et al.
Published: (2004)
Finite element method prediction of hip prosthesis in bone resorption environment
by: Shuib, Solehuddin
Published: (2012)
by: Shuib, Solehuddin
Published: (2012)
Finite element analysis of hip implant using additive manufacturing materials in different loading conditions
by: Noman, Abdulla All, et al.
Published: (2025)
by: Noman, Abdulla All, et al.
Published: (2025)
Contact slip prediction in HAp coated artificial hip implant using finite element analysis
by: NAGENTRAU, Muniandy, et al.
Published: (2019)
by: NAGENTRAU, Muniandy, et al.
Published: (2019)
Goodness-of-fit and detection problems in impulsive interference.
by: Brown, Christopher L.
Published: (2000)
by: Brown, Christopher L.
Published: (2000)
Study of factors affecting taper joint failures in modular hip implant using finite element modelling
by: Abdullah, Kassim
Published: (2001)
by: Abdullah, Kassim
Published: (2001)
Finite element study of metacarpophalangeal joint silicone implants
by: Abdul Kadir, Mohammed Rafiq, et al.
Published: (2008)
by: Abdul Kadir, Mohammed Rafiq, et al.
Published: (2008)
Stress analysis of femur and femoral stems for hip arthroplasty
by: Wong, King Jye
Published: (2006)
by: Wong, King Jye
Published: (2006)
Analysis of slope stability using finite element method
by: Mohd Yusri, Bin Suratman
Published: (2009)
by: Mohd Yusri, Bin Suratman
Published: (2009)
Finite Element Analysis of Elastomeric Push Fit Spigot and Socket Steel Pipe Joint
by: Abdul Aziz, Nuraini
Published: (2000)
by: Abdul Aziz, Nuraini
Published: (2000)
Finite element analysis of elastomeric push-fit spigot and socket steel pipe joint
by: Abdul Aziz, Nuraini, et al.
Published: (2001)
by: Abdul Aziz, Nuraini, et al.
Published: (2001)
Simulation of implant fitting in the hip bone using maya / Adi Dewiyana Abdul Hadi
by: Adi Dewiyana, Abdul Hadi
Published: (2003)
by: Adi Dewiyana, Abdul Hadi
Published: (2003)
Interface micromotion failure simulation of cementless hip prosthesis
by: Abdul Kadir, Mohammed Rafiq, et al.
Published: (2007)
by: Abdul Kadir, Mohammed Rafiq, et al.
Published: (2007)
Stability analysis on tower crane foundation using finite element method
by: Faizatul Shima,, et al.
Published: (2022)
by: Faizatul Shima,, et al.
Published: (2022)
Finite Element Modeling For Solving The Pulsatile Flow In A Fusiform Abdominal Aortic Aneurysm
by: Vijayajothi , Paramasivam, et al.
Published: (2010)
by: Vijayajothi , Paramasivam, et al.
Published: (2010)
“Our Lives are Lived in Freestyle”: Social and Dynamic Productions of Breaking and Hip Hop Culture
by: Marie, Lucas
Published: (2018)
by: Marie, Lucas
Published: (2018)
The biomechanics of various fixations for syndesmotic joint diasthesis: a finite element study
by: Che Ahmad, Aminudin, et al.
Published: (2014)
by: Che Ahmad, Aminudin, et al.
Published: (2014)
Influence of prosthesis stem tapers in cementless hip arthrosplasty / Muhamad Firdaus Selamat.
by: Selamat, Muhamad Firdaus
Published: (2009)
by: Selamat, Muhamad Firdaus
Published: (2009)
A study on geotechnical behavior of stabilized peat soil with finite element modeling
by: Sii, Hee Yew
Published: (2012)
by: Sii, Hee Yew
Published: (2012)
Performance of dual lips elastomeric seal for spigot-socket push fit joint using finite element method
by: Abdul Aziz, Nuraini, et al.
Published: (2009)
by: Abdul Aziz, Nuraini, et al.
Published: (2009)
Can we safely deform a plate to fit every bone? population-based fit assessment and finite element deformation of a distal tibial plate
by: Harith, Hazreen Haizi, et al.
Published: (2016)
by: Harith, Hazreen Haizi, et al.
Published: (2016)
Crack Music: Representations of the Drugs Trade in New York Hip-Hop
by: Duncan, Andrew
Published: (2024)
by: Duncan, Andrew
Published: (2024)
Sufficient condition of stability of finite element method for symmetric T-hyperbolic systems with constant coefficients
by: Djuraevich, Aloev Raxmatillo, et al.
Published: (2014)
by: Djuraevich, Aloev Raxmatillo, et al.
Published: (2014)
Finite Element Computation for Solving Pulsatile Blood Flow: Relevance in Assessing the Flow Dynamics in Abdominal Aortic Aneurysms
by: Vijayajothi , Paramasivam, et al.
Published: (2010)
by: Vijayajothi , Paramasivam, et al.
Published: (2010)
Design process of cementless femoral stem using a nonlinear three dimensional finite element analysis
by: Baharuddin, Mohd Yusof, et al.
Published: (2014)
by: Baharuddin, Mohd Yusof, et al.
Published: (2014)
Finite element analysis of proximal femur using Charnley Elite type stem / Muhamad Zaidi Salim
by: Salim, Muhamad Zaidi
Published: (2009)
by: Salim, Muhamad Zaidi
Published: (2009)
Finite element analysis of proximal femur using Charnley elite type stem / Muhamad Zaidi Salem.
by: Salem, Muhamad Zaidi
Published: (2009)
by: Salem, Muhamad Zaidi
Published: (2009)
Hip precautions after hip operation (HippityHop): a
before and after study evaluating hip precautions following total hip replacement
by: Lightfoot, Courtney Jane
Published: (2019)
by: Lightfoot, Courtney Jane
Published: (2019)
Hip fixation
by: Sulong, Ahmad Fadzli
Published: (2014)
by: Sulong, Ahmad Fadzli
Published: (2014)
A review of the efficacy of intraarticular hip injection for patients with hip osteoarthritis: to inject or not to inject in hip osteoarthritis?
by: Rampal, Sanjiv, et al.
Published: (2022)
by: Rampal, Sanjiv, et al.
Published: (2022)
Hip precautions after hip operation (HippityHop): protocol for a before and after study evaluating hip precautions following total hip replacement
by: Lightfoot, C.J., et al.
Published: (2018)
by: Lightfoot, C.J., et al.
Published: (2018)
Predictors of early stem loosening after total hip arthroplasty: a case-control study.
by: Melloh, Markus, et al.
Published: (2011)
by: Melloh, Markus, et al.
Published: (2011)
Effects of prosthesis stem length on stress distribution in cementless hip arthroplasty / Emmi Farisa Jaafar.
by: Jaafar, Emmi Farisa
Published: (2009)
by: Jaafar, Emmi Farisa
Published: (2009)
ANSYS finite element design of an energy saving magneto-rheological damper with improved dispersion stability
by: Rashid, Muhammad Mahbubur, et al.
Published: (2015)
by: Rashid, Muhammad Mahbubur, et al.
Published: (2015)
Evaluating perovskite solar panels for thermal stability and inclination performance through finite element modelling
by: Wang, Ranfu, et al.
Published: (2024)
by: Wang, Ranfu, et al.
Published: (2024)
The design improvement of hip implant for total hip replacement (THR)
by: Solehuddin Shuib,, et al.
Published: (2008)
by: Solehuddin Shuib,, et al.
Published: (2008)
Finite element model updating
by: Syed Muhammad, Kashif
Published: (2011)
by: Syed Muhammad, Kashif
Published: (2011)
Mixed Velocity-Pressure (v-p) Finite Element Method in Assessing the Hemodynamic Wall Shear Stresses in a Fusiform Abdominal Aortic Aneurysm
by: Vijayajothi , Paramasivam, et al.
Published: (1995)
by: Vijayajothi , Paramasivam, et al.
Published: (1995)
Similar Items
-
Incorporation of interference fit and cyclic loading in simulation algorithm for better prediction of micromotion of femoral stems
by: Abdul-Kadir, Mohammed Rafiq, et al.
Published: (2007) -
The effect of physiological load configuration on interface micromotion in cementless femoral stems
by: Abdul Kadir, Mohammed Rafiq, et al.
Published: (2007) -
Finite element modeling of a generic stemless hip implant design in comparison with conventional hip implants
by: Asgari, Seyed Alireza, et al.
Published: (2004) -
Finite element method prediction of hip prosthesis in bone resorption environment
by: Shuib, Solehuddin
Published: (2012) -
Finite element analysis of hip implant using additive manufacturing materials in different loading conditions
by: Noman, Abdulla All, et al.
Published: (2025)