Alternative design of foundations subjected to uplift for transmission line tower

Transmission line is a medium to carry power loads from one station to another station, therefore; it is one of the most important projects in power business. An efficient design of foundations for transmission line towers has always been a challenge for the engineers due to the variety and cyclic n...

Full description

Bibliographic Details
Main Author: Narayanan Nair, Purushothaman Nair
Format: Thesis
Language:English
Published: 2006
Subjects:
Online Access:http://eprints.utm.my/4903/
http://eprints.utm.my/4903/1/PurushothamanNairNarayananMFKA2006.pdf
_version_ 1848890917203738624
author Narayanan Nair, Purushothaman Nair
author_facet Narayanan Nair, Purushothaman Nair
author_sort Narayanan Nair, Purushothaman Nair
building UTeM Institutional Repository
collection Online Access
description Transmission line is a medium to carry power loads from one station to another station, therefore; it is one of the most important projects in power business. An efficient design of foundations for transmission line towers has always been a challenge for the engineers due to the variety and cyclic nature of the loads. Foundations especially for the four legged type are subjected to combinations of all types of loads i.e: compression, uplift, torsion and shear. The current practice of non-shored excavation for the construction of the transmission tower foundation does not comply with the safety regulation. Thus, the main objective of this study is to evaluate current design practices for standard undercut foundations (1 Undercut and 2 Undercut) for transmission line projects undertaken by TNB. Furthermore, alternative foundation design and their performance will be in term of safety and concrete volume. The study is based on an ongoing project i.e a 275Kv Transmission Line from Melaka to Kelemak. In this research, drilled shaft was identified as alternative foundation for transmission line towers. Even-though the construction cost is higher than the conventional method, but drilled shaft can eliminate or reduce unsafe act and unsafe condition thus will reduce the incidents or near misses. Furthermore drilled shaft also comply with the requirement of FMA and OSHA which was identified as a main objective of this study.
first_indexed 2025-11-15T20:49:41Z
format Thesis
id utm-4903
institution Universiti Teknologi Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T20:49:41Z
publishDate 2006
recordtype eprints
repository_type Digital Repository
spelling utm-49032018-02-28T06:49:20Z http://eprints.utm.my/4903/ Alternative design of foundations subjected to uplift for transmission line tower Narayanan Nair, Purushothaman Nair TA Engineering (General). Civil engineering (General) Transmission line is a medium to carry power loads from one station to another station, therefore; it is one of the most important projects in power business. An efficient design of foundations for transmission line towers has always been a challenge for the engineers due to the variety and cyclic nature of the loads. Foundations especially for the four legged type are subjected to combinations of all types of loads i.e: compression, uplift, torsion and shear. The current practice of non-shored excavation for the construction of the transmission tower foundation does not comply with the safety regulation. Thus, the main objective of this study is to evaluate current design practices for standard undercut foundations (1 Undercut and 2 Undercut) for transmission line projects undertaken by TNB. Furthermore, alternative foundation design and their performance will be in term of safety and concrete volume. The study is based on an ongoing project i.e a 275Kv Transmission Line from Melaka to Kelemak. In this research, drilled shaft was identified as alternative foundation for transmission line towers. Even-though the construction cost is higher than the conventional method, but drilled shaft can eliminate or reduce unsafe act and unsafe condition thus will reduce the incidents or near misses. Furthermore drilled shaft also comply with the requirement of FMA and OSHA which was identified as a main objective of this study. 2006-11 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/4903/1/PurushothamanNairNarayananMFKA2006.pdf Narayanan Nair, Purushothaman Nair (2006) Alternative design of foundations subjected to uplift for transmission line tower. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.
spellingShingle TA Engineering (General). Civil engineering (General)
Narayanan Nair, Purushothaman Nair
Alternative design of foundations subjected to uplift for transmission line tower
title Alternative design of foundations subjected to uplift for transmission line tower
title_full Alternative design of foundations subjected to uplift for transmission line tower
title_fullStr Alternative design of foundations subjected to uplift for transmission line tower
title_full_unstemmed Alternative design of foundations subjected to uplift for transmission line tower
title_short Alternative design of foundations subjected to uplift for transmission line tower
title_sort alternative design of foundations subjected to uplift for transmission line tower
topic TA Engineering (General). Civil engineering (General)
url http://eprints.utm.my/4903/
http://eprints.utm.my/4903/1/PurushothamanNairNarayananMFKA2006.pdf