Evaluation of design criteria for inflow & infiltration of medium scale sewerage catchment system

Infiltration rate has long been important aspect considered in the design of sewerage systems. The study is about assessment of the extent of extraneous water that infiltrates into sewer pipes in the sewerage system and the appropriateness of the design criteria, under local conditions. The study is...

Full description

Bibliographic Details
Main Authors: Abd. Rahman, Norhan, Othman, Mohamad Abd. Rashid, Othman, Mohamad @ Abd. Rashid, Alias, Noraliani, Mohd. Salleh, Siti Salhawati, Othman, Norasman, Mohamad, Ahmad Faisal, Ansari, Kamran
Format: Monograph
Language:English
Published: Faculty of Civil Engineering 2006
Subjects:
Online Access:http://eprints.utm.my/3848/
http://eprints.utm.my/3848/1/74281.pdf
_version_ 1848890659146039296
author Abd. Rahman, Norhan
Othman, Mohamad Abd. Rashid
Othman, Mohamad @ Abd. Rashid
Alias, Noraliani
Mohd. Salleh, Siti Salhawati
Othman, Norasman
Mohamad, Ahmad Faisal
Ansari, Kamran
author_facet Abd. Rahman, Norhan
Othman, Mohamad Abd. Rashid
Othman, Mohamad @ Abd. Rashid
Alias, Noraliani
Mohd. Salleh, Siti Salhawati
Othman, Norasman
Mohamad, Ahmad Faisal
Ansari, Kamran
author_sort Abd. Rahman, Norhan
building UTeM Institutional Repository
collection Online Access
description Infiltration rate has long been important aspect considered in the design of sewerage systems. The study is about assessment of the extent of extraneous water that infiltrates into sewer pipes in the sewerage system and the appropriateness of the design criteria, under local conditions. The study is divided into two parts, flow characteristics measurement and infiltration measurement. Flow characteristics measurement includes collecting data using flowmeter at a pre-determined manhole and analyzing the data to find hourly flow characteristics, flow per capita contribution and the peak flow factor. Infiltration measurement is carried out at an abandoned sewer line (MH74-MH74a) in Taman Sri Pulai for a year, at active sewer line in Taman Universiti and at Hydraulic & Hydrology Laboratory, Faculty of Civil Engineering, UTM. The data collected is converted into graph form before analysis. Rainfall data has been collected to identify its influence on the infiltration rate. The results from both flow characteristics measurement and infiltration measurement are compared with design infiltration rate as mentioned in MS1228:1991, which is 50 liter/day/km/mm-dia as well as with previous studies on inflow and infiltration carried out in Taman Sri Pulai and Taman Universiti. The results showed that the flow per capita contribution and the peak flow factor in Taman Sri Pulai and Taman Universiti are lower than recommended in MS1228:1991 and that wet periods contribute more infiltration compared to dry periods. Infiltration rate will increase with the increase in rainfall volume.
first_indexed 2025-11-15T20:45:35Z
format Monograph
id utm-3848
institution Universiti Teknologi Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T20:45:35Z
publishDate 2006
publisher Faculty of Civil Engineering
recordtype eprints
repository_type Digital Repository
spelling utm-38482017-08-06T08:26:53Z http://eprints.utm.my/3848/ Evaluation of design criteria for inflow & infiltration of medium scale sewerage catchment system Abd. Rahman, Norhan Othman, Mohamad Abd. Rashid Othman, Mohamad @ Abd. Rashid Alias, Noraliani Mohd. Salleh, Siti Salhawati Othman, Norasman Mohamad, Ahmad Faisal Ansari, Kamran TD Environmental technology. Sanitary engineering Infiltration rate has long been important aspect considered in the design of sewerage systems. The study is about assessment of the extent of extraneous water that infiltrates into sewer pipes in the sewerage system and the appropriateness of the design criteria, under local conditions. The study is divided into two parts, flow characteristics measurement and infiltration measurement. Flow characteristics measurement includes collecting data using flowmeter at a pre-determined manhole and analyzing the data to find hourly flow characteristics, flow per capita contribution and the peak flow factor. Infiltration measurement is carried out at an abandoned sewer line (MH74-MH74a) in Taman Sri Pulai for a year, at active sewer line in Taman Universiti and at Hydraulic & Hydrology Laboratory, Faculty of Civil Engineering, UTM. The data collected is converted into graph form before analysis. Rainfall data has been collected to identify its influence on the infiltration rate. The results from both flow characteristics measurement and infiltration measurement are compared with design infiltration rate as mentioned in MS1228:1991, which is 50 liter/day/km/mm-dia as well as with previous studies on inflow and infiltration carried out in Taman Sri Pulai and Taman Universiti. The results showed that the flow per capita contribution and the peak flow factor in Taman Sri Pulai and Taman Universiti are lower than recommended in MS1228:1991 and that wet periods contribute more infiltration compared to dry periods. Infiltration rate will increase with the increase in rainfall volume. Faculty of Civil Engineering 2006-12-31 Monograph NonPeerReviewed application/pdf en http://eprints.utm.my/3848/1/74281.pdf Abd. Rahman, Norhan and Othman, Mohamad Abd. Rashid and Othman, Mohamad @ Abd. Rashid and Alias, Noraliani and Mohd. Salleh, Siti Salhawati and Othman, Norasman and Mohamad, Ahmad Faisal and Ansari, Kamran (2006) Evaluation of design criteria for inflow & infiltration of medium scale sewerage catchment system. Project Report. Faculty of Civil Engineering, Skudai, Johor. (Unpublished) https://www.researchgate.net/publication/240615389_EVALUATION_OF_DESIGN_CRITERIA_FOR_INFLOW_INFILTRATION_OF_MEDIUM_SCALE_SEWERAGE_CATCHMENT_SYSTEM_PENILAIAN_KRITERIA_REKABENTUK_BAGI_ALIRAN_MASUK_PENYUSUPAN_SISTEM_PEMBENTUNGAN_BERSKALA_SEDERHANA
spellingShingle TD Environmental technology. Sanitary engineering
Abd. Rahman, Norhan
Othman, Mohamad Abd. Rashid
Othman, Mohamad @ Abd. Rashid
Alias, Noraliani
Mohd. Salleh, Siti Salhawati
Othman, Norasman
Mohamad, Ahmad Faisal
Ansari, Kamran
Evaluation of design criteria for inflow & infiltration of medium scale sewerage catchment system
title Evaluation of design criteria for inflow & infiltration of medium scale sewerage catchment system
title_full Evaluation of design criteria for inflow & infiltration of medium scale sewerage catchment system
title_fullStr Evaluation of design criteria for inflow & infiltration of medium scale sewerage catchment system
title_full_unstemmed Evaluation of design criteria for inflow & infiltration of medium scale sewerage catchment system
title_short Evaluation of design criteria for inflow & infiltration of medium scale sewerage catchment system
title_sort evaluation of design criteria for inflow & infiltration of medium scale sewerage catchment system
topic TD Environmental technology. Sanitary engineering
url http://eprints.utm.my/3848/
http://eprints.utm.my/3848/
http://eprints.utm.my/3848/1/74281.pdf