Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC
In Malaysia, the demand for electric power is increasing day by day due to more consumption of power in the industrial sector. Recently, the high voltage DC transmission lines are under construction near the coastal environments for transmitting the power to the all states of Malaysia. Therefore, th...
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
2000
|
| Subjects: | |
| Online Access: | http://eprints.utm.my/2041/ http://eprints.utm.my/2041/1/Salam2000__EffectOfEquivalentSaltDeposit.pdf |
| _version_ | 1848890272344178688 |
|---|---|
| author | Salam, M. A. Ahmad, H. Saadom, Z. Budin, R. Tamsir, T. Buntat, Z. Piah, M. A. M. |
| author_facet | Salam, M. A. Ahmad, H. Saadom, Z. Budin, R. Tamsir, T. Buntat, Z. Piah, M. A. M. |
| author_sort | Salam, M. A. |
| building | UTeM Institutional Repository |
| collection | Online Access |
| description | In Malaysia, the demand for electric power is increasing day by day due to more consumption of power in the industrial sector. Recently, the high voltage DC transmission lines are under construction near the coastal environments for transmitting the power to the all states of Malaysia. Therefore, there is a concern about the reliability of these systems especially under adverse environmental conditions due to sea salt spray contamination. This reliability of this contaminated insulator can be improved through its performance studies. For this performance study, an analytical expression between flashover voltage and ESDD of the contaminated insulator has been proposed using Dimensional Analysis technique. The results obtained from the analytical expression are compared with the experimental results and in close agreement are found |
| first_indexed | 2025-11-15T20:39:26Z |
| format | Article |
| id | utm-2041 |
| institution | Universiti Teknologi Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T20:39:26Z |
| publishDate | 2000 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | utm-20412010-06-01T03:00:27Z http://eprints.utm.my/2041/ Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC Salam, M. A. Ahmad, H. Saadom, Z. Budin, R. Tamsir, T. Buntat, Z. Piah, M. A. M. TK Electrical engineering. Electronics Nuclear engineering In Malaysia, the demand for electric power is increasing day by day due to more consumption of power in the industrial sector. Recently, the high voltage DC transmission lines are under construction near the coastal environments for transmitting the power to the all states of Malaysia. Therefore, there is a concern about the reliability of these systems especially under adverse environmental conditions due to sea salt spray contamination. This reliability of this contaminated insulator can be improved through its performance studies. For this performance study, an analytical expression between flashover voltage and ESDD of the contaminated insulator has been proposed using Dimensional Analysis technique. The results obtained from the analytical expression are compared with the experimental results and in close agreement are found 2000-06-21 Article PeerReviewed application/pdf en http://eprints.utm.my/2041/1/Salam2000__EffectOfEquivalentSaltDeposit.pdf Salam, M. A. and Ahmad, H. and Saadom, Z. and Budin, R. and Tamsir, T. and Buntat, Z. and Piah, M. A. M. (2000) Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC. Properties and Applications of Dielectric Materials, 2000. Proceedings of the 6th International Conference on , 2 (2 vol. xxv+1075 ). pp. 821-824. |
| spellingShingle | TK Electrical engineering. Electronics Nuclear engineering Salam, M. A. Ahmad, H. Saadom, Z. Budin, R. Tamsir, T. Buntat, Z. Piah, M. A. M. Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC |
| title | Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC
|
| title_full | Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC
|
| title_fullStr | Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC
|
| title_full_unstemmed | Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC
|
| title_short | Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC
|
| title_sort | effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by hvdc |
| topic | TK Electrical engineering. Electronics Nuclear engineering |
| url | http://eprints.utm.my/2041/ http://eprints.utm.my/2041/1/Salam2000__EffectOfEquivalentSaltDeposit.pdf |