Window Width Estimation And The Application Of The Windowed Wigner-Ville Distribution In The Analysis Of Heart Sounds And Murmurs
This paper looks at the analysis of heart sounds and murmur using time-frequency signal analysis. The techniques used are the Wigner-Ville distribution (WVD) and windowed Wigner-Ville distribution (WWVD) that belonged to the bilinear class of time-frequency distribution. These techniques developed t...
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
2000
|
| Subjects: | |
| Online Access: | http://eprints.utm.my/1991/ http://eprints.utm.my/1991/1/AZuri2000_WindowWidthEstimationandtheApplication.pdf |
| _version_ | 1848890261913993216 |
|---|---|
| author | Sha'ameri, Ahmad Zuri Salleh, Sh-Hussain |
| author_facet | Sha'ameri, Ahmad Zuri Salleh, Sh-Hussain |
| author_sort | Sha'ameri, Ahmad Zuri |
| building | UTeM Institutional Repository |
| collection | Online Access |
| description | This paper looks at the analysis of heart sounds and murmur using time-frequency signal analysis. The techniques used are the Wigner-Ville distribution (WVD) and windowed Wigner-Ville distribution (WWVD) that belonged to the bilinear class of time-frequency distribution. These techniques developed to provide high-resolution time-frequency representation for time-varying signals. Due the nonlinear operation involved, interference terms are introduced in the time-frequency representation. The signals of interest are modeled as multicomponent signals and the characteristics of the signal in time-lag plane are observed. From the time-lag plane, the interference components are identified, and the appropriate window width is selected in the WWVD to remove the interference. Analysis results show that WWVD produces more accurate time-frequency representation compared to the WVD and the signal-to-interference is used to quantify the improvement |
| first_indexed | 2025-11-15T20:39:16Z |
| format | Article |
| id | utm-1991 |
| institution | Universiti Teknologi Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T20:39:16Z |
| publishDate | 2000 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | utm-19912010-06-01T03:00:08Z http://eprints.utm.my/1991/ Window Width Estimation And The Application Of The Windowed Wigner-Ville Distribution In The Analysis Of Heart Sounds And Murmurs Sha'ameri, Ahmad Zuri Salleh, Sh-Hussain TK Electrical engineering. Electronics Nuclear engineering This paper looks at the analysis of heart sounds and murmur using time-frequency signal analysis. The techniques used are the Wigner-Ville distribution (WVD) and windowed Wigner-Ville distribution (WWVD) that belonged to the bilinear class of time-frequency distribution. These techniques developed to provide high-resolution time-frequency representation for time-varying signals. Due the nonlinear operation involved, interference terms are introduced in the time-frequency representation. The signals of interest are modeled as multicomponent signals and the characteristics of the signal in time-lag plane are observed. From the time-lag plane, the interference components are identified, and the appropriate window width is selected in the WWVD to remove the interference. Analysis results show that WWVD produces more accurate time-frequency representation compared to the WVD and the signal-to-interference is used to quantify the improvement 2000-09-24 Article PeerReviewed application/pdf en http://eprints.utm.my/1991/1/AZuri2000_WindowWidthEstimationandtheApplication.pdf Sha'ameri, Ahmad Zuri and Salleh, Sh-Hussain (2000) Window Width Estimation And The Application Of The Windowed Wigner-Ville Distribution In The Analysis Of Heart Sounds And Murmurs. TENCON 2000. Proceedings , 2 . pp. 114-119. |
| spellingShingle | TK Electrical engineering. Electronics Nuclear engineering Sha'ameri, Ahmad Zuri Salleh, Sh-Hussain Window Width Estimation And The Application Of The Windowed Wigner-Ville Distribution In The Analysis Of Heart Sounds And Murmurs |
| title | Window Width Estimation And The Application Of The Windowed Wigner-Ville Distribution In The Analysis Of Heart Sounds And Murmurs |
| title_full | Window Width Estimation And The Application Of The Windowed Wigner-Ville Distribution In The Analysis Of Heart Sounds And Murmurs |
| title_fullStr | Window Width Estimation And The Application Of The Windowed Wigner-Ville Distribution In The Analysis Of Heart Sounds And Murmurs |
| title_full_unstemmed | Window Width Estimation And The Application Of The Windowed Wigner-Ville Distribution In The Analysis Of Heart Sounds And Murmurs |
| title_short | Window Width Estimation And The Application Of The Windowed Wigner-Ville Distribution In The Analysis Of Heart Sounds And Murmurs |
| title_sort | window width estimation and the application of the windowed wigner-ville distribution in the analysis of heart sounds and murmurs |
| topic | TK Electrical engineering. Electronics Nuclear engineering |
| url | http://eprints.utm.my/1991/ http://eprints.utm.my/1991/1/AZuri2000_WindowWidthEstimationandtheApplication.pdf |