Regression technique for prediction of salt contamination severity on high voltage insulators
On the east-coast of the Malaysia Peninsular, high voltage insulators of power plants and factories suffer from rapid salt contamination accumulation because of heavy wind coming from the South China Sea. One attempt has been made at one of these plants which is located about 500 meters from the sea...
| Main Authors: | Ahmad, Ahmad S., Ahmad, Hussein, Salam, Md. Abdus, Saad, Ahmad |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
2000
|
| Subjects: | |
| Online Access: | http://eprints.utm.my/1963/ http://eprints.utm.my/1963/1/HusseinAhmad2000_RegressionTechniqueForPredictionOf.pdf |
Similar Items
Prediction of salt contamination on high voltage insulators in rainy season using regression technique
by: S. Ahmad, Ahmad, et al.
Published: (2000)
by: S. Ahmad, Ahmad, et al.
Published: (2000)
Sea Salts Contamination Pattern on High Voltage Insulators In
Littoral Region of Peninsular Malaysia
by: Ahmad, Ahmad S., et al.
Published: (1999)
by: Ahmad, Ahmad S., et al.
Published: (1999)
Study Of Creepage Distance Of The Contaminated Insulator In Correlation With Salt Deposit Density
by: Salam, Md. Abdus, et al.
Published: (2000)
by: Salam, Md. Abdus, et al.
Published: (2000)
Prediction of flashover voltage of contaminated insulator using artificial neural networks
by: Alawi, Saleh Al, et al.
Published: (2006)
by: Alawi, Saleh Al, et al.
Published: (2006)
Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC
by: Salam, M. A., et al.
Published: (2000)
by: Salam, M. A., et al.
Published: (2000)
Modeling of various meteorological effects on contamination level for suspension type of high voltage insulators using ANN
by: Ahmad, Ahmad S., et al.
Published: (2002)
by: Ahmad, Ahmad S., et al.
Published: (2002)
Flashover phenomena of polluted insulators energized by AC voltage
by: Salam, Md. Abdus, et al.
Published: (1999)
by: Salam, Md. Abdus, et al.
Published: (1999)
Development the relationship between ESDD and the distance from the source of contaminants for the insulator
by: Salam, Md. Abdus, et al.
Published: (2000)
by: Salam, Md. Abdus, et al.
Published: (2000)
Development of mathematical relation between ESDD and wind velocity for a contaminated insulator in Malaysia
by: Abdus Salam, M., et al.
Published: (2000)
by: Abdus Salam, M., et al.
Published: (2000)
Flashover characteristics of bentonite contaminated insulation surfaces under high voltage conditions
by: Rusli, Halimatusaadiah
Published: (2014)
by: Rusli, Halimatusaadiah
Published: (2014)
Nanoparticles application in high voltage insulation systems
by: Kadim, Emran Jawad, et al.
Published: (2021)
by: Kadim, Emran Jawad, et al.
Published: (2021)
Harmonic components of leakage current as a diagnostic tool to study the aging of insulators
by: Ahmad, Hussein, et al.
Published: (2008)
by: Ahmad, Hussein, et al.
Published: (2008)
High Voltage Power Transformer Paper Insulation Assessment Techniques
by: Abu Bakar, Norazhar, et al.
Published: (2013)
by: Abu Bakar, Norazhar, et al.
Published: (2013)
Development of mathematical relation between ESDD and wind velocity for a contaminated insulator in Malaysia
by: Abdul Salam, M, et al.
Published: (2000)
by: Abdul Salam, M, et al.
Published: (2000)
Dielectric Properties Of Kenaf-Based Kraft Paper For High Voltage Insulation
by: Nor Azli, Muhammad Aid'zuddin
Published: (2018)
by: Nor Azli, Muhammad Aid'zuddin
Published: (2018)
Insulation coordination of quadruple circuit high voltage transmission lines using ATP-EMTP
by: Dugel, Siti Rugayah
Published: (2007)
by: Dugel, Siti Rugayah
Published: (2007)
Identification of insulator leakage current harmonic content
by: Ahmad, Hussein
Published: (2009)
by: Ahmad, Hussein
Published: (2009)
Sediment load prediction for rivers in Malaysia using evolutionary polynomial regression technique
by: Nadiatul Adilah, Ahmad Abdul Ghani, et al.
Published: (2018)
by: Nadiatul Adilah, Ahmad Abdul Ghani, et al.
Published: (2018)
Modeling leakage current and electric field behavior of wet contaminated insulators
by: Piah, M. A. M., et al.
Published: (2004)
by: Piah, M. A. M., et al.
Published: (2004)
Dynamic modelling of pollution flashover on high voltage outdoor insulators
by: Ali Salem, Ali Ahmed
Published: (2020)
by: Ali Salem, Ali Ahmed
Published: (2020)
Dielectric and electrical characteristics of palm oil-based nanofluid as high voltage insulation material / Mohamad Zul Hilmey Makmud
by: Mohamad Zul Hilmey , Makmud
Published: (2019)
by: Mohamad Zul Hilmey , Makmud
Published: (2019)
New design of high voltage surge arresters
by: Darus, Ahmad
Published: (2004)
by: Darus, Ahmad
Published: (2004)
Dielectric Strength And Electrical Surface Tracking Characteristics Of Sir Epdm Containing Alumina And Titanium Nano-Fillers For High Voltage Insulators
by: Muhamad Raslani, Muhamad Fairus Adzha
Published: (2016)
by: Muhamad Raslani, Muhamad Fairus Adzha
Published: (2016)
Odd and total harmonic insulator distortion of leakage current as a tool to estimate contamination level
by: Salem, Ali Ahmed, et al.
Published: (2020)
by: Salem, Ali Ahmed, et al.
Published: (2020)
Surface arcing of insulators due to bentonite contamination
by: Rusli, Halimatusaadiah, et al.
Published: (2015)
by: Rusli, Halimatusaadiah, et al.
Published: (2015)
Polymer insulator coated by room temperature vulcanization for strengthening voltage withstand capabilities
by: Jamaludin, Farah Adilah
Published: (2020)
by: Jamaludin, Farah Adilah
Published: (2020)
Determination of space charge characteristics on contaminated XLPE insulator
by: Mohd Razib, Siti Nabilah
Published: (2019)
by: Mohd Razib, Siti Nabilah
Published: (2019)
Evaluation of salt water intrusion in the Kuantan Estuary with the application of a 1-D analytical salt intrusion model integrating the predictive equations for dispersion and Van der Burgh’s coefficients
by: Gisen, J. I. A., et al.
Published: (2017)
by: Gisen, J. I. A., et al.
Published: (2017)
Revised Predictive Equations for Salt Intrusion Modelling in Estuaries
by: Gisen, J. I. A., et al.
Published: (2015)
by: Gisen, J. I. A., et al.
Published: (2015)
Switching characteristic and analysis of insulated-gate bipolar transistor (IGBT)
by: Bakhtiar, Ahmad
Published: (2009)
by: Bakhtiar, Ahmad
Published: (2009)
Study of Insulator to Withstand Switching Surges in Conversion Three to Six-Phase Transmission Line: Computer Simulation Analysis
by: Jambak, Muhammad Irfan, et al.
Published: (2006)
by: Jambak, Muhammad Irfan, et al.
Published: (2006)
On the voltage and electric field distribution along polymer insulator
by: Izadi, Mahdi, et al.
Published: (2014)
by: Izadi, Mahdi, et al.
Published: (2014)
Flat Price Prediction using Linear and Random Forest Regression based on Machine Learning Techniques
by: Jui, Julakha Jahan, et al.
Published: (2020)
by: Jui, Julakha Jahan, et al.
Published: (2020)
Silicon carbide (SiC) insulated gate bipolar transistors (IGBTs) for high voltage applications
by: Almpanis, Ioannis
Published: (2024)
by: Almpanis, Ioannis
Published: (2024)
Electrical Treeing Properties Of Silicone Rubber/Organo Montmorillonite Nanocomposites As An Insulator For High Voltage Applications
by: Abd Jamil, Abdul Azim
Published: (2015)
by: Abd Jamil, Abdul Azim
Published: (2015)
Properties of Linear Low Density Polyethylene Silicone Rubber Nanocomposites For High Voltage Insulation Application
by: Ismail, Nurul Hidayah Ismail_
Published: (2016)
by: Ismail, Nurul Hidayah Ismail_
Published: (2016)
Influence of air humidity and contamination on electrical field of polymer insulator
by: Abd Rahman, Muhammad Syahmi, et al.
Published: (2014)
by: Abd Rahman, Muhammad Syahmi, et al.
Published: (2014)
Prediction Of PM10 Using Multiple Linear Regression And Boosted Regression Trees
by: Hamid, Nur Haziqah Mohd
Published: (2017)
by: Hamid, Nur Haziqah Mohd
Published: (2017)
Voltage Swells Improvement in Low Voltage Network Using Dynamic Voltage Restorer
by: Omar, Rosli, et al.
Published: (2011)
by: Omar, Rosli, et al.
Published: (2011)
Effect of broken skirts on voltage distribution along insulator strings
by: Othman, Nordiana Azlin, et al.
Published: (2016)
by: Othman, Nordiana Azlin, et al.
Published: (2016)
Similar Items
-
Prediction of salt contamination on high voltage insulators in rainy season using regression technique
by: S. Ahmad, Ahmad, et al.
Published: (2000) -
Sea Salts Contamination Pattern on High Voltage Insulators In
Littoral Region of Peninsular Malaysia
by: Ahmad, Ahmad S., et al.
Published: (1999) -
Study Of Creepage Distance Of The Contaminated Insulator In Correlation With Salt Deposit Density
by: Salam, Md. Abdus, et al.
Published: (2000) -
Prediction of flashover voltage of contaminated insulator using artificial neural networks
by: Alawi, Saleh Al, et al.
Published: (2006) -
Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC
by: Salam, M. A., et al.
Published: (2000)