An account of a modified lightning protection system for power stations

Power stations may face huge losses and damage when struck by lightning. Much effort has been carried out to find an alternative to the conventional lightning air terminal for direct protection to power stations. One of the alternative is to modify the tip configuration of conventional air terminals...

Full description

Bibliographic Details
Main Authors: Ahmad, Hussein, Ong, L. M.
Format: Article
Language:English
Published: 2005
Subjects:
Online Access:http://eprints.utm.my/1644/
http://eprints.utm.my/1644/1/hussein05_Account_of_modified_lightning.pdf
_version_ 1848890178550104064
author Ahmad, Hussein
Ong, L. M.
author_facet Ahmad, Hussein
Ong, L. M.
author_sort Ahmad, Hussein
building UTeM Institutional Repository
collection Online Access
description Power stations may face huge losses and damage when struck by lightning. Much effort has been carried out to find an alternative to the conventional lightning air terminal for direct protection to power stations. One of the alternative is to modify the tip configuration of conventional air terminals to enable it to be better inceptor. This paper looks into such possibility by designing and testing different tip configuration air terminals, i.e. sharp, blunt, flat, conical and concave. Tests in high voltage laboratory revealed that blunt air terminal has lower breakdown voltage and longer time to breakdown compared to other air terminals. This suggests that the performance of blunt rod is better than other rods. Based on the laboratory experimental studies, the modification of air terminal geometrical tip could be an alternative for future application specifically for the lightning protection of power stations against direct strokes.
first_indexed 2025-11-15T20:37:57Z
format Article
id utm-1644
institution Universiti Teknologi Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T20:37:57Z
publishDate 2005
recordtype eprints
repository_type Digital Repository
spelling utm-16442017-04-16T07:28:53Z http://eprints.utm.my/1644/ An account of a modified lightning protection system for power stations Ahmad, Hussein Ong, L. M. TK Electrical engineering. Electronics Nuclear engineering Power stations may face huge losses and damage when struck by lightning. Much effort has been carried out to find an alternative to the conventional lightning air terminal for direct protection to power stations. One of the alternative is to modify the tip configuration of conventional air terminals to enable it to be better inceptor. This paper looks into such possibility by designing and testing different tip configuration air terminals, i.e. sharp, blunt, flat, conical and concave. Tests in high voltage laboratory revealed that blunt air terminal has lower breakdown voltage and longer time to breakdown compared to other air terminals. This suggests that the performance of blunt rod is better than other rods. Based on the laboratory experimental studies, the modification of air terminal geometrical tip could be an alternative for future application specifically for the lightning protection of power stations against direct strokes. 2005-11-29 Article PeerReviewed application/pdf en http://eprints.utm.my/1644/1/hussein05_Account_of_modified_lightning.pdf Ahmad, Hussein and Ong, L. M. (2005) An account of a modified lightning protection system for power stations. The 7th International COnference on Power Engineering, 2 . pp. 609-613. http://ieeexplore.ieee.org/document/1627269/
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Ahmad, Hussein
Ong, L. M.
An account of a modified lightning protection system for power stations
title An account of a modified lightning protection system for power stations
title_full An account of a modified lightning protection system for power stations
title_fullStr An account of a modified lightning protection system for power stations
title_full_unstemmed An account of a modified lightning protection system for power stations
title_short An account of a modified lightning protection system for power stations
title_sort account of a modified lightning protection system for power stations
topic TK Electrical engineering. Electronics Nuclear engineering
url http://eprints.utm.my/1644/
http://eprints.utm.my/1644/
http://eprints.utm.my/1644/1/hussein05_Account_of_modified_lightning.pdf