Column design with semi-rigid end frame

The strength and the stability of the steel frames is mostly influenced by the connection strength and stiffness. Usually in conventional analysis, the convenient and easy way to design the connection is by using pin or rigid connection. But, in actual the connection is behaved most likely between t...

Full description

Bibliographic Details
Main Author: Wan Jusoh, Wan Hidayatul Hak
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:http://eprints.utm.my/11235/
http://eprints.utm.my/11235/6/WanHidayatulHakMFKA2010.pdf
_version_ 1848892295862026240
author Wan Jusoh, Wan Hidayatul Hak
author_facet Wan Jusoh, Wan Hidayatul Hak
author_sort Wan Jusoh, Wan Hidayatul Hak
building UTeM Institutional Repository
collection Online Access
description The strength and the stability of the steel frames is mostly influenced by the connection strength and stiffness. Usually in conventional analysis, the convenient and easy way to design the connection is by using pin or rigid connection. But, in actual the connection is behaved most likely between these two (2) connections. The connection called semi-rigid which possessed a certain degree of rotational restraint. Years ago, numerous studies have been conducted to investigate the behavior of column and developed the design method on semi-rigid connection for braced and unbraced frames. However, semi-rigid connection has not been adopted very enthusiastically by the structural designer due to the lack of confidence about it behavior. They are convenient in using the conventional design method based on BS 5950 [1], Eurocode [2, 3] or AISC. Recently there was a study which proposed the easy way to design column which neglect moment transfer to column known as simplified apin approach [4, 5]. This study is conducted to look into the column at ultimate limit state with the aid of computer software name LUSAS Analyst and to look the reliability of simplified apin approach as a straightforward method compared to conventional design. From the result of this study, it found that the column strength is affected by the stiffness of the connection and the simplified apin approach also reliable to use in design the column without transferring the moment. The value of apin always give more than unity which mean it is reliable.
first_indexed 2025-11-15T21:11:36Z
format Thesis
id utm-11235
institution Universiti Teknologi Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T21:11:36Z
publishDate 2010
recordtype eprints
repository_type Digital Repository
spelling utm-112352017-09-26T04:50:10Z http://eprints.utm.my/11235/ Column design with semi-rigid end frame Wan Jusoh, Wan Hidayatul Hak TA Engineering (General). Civil engineering (General) The strength and the stability of the steel frames is mostly influenced by the connection strength and stiffness. Usually in conventional analysis, the convenient and easy way to design the connection is by using pin or rigid connection. But, in actual the connection is behaved most likely between these two (2) connections. The connection called semi-rigid which possessed a certain degree of rotational restraint. Years ago, numerous studies have been conducted to investigate the behavior of column and developed the design method on semi-rigid connection for braced and unbraced frames. However, semi-rigid connection has not been adopted very enthusiastically by the structural designer due to the lack of confidence about it behavior. They are convenient in using the conventional design method based on BS 5950 [1], Eurocode [2, 3] or AISC. Recently there was a study which proposed the easy way to design column which neglect moment transfer to column known as simplified apin approach [4, 5]. This study is conducted to look into the column at ultimate limit state with the aid of computer software name LUSAS Analyst and to look the reliability of simplified apin approach as a straightforward method compared to conventional design. From the result of this study, it found that the column strength is affected by the stiffness of the connection and the simplified apin approach also reliable to use in design the column without transferring the moment. The value of apin always give more than unity which mean it is reliable. 2010-04 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/11235/6/WanHidayatulHakMFKA2010.pdf Wan Jusoh, Wan Hidayatul Hak (2010) Column design with semi-rigid end frame. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.
spellingShingle TA Engineering (General). Civil engineering (General)
Wan Jusoh, Wan Hidayatul Hak
Column design with semi-rigid end frame
title Column design with semi-rigid end frame
title_full Column design with semi-rigid end frame
title_fullStr Column design with semi-rigid end frame
title_full_unstemmed Column design with semi-rigid end frame
title_short Column design with semi-rigid end frame
title_sort column design with semi-rigid end frame
topic TA Engineering (General). Civil engineering (General)