Seismic behavior of tall building structures by friction damper

Large-magnitude long-distance earthquakes generated from Sumatra have significant potential engineering implications in Singapore and Malaysia Peninsula due to accentuation by resonance in buildings. Historical seismicity data of the region covering the past 100 years shows numerous occasions when l...

Full description

Bibliographic Details
Main Author: Shoushtari, Abdollah Vaez
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:http://eprints.utm.my/11048/
http://eprints.utm.my/11048/4/AbdollahVaezShoushtariMFKA2010.pdf
_version_ 1848892244906475520
author Shoushtari, Abdollah Vaez
author_facet Shoushtari, Abdollah Vaez
author_sort Shoushtari, Abdollah Vaez
building UTeM Institutional Repository
collection Online Access
description Large-magnitude long-distance earthquakes generated from Sumatra have significant potential engineering implications in Singapore and Malaysia Peninsula due to accentuation by resonance in buildings. Historical seismicity data of the region covering the past 100 years shows numerous occasions when low-intensity seismic waves reached Peninsular and hence no seismic provisions have been incorporated into building regulations to date. If part of input energy due to earthquake could be dissipated through special devices which can be easily be replaced, as necessary, after an earthquake, the structural damage could be reduced. These devices can be classified into three categories: viscous and viscoelastic dampers, metallic dampers, and friction dampers. The purpose of this study is to evaluate the seismic behavior of tall building structures by friction damper. The finite element modeling technique (SAP2000 Software) is used in this study to learn the behavior of structure equipped by friction dampers. Three different methods of analyzing (Free vibration, Response spectrum, and Time History analysis) have been done to achieve this purpose. In general, this study indicates that the response of structure such as story drifts, axial load of columns and beams, shear load and bending moment of beams, and base shear can be dramatically reduced by using friction damper devices. In addition, this study indicates that the seismic risks due to large-magnitude, long-distance earthquakes generated from Sumatra should be considered for the tall buildings in Malaysia and the application of the seismic retrofitting to existing buildings is much needed to safeguard structure from external peak ground acceleration intensity.
first_indexed 2025-11-15T21:10:47Z
format Thesis
id utm-11048
institution Universiti Teknologi Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T21:10:47Z
publishDate 2010
recordtype eprints
repository_type Digital Repository
spelling utm-110482017-09-20T08:44:10Z http://eprints.utm.my/11048/ Seismic behavior of tall building structures by friction damper Shoushtari, Abdollah Vaez TA Engineering (General). Civil engineering (General) Large-magnitude long-distance earthquakes generated from Sumatra have significant potential engineering implications in Singapore and Malaysia Peninsula due to accentuation by resonance in buildings. Historical seismicity data of the region covering the past 100 years shows numerous occasions when low-intensity seismic waves reached Peninsular and hence no seismic provisions have been incorporated into building regulations to date. If part of input energy due to earthquake could be dissipated through special devices which can be easily be replaced, as necessary, after an earthquake, the structural damage could be reduced. These devices can be classified into three categories: viscous and viscoelastic dampers, metallic dampers, and friction dampers. The purpose of this study is to evaluate the seismic behavior of tall building structures by friction damper. The finite element modeling technique (SAP2000 Software) is used in this study to learn the behavior of structure equipped by friction dampers. Three different methods of analyzing (Free vibration, Response spectrum, and Time History analysis) have been done to achieve this purpose. In general, this study indicates that the response of structure such as story drifts, axial load of columns and beams, shear load and bending moment of beams, and base shear can be dramatically reduced by using friction damper devices. In addition, this study indicates that the seismic risks due to large-magnitude, long-distance earthquakes generated from Sumatra should be considered for the tall buildings in Malaysia and the application of the seismic retrofitting to existing buildings is much needed to safeguard structure from external peak ground acceleration intensity. 2010-07 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/11048/4/AbdollahVaezShoushtariMFKA2010.pdf Shoushtari, Abdollah Vaez (2010) Seismic behavior of tall building structures by friction damper. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:70670?site_name=Restricted Repository
spellingShingle TA Engineering (General). Civil engineering (General)
Shoushtari, Abdollah Vaez
Seismic behavior of tall building structures by friction damper
title Seismic behavior of tall building structures by friction damper
title_full Seismic behavior of tall building structures by friction damper
title_fullStr Seismic behavior of tall building structures by friction damper
title_full_unstemmed Seismic behavior of tall building structures by friction damper
title_short Seismic behavior of tall building structures by friction damper
title_sort seismic behavior of tall building structures by friction damper
topic TA Engineering (General). Civil engineering (General)
url http://eprints.utm.my/11048/
http://eprints.utm.my/11048/