Experimental design, analysis and simulation of human-like hand tremor behaviour
The purpose of this study is to investigate human hand tremor behaviour in postural condition. In order to achieve the objective, an experimental rig is fabricated as an apparatus to emulate the tremor behaviour. The experimental rig is designed to induce vibration along the dummy hand-arm in postur...
| Main Author: | As’Arry, Azizan |
|---|---|
| Format: | Thesis |
| Language: | English |
| Published: |
2009
|
| Subjects: | |
| Online Access: | http://eprints.utm.my/10618/ http://eprints.utm.my/10618/6/AzizanAsarryMFKM2010.pdf |
Similar Items
Development of hand-arm model rig for tremor excitation
by: As'arry, A., et al.
Published: (2008)
by: As'arry, A., et al.
Published: (2008)
Design, fabricate and analysis of tremor test rig to emulate human hand tremor
by: Jamaludin, H., et al.
Published: (2022)
by: Jamaludin, H., et al.
Published: (2022)
A Comparison Of The Different Algorithms For Essential Tremor And Parkinson’s Disease Tremor Differentiation Based On Hand Tremor
by: Boey, Keen Huang
Published: (2018)
by: Boey, Keen Huang
Published: (2018)
Suppression of Parkinson's hand-like tremor using fuzzy-PID controller
by: As'arry, Azizan, et al.
Published: (2016)
by: As'arry, Azizan, et al.
Published: (2016)
Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm
by: As'arry, Azizan, et al.
Published: (2017)
by: As'arry, Azizan, et al.
Published: (2017)
Active tremor control on human hand tremor test rig model using P+fuzzy logic controller
by: Jamaludin, Hafiz
Published: (2019)
by: Jamaludin, Hafiz
Published: (2019)
Intelligent glove for suppression of resting tremor in parkinson’s disease
by: M. Zulkefli, Adibah, et al.
Published: (2019)
by: M. Zulkefli, Adibah, et al.
Published: (2019)
Tremor quantification and its measurements using shimmer
by: Musab, Reem, et al.
Published: (2019)
by: Musab, Reem, et al.
Published: (2019)
Experimental analysis and simulation of catalytic converters
by: Mohiuddin, A. K. M.
Published: (2011)
by: Mohiuddin, A. K. M.
Published: (2011)
Simulation and experimental analysis of a suspension system
by: Ab Ghani, Mohd. Satar
Published: (2006)
by: Ab Ghani, Mohd. Satar
Published: (2006)
Characterisation of dynamic behaviour of vertical machining centre components: experimental and simulation approaches
by: Patwari, Muhammed Anayet Ullah, et al.
Published: (2009)
by: Patwari, Muhammed Anayet Ullah, et al.
Published: (2009)
Simulation and experimental analysis of an active vehicle suspension system
by: Ahmad @ Manap, Mohd. Rizal
Published: (2007)
by: Ahmad @ Manap, Mohd. Rizal
Published: (2007)
Development of wearable real time monitoring system for hand tremor through wireless communication
by: Teoh, Xin Ni, et al.
Published: (2021)
by: Teoh, Xin Ni, et al.
Published: (2021)
Speeding Driving Behaviour: Age And Gender Experimental Analysis
by: S. H., Teo, et al.
Published: (2015)
by: S. H., Teo, et al.
Published: (2015)
Design and development of noise reduction device for hand drilling machine
by: Wan Hafizee , Wan Zulkiflee
Published: (2012)
by: Wan Hafizee , Wan Zulkiflee
Published: (2012)
Design And Development Of Biomechanics Calculation Software For Hand Movement
by: Wan Ismail Khairudin, Wan Ahmad Firdaus
Published: (2005)
by: Wan Ismail Khairudin, Wan Ahmad Firdaus
Published: (2005)
Evaluation Of A Two Stroke Compressed Natural Gas Mixer
Design By Simulation And Experimental Techniques
by: D., Ramasamy, et al.
Published: (2010)
by: D., Ramasamy, et al.
Published: (2010)
User-Centred Design Approach in
Designing Motorcycle Tire Dismounting
Tool for One-Handed User
by: Sudin, Mohd Nizam
Published: (2013)
by: Sudin, Mohd Nizam
Published: (2013)
Finite element and experimental analysis of dynamic behaviour of Vertical Machining Centre Components by Modal Analysis
by: Patwari, Muhammed Anayet Ullah, et al.
Published: (2009)
by: Patwari, Muhammed Anayet Ullah, et al.
Published: (2009)
Experimental and simulation results of cylindrical shell buckling
by: Shah, Qasim Hussain, et al.
Published: (2011)
by: Shah, Qasim Hussain, et al.
Published: (2011)
Correlation of Numerical and Experimental Analysis for Dynamic Behaviour of a body-in-white (BIW) Structure
by: N. A. Z., Abdullah, et al.
Published: (2017)
by: N. A. Z., Abdullah, et al.
Published: (2017)
Holding, grasping and sensing of prosthetic robot arm like a real human hand, a journey beyond limits: An extensive review
by: Babu, Devin, et al.
Published: (2022)
by: Babu, Devin, et al.
Published: (2022)
Experimental analysis to determine the relationship between noise and back pressure for muffler design – Part II: Experimental results
by: Mohiuddin, A. K. M.
Published: (2011)
by: Mohiuddin, A. K. M.
Published: (2011)
Comparative Evaluation Of A Two Stroke Compressed Natural Gas Mixer Design Using Simulation And Experimental Techniques
by: D., Ramasamy, et al.
Published: (2008)
by: D., Ramasamy, et al.
Published: (2008)
Modeling, simulation and experimental verification of hydraulic servo system
by: Anis Syarliza, Ahmad
Published: (2013)
by: Anis Syarliza, Ahmad
Published: (2013)
The Effect of Thermal Perturbation on a Polymer Material’s Tensile Test via Simulation and Experimental Analysis
by: Sazali, M.Q., et al.
Published: (2017)
by: Sazali, M.Q., et al.
Published: (2017)
International regulation of vehicle emissions control rules and its influence on academic engine development experimental study and vehicle manufacturing
by: Pshtiwan, M. Sharif, et al.
Published: (2019)
by: Pshtiwan, M. Sharif, et al.
Published: (2019)
Influence of hand movement on skin deformation: a therapeutic glove design perspective
by: Nasir, Siti Hana, et al.
Published: (2017)
by: Nasir, Siti Hana, et al.
Published: (2017)
Experimental and numerical simulation of hollow structure under compression loading
by: Abdullah, Kassim Abdulrahman, et al.
Published: (2012)
by: Abdullah, Kassim Abdulrahman, et al.
Published: (2012)
Modeling, simulation and experimental verification of variable parameter of suspension spring
by: Wan Ahmad Syafiq, Wan Ghafar
Published: (2013)
by: Wan Ahmad Syafiq, Wan Ghafar
Published: (2013)
Hand blood vessels pattern recognition
by: Tan, Xuan Qing
Published: (2023)
by: Tan, Xuan Qing
Published: (2023)
Design Optimization Using Numerical Simulation And Experimental Of Wind Energy Harvester Unit From Exhaust Fan
by: Adnan, Muhammad Zikri
Published: (2019)
by: Adnan, Muhammad Zikri
Published: (2019)
Design Of Mathematical Model For Locomotion Control Of Snake-Like Robot
by: Bakar, Norhayati Abu
Published: (2017)
by: Bakar, Norhayati Abu
Published: (2017)
Experimental analysis of indoor air quality for human comfort in vehicle cabin / Siti Nor' Ain Mokhtar
by: Siti Nor'Ain, Mokhtar
Published: (2021)
by: Siti Nor'Ain, Mokhtar
Published: (2021)
Experimental Simulation on the Effect of Leakage of Steam to the Heat Rate of a Plant
by: Sulaiman, S. A., et al.
Published: (2008)
by: Sulaiman, S. A., et al.
Published: (2008)
Experimental analysis to determine the relationship between noise and back pressure for muffler design – Part I: Muffler design requirements
by: Mohiuddin, A. K. M.
Published: (2011)
by: Mohiuddin, A. K. M.
Published: (2011)
Design and development of an assistive hand orthosis for hand and finger motor training
by: Wong, Chi Heim
Published: (2024)
by: Wong, Chi Heim
Published: (2024)
Experimental and Simulation Study on Steam Gasification of Phoenix-Dactylifera Date Palm Seeds
by: M. E., Babiker, et al.
Published: (2016)
by: M. E., Babiker, et al.
Published: (2016)
Drag analysis of an aircraft wing model and without bird feather like winglet
by: Hossain, Altab, et al.
Published: (2012)
by: Hossain, Altab, et al.
Published: (2012)
Unclean hand detection machine using vision sensor
by: Rawaida , Jaafar
Published: (2012)
by: Rawaida , Jaafar
Published: (2012)
Similar Items
-
Development of hand-arm model rig for tremor excitation
by: As'arry, A., et al.
Published: (2008) -
Design, fabricate and analysis of tremor test rig to emulate human hand tremor
by: Jamaludin, H., et al.
Published: (2022) -
A Comparison Of The Different Algorithms For Essential Tremor And Parkinson’s Disease Tremor Differentiation Based On Hand Tremor
by: Boey, Keen Huang
Published: (2018) -
Suppression of Parkinson's hand-like tremor using fuzzy-PID controller
by: As'arry, Azizan, et al.
Published: (2016) -
Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm
by: As'arry, Azizan, et al.
Published: (2017)