Indoor thermal performance of an office building using Conventional Brick Versus Interlocking Compressed Earth Brick (ICEB) wall

In recent years, the growing interest in using earth as modern wall material has mushroomed. However, the study on its indoor thermal environmental impact is still lacking Thus, this study was meant to investigate and compare the resulting indoor thermal performance of an office building d...

Full description

Bibliographic Details
Main Authors: Abdullah, Abd Halid, Abu Bakar, Siti Khatijah, Abdul Rahman*, Ismail
Format: Article
Language:English
Published: ZW Publisher 2013
Subjects:
Online Access:http://eprints.uthm.edu.my/8083/
http://eprints.uthm.edu.my/8083/1/J5984_654ed8172ddd89a9a160d89fc061a454.pdf
_version_ 1848889294266040320
author Abdullah, Abd Halid
Abu Bakar, Siti Khatijah
Abdul Rahman*, Ismail
author_facet Abdullah, Abd Halid
Abu Bakar, Siti Khatijah
Abdul Rahman*, Ismail
author_sort Abdullah, Abd Halid
building UTHM Institutional Repository
collection Online Access
description In recent years, the growing interest in using earth as modern wall material has mushroomed. However, the study on its indoor thermal environmental impact is still lacking Thus, this study was meant to investigate and compare the resulting indoor thermal performance of an office building due to common brick (CB) and interlocking compressed earth brick (ICEB) as wall materials. The comparison was based on the results of thermal simulation using ECOTECT program. It was found that by using ICEB for wall construction could possibly reduce the indoor operative temperature of office building by 1°C during the day. Moreover, the temperature distribution indicates that the percentage of indoor operative temperature remains in comfort condition during the working hours increase at about 22% on the ground floor and 30% on the first floor respectively, throughout the year. It is evident that ICEB provides a better indoor thermal performance than that of CB, and thus it has greater potential as alternative wall material in improving the indoor environmental condition during the day particularly in office building.
first_indexed 2025-11-15T20:23:53Z
format Article
id uthm-8083
institution Universiti Tun Hussein Onn Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T20:23:53Z
publishDate 2013
publisher ZW Publisher
recordtype eprints
repository_type Digital Repository
spelling uthm-80832022-12-06T02:57:31Z http://eprints.uthm.edu.my/8083/ Indoor thermal performance of an office building using Conventional Brick Versus Interlocking Compressed Earth Brick (ICEB) wall Abdullah, Abd Halid Abu Bakar, Siti Khatijah Abdul Rahman*, Ismail T Technology (General) In recent years, the growing interest in using earth as modern wall material has mushroomed. However, the study on its indoor thermal environmental impact is still lacking Thus, this study was meant to investigate and compare the resulting indoor thermal performance of an office building due to common brick (CB) and interlocking compressed earth brick (ICEB) as wall materials. The comparison was based on the results of thermal simulation using ECOTECT program. It was found that by using ICEB for wall construction could possibly reduce the indoor operative temperature of office building by 1°C during the day. Moreover, the temperature distribution indicates that the percentage of indoor operative temperature remains in comfort condition during the working hours increase at about 22% on the ground floor and 30% on the first floor respectively, throughout the year. It is evident that ICEB provides a better indoor thermal performance than that of CB, and thus it has greater potential as alternative wall material in improving the indoor environmental condition during the day particularly in office building. ZW Publisher 2013 Article PeerReviewed text en http://eprints.uthm.edu.my/8083/1/J5984_654ed8172ddd89a9a160d89fc061a454.pdf Abdullah, Abd Halid and Abu Bakar, Siti Khatijah and Abdul Rahman*, Ismail (2013) Indoor thermal performance of an office building using Conventional Brick Versus Interlocking Compressed Earth Brick (ICEB) wall. International Journal of Construction Technology and Management, 1 (1). pp. 22-27.
spellingShingle T Technology (General)
Abdullah, Abd Halid
Abu Bakar, Siti Khatijah
Abdul Rahman*, Ismail
Indoor thermal performance of an office building using Conventional Brick Versus Interlocking Compressed Earth Brick (ICEB) wall
title Indoor thermal performance of an office building using Conventional Brick Versus Interlocking Compressed Earth Brick (ICEB) wall
title_full Indoor thermal performance of an office building using Conventional Brick Versus Interlocking Compressed Earth Brick (ICEB) wall
title_fullStr Indoor thermal performance of an office building using Conventional Brick Versus Interlocking Compressed Earth Brick (ICEB) wall
title_full_unstemmed Indoor thermal performance of an office building using Conventional Brick Versus Interlocking Compressed Earth Brick (ICEB) wall
title_short Indoor thermal performance of an office building using Conventional Brick Versus Interlocking Compressed Earth Brick (ICEB) wall
title_sort indoor thermal performance of an office building using conventional brick versus interlocking compressed earth brick (iceb) wall
topic T Technology (General)
url http://eprints.uthm.edu.my/8083/
http://eprints.uthm.edu.my/8083/1/J5984_654ed8172ddd89a9a160d89fc061a454.pdf