Building energy performance a case study at G2 Building UTHM

Improper energy consumption has become a concern among the building owners. To ensure proper energy consumption of the building, it has become a practice to conduct building energy performance study. The study allows the building owner to confirm possible ineffective energy utilization of the buildi...

Full description

Bibliographic Details
Main Authors: Abdullah, Kamil, Mohamad, Mohd Hafiz
Format: Article
Language:English
Published: Penerbit Akademia Baru 2018
Subjects:
Online Access:http://eprints.uthm.edu.my/5180/
http://eprints.uthm.edu.my/5180/1/AJ%202018%20%28851%29%20Building%20energy%20performance%20a%20case%20study%20at%20G2%20Building%20UTHM.pdf
_version_ 1848888487097401344
author Abdullah, Kamil
Mohamad, Mohd Hafiz
author_facet Abdullah, Kamil
Mohamad, Mohd Hafiz
author_sort Abdullah, Kamil
building UTHM Institutional Repository
collection Online Access
description Improper energy consumption has become a concern among the building owners. To ensure proper energy consumption of the building, it has become a practice to conduct building energy performance study. The study allows the building owner to confirm possible ineffective energy utilization of the building. This paper presents a quantitative analysis of a building performance for G2 Building in Universiti Tun Hussein Onn Malaysia (UTHM) for a duration from August 2016 until March 2017. The study is based on collected electricity consumption data for the interval of 30 minutes every day throughout the study period. Building Energy Index (BEI) and Energy Intensity Index (EII) were used as building performance tools. The calculated BEI is 254.24 kWh/m2/year which is far beyond a minimum of 150 kWh/m2/year for nonresidential building in order to achieve a point by Green Building Index (GBI) of Malaysia. Meanwhile, the results on EII shows that a monthly amount of electricity energy was inconsistently consumed throughout a semester break and lecture period at a G2 Building. The present study attempts to address the building energy performance in G2 Building, hence to build up awareness on energy saving among building users.
first_indexed 2025-11-15T20:11:03Z
format Article
id uthm-5180
institution Universiti Tun Hussein Onn Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T20:11:03Z
publishDate 2018
publisher Penerbit Akademia Baru
recordtype eprints
repository_type Digital Repository
spelling uthm-51802022-01-06T04:04:35Z http://eprints.uthm.edu.my/5180/ Building energy performance a case study at G2 Building UTHM Abdullah, Kamil Mohamad, Mohd Hafiz TH Building construction TK2896-2985 Production of electricity by direct energy conversion Improper energy consumption has become a concern among the building owners. To ensure proper energy consumption of the building, it has become a practice to conduct building energy performance study. The study allows the building owner to confirm possible ineffective energy utilization of the building. This paper presents a quantitative analysis of a building performance for G2 Building in Universiti Tun Hussein Onn Malaysia (UTHM) for a duration from August 2016 until March 2017. The study is based on collected electricity consumption data for the interval of 30 minutes every day throughout the study period. Building Energy Index (BEI) and Energy Intensity Index (EII) were used as building performance tools. The calculated BEI is 254.24 kWh/m2/year which is far beyond a minimum of 150 kWh/m2/year for nonresidential building in order to achieve a point by Green Building Index (GBI) of Malaysia. Meanwhile, the results on EII shows that a monthly amount of electricity energy was inconsistently consumed throughout a semester break and lecture period at a G2 Building. The present study attempts to address the building energy performance in G2 Building, hence to build up awareness on energy saving among building users. Penerbit Akademia Baru 2018 Article PeerReviewed text en http://eprints.uthm.edu.my/5180/1/AJ%202018%20%28851%29%20Building%20energy%20performance%20a%20case%20study%20at%20G2%20Building%20UTHM.pdf Abdullah, Kamil and Mohamad, Mohd Hafiz (2018) Building energy performance a case study at G2 Building UTHM. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 50 (2). pp. 161-169. ISSN 2289-7879
spellingShingle TH Building construction
TK2896-2985 Production of electricity by direct energy conversion
Abdullah, Kamil
Mohamad, Mohd Hafiz
Building energy performance a case study at G2 Building UTHM
title Building energy performance a case study at G2 Building UTHM
title_full Building energy performance a case study at G2 Building UTHM
title_fullStr Building energy performance a case study at G2 Building UTHM
title_full_unstemmed Building energy performance a case study at G2 Building UTHM
title_short Building energy performance a case study at G2 Building UTHM
title_sort building energy performance a case study at g2 building uthm
topic TH Building construction
TK2896-2985 Production of electricity by direct energy conversion
url http://eprints.uthm.edu.my/5180/
http://eprints.uthm.edu.my/5180/1/AJ%202018%20%28851%29%20Building%20energy%20performance%20a%20case%20study%20at%20G2%20Building%20UTHM.pdf