Assessment of energy saving potential and lighting system in teaching building

Energy consumption and the potential for energy savings had become more intensive in public buildings in order to improve energy performance. This case study was identified the current occupancy, lighting use patterns and lighting performance in G3 Block B teaching building where most of the teachin...

Full description

Bibliographic Details
Main Authors: Awang, Mariah, C.S, Tham, Mohd Basir Ruddin, Nurhanis, Abdul Rahman, Mohamad Ashraf, Hamidon, Nuramidah, Ahmad, Faridahanim, Musa, Kamaruzaman, Nagapan, Sasitharan, Abdul Rahman, Mohd Shahril
Format: Article
Language:English
Published: Penerbit Akademia Baru 2020
Subjects:
Online Access:http://eprints.uthm.edu.my/5090/
http://eprints.uthm.edu.my/5090/1/AJ%202020%20%2888%29.pdf
_version_ 1848888460993101824
author Awang, Mariah
C.S, Tham
Mohd Basir Ruddin, Nurhanis
Abdul Rahman, Mohamad Ashraf
Hamidon, Nuramidah
Ahmad, Faridahanim
Musa, Kamaruzaman
Nagapan, Sasitharan
Abdul Rahman, Mohd Shahril
author_facet Awang, Mariah
C.S, Tham
Mohd Basir Ruddin, Nurhanis
Abdul Rahman, Mohamad Ashraf
Hamidon, Nuramidah
Ahmad, Faridahanim
Musa, Kamaruzaman
Nagapan, Sasitharan
Abdul Rahman, Mohd Shahril
author_sort Awang, Mariah
building UTHM Institutional Repository
collection Online Access
description Energy consumption and the potential for energy savings had become more intensive in public buildings in order to improve energy performance. This case study was identified the current occupancy, lighting use patterns and lighting performance in G3 Block B teaching building where most of the teaching rooms were located in University Tun Hussein Onn Malaysia. In order to determine the energy saving potential and strategies for lighting system in the building, a series of data collection were conducted to the effects of occupancy and lighting use patterns to display the lighting energy consumption and lighting energy waste of the case study building. The findings of this study displayed lighting use patterns varied among all the investigated lecture rooms at which 31% of lighting load was wasted and 13% of lighting load misused by the building users were recorded. Moreover, the result of lighting performance of the lecture room obtained was met the recommended average illuminance level (300-500 lux) of lighting for working interiors as classroom in MS 1525:2007. In addition, the perception, awareness and practices of energy conservation behavior on lighting of the building user were also studied through structured questionnaire. With regard to the findings of questionnaire in this study, the responses indicated that most of the respondents agreed they were at good perception, awareness and practices on their energy conservation behavior on lighting. Based on the various data obtained in this project, the energy and cost saving potential strategies were suggested for instances the structural energy conservation measures and non-structural energy conservation measures to improve the usage and efficiency of the lighting system in the teaching building towards energy conservation.
first_indexed 2025-11-15T20:10:39Z
format Article
id uthm-5090
institution Universiti Tun Hussein Onn Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T20:10:39Z
publishDate 2020
publisher Penerbit Akademia Baru
recordtype eprints
repository_type Digital Repository
spelling uthm-50902022-01-05T06:32:14Z http://eprints.uthm.edu.my/5090/ Assessment of energy saving potential and lighting system in teaching building Awang, Mariah C.S, Tham Mohd Basir Ruddin, Nurhanis Abdul Rahman, Mohamad Ashraf Hamidon, Nuramidah Ahmad, Faridahanim Musa, Kamaruzaman Nagapan, Sasitharan Abdul Rahman, Mohd Shahril T Technology (General) TJ163.13-163.25 Power resources Energy consumption and the potential for energy savings had become more intensive in public buildings in order to improve energy performance. This case study was identified the current occupancy, lighting use patterns and lighting performance in G3 Block B teaching building where most of the teaching rooms were located in University Tun Hussein Onn Malaysia. In order to determine the energy saving potential and strategies for lighting system in the building, a series of data collection were conducted to the effects of occupancy and lighting use patterns to display the lighting energy consumption and lighting energy waste of the case study building. The findings of this study displayed lighting use patterns varied among all the investigated lecture rooms at which 31% of lighting load was wasted and 13% of lighting load misused by the building users were recorded. Moreover, the result of lighting performance of the lecture room obtained was met the recommended average illuminance level (300-500 lux) of lighting for working interiors as classroom in MS 1525:2007. In addition, the perception, awareness and practices of energy conservation behavior on lighting of the building user were also studied through structured questionnaire. With regard to the findings of questionnaire in this study, the responses indicated that most of the respondents agreed they were at good perception, awareness and practices on their energy conservation behavior on lighting. Based on the various data obtained in this project, the energy and cost saving potential strategies were suggested for instances the structural energy conservation measures and non-structural energy conservation measures to improve the usage and efficiency of the lighting system in the teaching building towards energy conservation. Penerbit Akademia Baru 2020 Article PeerReviewed text en http://eprints.uthm.edu.my/5090/1/AJ%202020%20%2888%29.pdf Awang, Mariah and C.S, Tham and Mohd Basir Ruddin, Nurhanis and Abdul Rahman, Mohamad Ashraf and Hamidon, Nuramidah and Ahmad, Faridahanim and Musa, Kamaruzaman and Nagapan, Sasitharan and Abdul Rahman, Mohd Shahril (2020) Assessment of energy saving potential and lighting system in teaching building. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 65 (1). pp. 159-169. ISSN 2289-7879
spellingShingle T Technology (General)
TJ163.13-163.25 Power resources
Awang, Mariah
C.S, Tham
Mohd Basir Ruddin, Nurhanis
Abdul Rahman, Mohamad Ashraf
Hamidon, Nuramidah
Ahmad, Faridahanim
Musa, Kamaruzaman
Nagapan, Sasitharan
Abdul Rahman, Mohd Shahril
Assessment of energy saving potential and lighting system in teaching building
title Assessment of energy saving potential and lighting system in teaching building
title_full Assessment of energy saving potential and lighting system in teaching building
title_fullStr Assessment of energy saving potential and lighting system in teaching building
title_full_unstemmed Assessment of energy saving potential and lighting system in teaching building
title_short Assessment of energy saving potential and lighting system in teaching building
title_sort assessment of energy saving potential and lighting system in teaching building
topic T Technology (General)
TJ163.13-163.25 Power resources
url http://eprints.uthm.edu.my/5090/
http://eprints.uthm.edu.my/5090/1/AJ%202020%20%2888%29.pdf