Real time power control strategy for output power for single phase inverter-linear load

Power electronics have been widely used in many applications due to its reliability in controller. This project is to describe and test the real time power control strategy for output power for inverter-linear load connection. The current control strategy was adapted in controlling the output power...

Full description

Bibliographic Details
Main Author: Zaidan, Ahmed Naji
Format: Thesis
Language:English
English
English
Published: 2019
Subjects:
Online Access:http://eprints.uthm.edu.my/441/
http://eprints.uthm.edu.my/441/1/24p%20AHMAD%20NAJI%20ZAIDAN.pdf
http://eprints.uthm.edu.my/441/2/AHMAD%20NAJI%20ZAIDAN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/441/3/AHMAD%20NAJI%20ZAIDAN%20WATERMARK.pdf
_version_ 1848887194640449536
author Zaidan, Ahmed Naji
author_facet Zaidan, Ahmed Naji
author_sort Zaidan, Ahmed Naji
building UTHM Institutional Repository
collection Online Access
description Power electronics have been widely used in many applications due to its reliability in controller. This project is to describe and test the real time power control strategy for output power for inverter-linear load connection. The current control strategy was adapted in controlling the output power of inverter to the resistive load. This was done by controlling the output current of the inverter. The output current was controlled by comparing between desired value with the target reference current. The feedback signal from the current output was processed by the microcontroller through the current sensor. The Texas Instrument C2000 microcontroller was used. The justification of this choice was its ability to convert the signal of the current sensor from analog to digital directly from the microcontroller. The controller used was developed from Proportional integral (PI) controller theory using the MATLAB SIMULINK software. At the end, the output power of the inverter was able to control the output current of the inverter as designed. The results obtained reflects a single phase inverter with a controlled output power at the desired value. This is an indication that the output current of inverter was controlled.
first_indexed 2025-11-15T19:50:31Z
format Thesis
id uthm-441
institution Universiti Tun Hussein Onn Malaysia
institution_category Local University
language English
English
English
last_indexed 2025-11-15T19:50:31Z
publishDate 2019
recordtype eprints
repository_type Digital Repository
spelling uthm-4412021-07-25T06:26:31Z http://eprints.uthm.edu.my/441/ Real time power control strategy for output power for single phase inverter-linear load Zaidan, Ahmed Naji TK1001-1841 Production of electric energy or power. Powerplants. Central stations Power electronics have been widely used in many applications due to its reliability in controller. This project is to describe and test the real time power control strategy for output power for inverter-linear load connection. The current control strategy was adapted in controlling the output power of inverter to the resistive load. This was done by controlling the output current of the inverter. The output current was controlled by comparing between desired value with the target reference current. The feedback signal from the current output was processed by the microcontroller through the current sensor. The Texas Instrument C2000 microcontroller was used. The justification of this choice was its ability to convert the signal of the current sensor from analog to digital directly from the microcontroller. The controller used was developed from Proportional integral (PI) controller theory using the MATLAB SIMULINK software. At the end, the output power of the inverter was able to control the output current of the inverter as designed. The results obtained reflects a single phase inverter with a controlled output power at the desired value. This is an indication that the output current of inverter was controlled. 2019-01 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/441/1/24p%20AHMAD%20NAJI%20ZAIDAN.pdf text en http://eprints.uthm.edu.my/441/2/AHMAD%20NAJI%20ZAIDAN%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/441/3/AHMAD%20NAJI%20ZAIDAN%20WATERMARK.pdf Zaidan, Ahmed Naji (2019) Real time power control strategy for output power for single phase inverter-linear load. Masters thesis, Universiti Tun Hussein Onn Malaysia.
spellingShingle TK1001-1841 Production of electric energy or power. Powerplants. Central stations
Zaidan, Ahmed Naji
Real time power control strategy for output power for single phase inverter-linear load
title Real time power control strategy for output power for single phase inverter-linear load
title_full Real time power control strategy for output power for single phase inverter-linear load
title_fullStr Real time power control strategy for output power for single phase inverter-linear load
title_full_unstemmed Real time power control strategy for output power for single phase inverter-linear load
title_short Real time power control strategy for output power for single phase inverter-linear load
title_sort real time power control strategy for output power for single phase inverter-linear load
topic TK1001-1841 Production of electric energy or power. Powerplants. Central stations
url http://eprints.uthm.edu.my/441/
http://eprints.uthm.edu.my/441/1/24p%20AHMAD%20NAJI%20ZAIDAN.pdf
http://eprints.uthm.edu.my/441/2/AHMAD%20NAJI%20ZAIDAN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/441/3/AHMAD%20NAJI%20ZAIDAN%20WATERMARK.pdf