A review on electrical capacitance tomography sensor development
Electrical Capacitance Tomography (ECT) detects changes in the distribution of transparency in enclosed areas or pipes. Until now, various methods have been used to determine the optimum ECT sensor for a particular application. Some important parameters that affect the sensitivity of the sensor cann...
| Main Authors: | , , , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Penerbit UTM Press
2015
|
| Subjects: | |
| Online Access: | http://eprints.uthm.edu.my/4223/ http://eprints.uthm.edu.my/4223/1/AJ%202017%20%28126%29%20A%20review%20on%20electrical%20capacitance.pdf |
| _version_ | 1848888229069062144 |
|---|---|
| author | Abd. Rahman, Noor Amizan Abdul Rahim, Ruzairi Mohd Nawi, Abdullah Leow, Pei Ling Pusppanathan, Jaysuman Mohamad, Elmy Johana Chan, Kok Seong Mohammad Din, Shahrulnizahani Nor Ayob, Nor Muzakkir Mohd Yunus, Fazlul Rahman |
| author_facet | Abd. Rahman, Noor Amizan Abdul Rahim, Ruzairi Mohd Nawi, Abdullah Leow, Pei Ling Pusppanathan, Jaysuman Mohamad, Elmy Johana Chan, Kok Seong Mohammad Din, Shahrulnizahani Nor Ayob, Nor Muzakkir Mohd Yunus, Fazlul Rahman |
| author_sort | Abd. Rahman, Noor Amizan |
| building | UTHM Institutional Repository |
| collection | Online Access |
| description | Electrical Capacitance Tomography (ECT) detects changes in the distribution of transparency in enclosed areas or pipes. Until now, various methods have been used to determine the optimum ECT sensor for a particular application. Some important parameters that affect the sensitivity of the sensor cannot be ignored. Design factors discussed in this paper study the needs in industry by producing the best image, without affecting the operation of the process. From previous studies many parameters influence the quality and effectiveness of an ECT sensor. The parameters that play important roles in ECT sensor design include the thickness and type of material in the pipe wall between the electrodes and the sensing zone, the thickness and material of the pipe wall separating the electrodes and the screen, the size of the electrodes, the guarding used, example radial guards or plane axial guards, and whether end guards are used. Other matters of concern regarding the dimension and the distance between the electrodes with guardians it is important design factor. Electrodes positioned either inside or outside the vessel will affect the cost factor design to the type of system to be used. This overview of the study is a basic guide for the essential requirements for an ECT sensor system design. |
| first_indexed | 2025-11-15T20:06:57Z |
| format | Article |
| id | uthm-4223 |
| institution | Universiti Tun Hussein Onn Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T20:06:57Z |
| publishDate | 2015 |
| publisher | Penerbit UTM Press |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | uthm-42232021-12-01T06:16:55Z http://eprints.uthm.edu.my/4223/ A review on electrical capacitance tomography sensor development Abd. Rahman, Noor Amizan Abdul Rahim, Ruzairi Mohd Nawi, Abdullah Leow, Pei Ling Pusppanathan, Jaysuman Mohamad, Elmy Johana Chan, Kok Seong Mohammad Din, Shahrulnizahani Nor Ayob, Nor Muzakkir Mohd Yunus, Fazlul Rahman TA401-492 Materials of engineering and construction. Mechanics of materials TK7800-8360 Electronics Electrical Capacitance Tomography (ECT) detects changes in the distribution of transparency in enclosed areas or pipes. Until now, various methods have been used to determine the optimum ECT sensor for a particular application. Some important parameters that affect the sensitivity of the sensor cannot be ignored. Design factors discussed in this paper study the needs in industry by producing the best image, without affecting the operation of the process. From previous studies many parameters influence the quality and effectiveness of an ECT sensor. The parameters that play important roles in ECT sensor design include the thickness and type of material in the pipe wall between the electrodes and the sensing zone, the thickness and material of the pipe wall separating the electrodes and the screen, the size of the electrodes, the guarding used, example radial guards or plane axial guards, and whether end guards are used. Other matters of concern regarding the dimension and the distance between the electrodes with guardians it is important design factor. Electrodes positioned either inside or outside the vessel will affect the cost factor design to the type of system to be used. This overview of the study is a basic guide for the essential requirements for an ECT sensor system design. Penerbit UTM Press 2015 Article PeerReviewed text en http://eprints.uthm.edu.my/4223/1/AJ%202017%20%28126%29%20A%20review%20on%20electrical%20capacitance.pdf Abd. Rahman, Noor Amizan and Abdul Rahim, Ruzairi and Mohd Nawi, Abdullah and Leow, Pei Ling and Pusppanathan, Jaysuman and Mohamad, Elmy Johana and Chan, Kok Seong and Mohammad Din, Shahrulnizahani and Nor Ayob, Nor Muzakkir and Mohd Yunus, Fazlul Rahman (2015) A review on electrical capacitance tomography sensor development. Jurnal Teknologi (Sciences & Engineering), 73 (3). pp. 35-41. ISSN 2180–3722 |
| spellingShingle | TA401-492 Materials of engineering and construction. Mechanics of materials TK7800-8360 Electronics Abd. Rahman, Noor Amizan Abdul Rahim, Ruzairi Mohd Nawi, Abdullah Leow, Pei Ling Pusppanathan, Jaysuman Mohamad, Elmy Johana Chan, Kok Seong Mohammad Din, Shahrulnizahani Nor Ayob, Nor Muzakkir Mohd Yunus, Fazlul Rahman A review on electrical capacitance tomography sensor development |
| title | A review on electrical capacitance tomography sensor development |
| title_full | A review on electrical capacitance tomography sensor development |
| title_fullStr | A review on electrical capacitance tomography sensor development |
| title_full_unstemmed | A review on electrical capacitance tomography sensor development |
| title_short | A review on electrical capacitance tomography sensor development |
| title_sort | review on electrical capacitance tomography sensor development |
| topic | TA401-492 Materials of engineering and construction. Mechanics of materials TK7800-8360 Electronics |
| url | http://eprints.uthm.edu.my/4223/ http://eprints.uthm.edu.my/4223/1/AJ%202017%20%28126%29%20A%20review%20on%20electrical%20capacitance.pdf |