Design and fabricating of an orthotic insole by using Kinect® XBOX gaming sensor scanner and 3D printer
This project is to design and fabricate of an orthotic insole by using Kinect® XBOX 360 gaming sensor scanner and 3D printer. In order to fulfill medical requirement, it was invented to help medical field to overcome their problem of high 3D scanner cost, handcrafted fabrication, inventory problem,...
| Main Author: | Burhan, Mohd Hafiz |
|---|---|
| Format: | Thesis |
| Language: | English English English |
| Published: |
2015
|
| Subjects: | |
| Online Access: | http://eprints.uthm.edu.my/1367/ http://eprints.uthm.edu.my/1367/2/MOHD%20HAFIZ%20BURHAN%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/1367/1/24p%20MOHD%20HAFIZ%20BURHAN.pdf http://eprints.uthm.edu.my/1367/3/MOHD%20HAFIZ%20BURHAN%20WATERMARK.pdf |
Similar Items
Designing an Orthotic Insole by Using Kinect® XBOX Gaming Sensor Scanner and Computer Aided Engineering Software
by: Mohd Hafiz, Burhan, et al.
Published: (2017)
by: Mohd Hafiz, Burhan, et al.
Published: (2017)
Development of 3D printed anthropomorphic radiotherapy head phantom using kinect® xbox 360® scanner
by: Zain, Nur Emirah Mohd
Published: (2021)
by: Zain, Nur Emirah Mohd
Published: (2021)
Limitation of mobile head CT scanner (ceretom) image quality in a neurosurgery center
by: Abdullah@ Yong, Ariz Chong@Chong Chee
Published: (2016)
by: Abdullah@ Yong, Ariz Chong@Chong Chee
Published: (2016)
Xbox Kinect™ represents high intensity exercise for adults with cystic fibrosis
by: Holmes, H., et al.
Published: (2013)
by: Holmes, H., et al.
Published: (2013)
Fabrication of low-cost, cementless femoral stem 316L stainless steel using investment casting technique
by: Baharuddin, Mohd Yusof, et al.
Published: (2014)
by: Baharuddin, Mohd Yusof, et al.
Published: (2014)
Analysis of blood flow in 3d heart valve model under steady state condition
by: Mohammad Iskandar, Othman
Published: (2012)
by: Mohammad Iskandar, Othman
Published: (2012)
Numerical analysis on simplified 2d model of heart valve leaflets during cardiac cycle
by: Lee, Xin Leong
Published: (2012)
by: Lee, Xin Leong
Published: (2012)
Randomized control study using vitamin d ( calcitriol) in preventing post total thyroidectomy transient hypocalcemia
by: Chung Ket, Lai
Published: (2011)
by: Chung Ket, Lai
Published: (2011)
Comparison of the effectiveness between c-mac d-blade and glidescope for tracheal intubation in patients with cervical spine immobilisation simulated by a semi-rigid collar
by: Che Wil, Farah Fatmawati
Published: (2015)
by: Che Wil, Farah Fatmawati
Published: (2015)
Implants for surgery - Components for partial and total knee joint prostheses - Part 1: Classification, definitions and designation of dimensions (ISO 7207-1:2007, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
Design and analysis of wheelchair in term of daily usage
by: Ahmad Muhaimin, Ismail
Published: (2012)
by: Ahmad Muhaimin, Ismail
Published: (2012)
Design and analysis of modular wheelchair for usage of handicap people
by: Mohd Amin, Mad Saad
Published: (2012)
by: Mohd Amin, Mad Saad
Published: (2012)
Designing a new concept of narrow dynamic compression plate (narrow DCP)
by: Mohd Shahrulnizal, Ghozali
Published: (2007)
by: Mohd Shahrulnizal, Ghozali
Published: (2007)
Designing a new concept of LC-DCP broad type bone plate
by: Muhammad Kamal Asyraf, Pubin
Published: (2007)
by: Muhammad Kamal Asyraf, Pubin
Published: (2007)
Implants for surgery - fundamental principles
by: Abdul razak, Norhayati, et al.
Published: (2010)
by: Abdul razak, Norhayati, et al.
Published: (2010)
Non-active surgical implants - joint replacement implants - specifice requirements for knee-joint replacement implants (ISO 21536:2007, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
Non-active surgical implants-joint replacement implants-particular requirements (ISO 21534:2007, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
Implants for surgery - active implantable medical devices - part 1: general requirements for safety, marking and for information to be provided by the manufacturer (ISO 14708-1:2000, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
Implants for surgery - hydroxyapatite - part 3: chemical analysis and characterization of crystallinity and phase purity (ISO 13779-3:2008, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
Implants for surgery - hydroxyapatite - part 2: coatings of hydroxyapatite (ISO 13779-2:2008, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
Implants for surgery - Hydroxyapatite - part 1: Ceramic Hydroxyapatite (ISO 13779-1:2008, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
Implants for surgery - in vitro evaluation for apatite-forming ability of implant materials (ISO 23317:2007, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
Implants for surgery - Hydroxyapatite - Part 4: Determination of coating adhesion strength (ISO 13779-4:2002, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
by: Abdul Razak, Noor Hayati, et al.
Published: (2010)
Implants for surgery - Measurements of open-circuit potential to assess corrosion behaviour of metallic implantable materials and medical devices over extended time periods (ISO 16429:2004, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
Implants for surgery - Ceramic materials based on yttria-stabilized tetragonal zirconia (Y-TZP) (ISO 13356:2008, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
Implants for surgery - skeletal pins and wires - part 3: Kirschner skeletal wires (ISO 5838-3:1993, MOD)
by: Abdul Razak, Noor Hayati, et al.
Published: (2015)
by: Abdul Razak, Noor Hayati, et al.
Published: (2015)
Implants for surgery - metallic materials-classification of microstructures for alpha+beta titanium alloy bars (ISO 20160:2006, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
Implants for surgery - skeletal pins and wires - part 2: Steinmann skeletal pins - Dimensions (ISO 5838-2:1991, MOD)
by: Abdul Razak, Noor Hayati, et al.
Published: (2015)
by: Abdul Razak, Noor Hayati, et al.
Published: (2015)
Implants for surgery - wear of total knee-joint prostheses - part 2: methods of measurement (ISO 14243-2:2009, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
Implants for surgery - wear of total knee-joint prostheses - part 1: loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test (ISO 14243-1:2009, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
Implants for surgery - wear of total knee-joint prostheses - part 3: loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test (ISO 14243-2:2004, COR. 1:2006, IDT)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
by: Abdul Razak, Noor Hayati, et al.
Published: (2011)
Six hole fracture fixation plates : Comparative mechanical properties study
by: Omar, Mohd Afian, et al.
Published: (2017)
by: Omar, Mohd Afian, et al.
Published: (2017)
Infant orbital osteotomy with ultrasonic surgical unit:
2 Cases
by: Abdul Rahman, Shaifulizan, et al.
Published: (2014)
by: Abdul Rahman, Shaifulizan, et al.
Published: (2014)
Preliminary report on spiegelberg pre and post-operative monitoring of severe head-injured patients who received decompressive craniectomy
by: Abdullah Jafri, Jafri, et al.
Published: (2005)
by: Abdullah Jafri, Jafri, et al.
Published: (2005)
Post traumatic cerebral oedema in severe head injury is related to intracranial pressure and
cerebral perfusion pressure but not to cerebral compliance
by: UdinNujaimin, Nujaimin, et al.
Published: (2009)
by: UdinNujaimin, Nujaimin, et al.
Published: (2009)
Chiari malformation - the role of posterior fossa decompression
by: Awang, Mohamed Saufi
Published: (2013)
by: Awang, Mohamed Saufi
Published: (2013)
Similar Items
-
Designing an Orthotic Insole by Using Kinect® XBOX Gaming Sensor Scanner and Computer Aided Engineering Software
by: Mohd Hafiz, Burhan, et al.
Published: (2017) -
Development of 3D printed anthropomorphic radiotherapy head phantom using kinect® xbox 360® scanner
by: Zain, Nur Emirah Mohd
Published: (2021) -
Limitation of mobile head CT scanner (ceretom) image quality in a neurosurgery center
by: Abdullah@ Yong, Ariz Chong@Chong Chee
Published: (2016) -
Xbox Kinect™ represents high intensity exercise for adults with cystic fibrosis
by: Holmes, H., et al.
Published: (2013) -
Fabrication of low-cost, cementless femoral stem 316L stainless steel using investment casting technique
by: Baharuddin, Mohd Yusof, et al.
Published: (2014)