Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP)
This study presents the outcomes of the performance evaluation simulation residual voltage output resulting from lightning arrestors IEEE Recommended model. This simulation uses software Alternative Transient Program - Electromagnetic transients Programmed (ATP-EMTP). This software is very appropria...
| Main Author: | |
|---|---|
| Format: | Thesis |
| Language: | English English |
| Published: |
2015
|
| Subjects: | |
| Online Access: | http://eprints.uthm.edu.my/1319/ http://eprints.uthm.edu.my/1319/1/24p%20HIZAL%20ABU%20BAKAR.pdf http://eprints.uthm.edu.my/1319/2/HIZAL%20ABU%20BAKAR%20WATERMARK.pdf |
| _version_ | 1848887430855262208 |
|---|---|
| author | Abu Bakar, Hizal |
| author_facet | Abu Bakar, Hizal |
| author_sort | Abu Bakar, Hizal |
| building | UTHM Institutional Repository |
| collection | Online Access |
| description | This study presents the outcomes of the performance evaluation simulation residual voltage output resulting from lightning arrestors IEEE Recommended model. This simulation uses software Alternative Transient Program - Electromagnetic transients Programmed (ATP-EMTP). This software is very appropriate in examining the behavior of the system, especially a high voltage system lines. As a result of the comparison can be made in the system of 132kV transmission line between systems that are not supplied with lightning arrestors, system supplied with lightning arrestors with conventional styles and systems supplied with lightning arrestors IEEE Recommended model. The results of the simulation study comparisons can be made by taking into account the peak voltage at sub transient conditions. This situation can determine the 132kV transmission line system can protect the equipment properly. Selection lightning 10kA with the 8μs fast front surge and trailing the current time is 20μs is appropriate in the circumstances lightning eruption in Malaysia. In this research, 132kV transmission line parameter tower need to be enclosed by the actual value of the output to the accurate or almost accurate in determining the ability of a lightning arrester in the system. |
| first_indexed | 2025-11-15T19:54:16Z |
| format | Thesis |
| id | uthm-1319 |
| institution | Universiti Tun Hussein Onn Malaysia |
| institution_category | Local University |
| language | English English |
| last_indexed | 2025-11-15T19:54:16Z |
| publishDate | 2015 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | uthm-13192021-10-03T06:23:08Z http://eprints.uthm.edu.my/1319/ Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP) Abu Bakar, Hizal TK3001-3521 Distribution or transmission of electric power This study presents the outcomes of the performance evaluation simulation residual voltage output resulting from lightning arrestors IEEE Recommended model. This simulation uses software Alternative Transient Program - Electromagnetic transients Programmed (ATP-EMTP). This software is very appropriate in examining the behavior of the system, especially a high voltage system lines. As a result of the comparison can be made in the system of 132kV transmission line between systems that are not supplied with lightning arrestors, system supplied with lightning arrestors with conventional styles and systems supplied with lightning arrestors IEEE Recommended model. The results of the simulation study comparisons can be made by taking into account the peak voltage at sub transient conditions. This situation can determine the 132kV transmission line system can protect the equipment properly. Selection lightning 10kA with the 8μs fast front surge and trailing the current time is 20μs is appropriate in the circumstances lightning eruption in Malaysia. In this research, 132kV transmission line parameter tower need to be enclosed by the actual value of the output to the accurate or almost accurate in determining the ability of a lightning arrester in the system. 2015-01 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/1319/1/24p%20HIZAL%20ABU%20BAKAR.pdf text en http://eprints.uthm.edu.my/1319/2/HIZAL%20ABU%20BAKAR%20WATERMARK.pdf Abu Bakar, Hizal (2015) Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP). Masters thesis, Universiti Tun Hussein Onn Malaysia. |
| spellingShingle | TK3001-3521 Distribution or transmission of electric power Abu Bakar, Hizal Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP) |
| title | Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP) |
| title_full | Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP) |
| title_fullStr | Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP) |
| title_full_unstemmed | Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP) |
| title_short | Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP) |
| title_sort | fast transient simulation of ieee recommended surge arrester model on a transmission line using alternative transient program (atp) |
| topic | TK3001-3521 Distribution or transmission of electric power |
| url | http://eprints.uthm.edu.my/1319/ http://eprints.uthm.edu.my/1319/1/24p%20HIZAL%20ABU%20BAKAR.pdf http://eprints.uthm.edu.my/1319/2/HIZAL%20ABU%20BAKAR%20WATERMARK.pdf |