Development of fire protection duct for the safety-relevant circuits

Fire protection ducts store and protect electrical cables during a fire outbreak. The cables provide power supplies to the active fire protective system (e.g., water sprinklers, fire alarms) and extend the time for evacuation. Fire protection duct can be fabricated by combining and assembling fire-r...

Full description

Bibliographic Details
Main Author: Lim, You Yi
Format: Final Year Project / Dissertation / Thesis
Published: 2023
Subjects:
Online Access:http://eprints.utar.edu.my/5901/
http://eprints.utar.edu.my/5901/1/ME_1804285__YOU_YI_LIM.pdf
_version_ 1848886533307760640
author Lim, You Yi
author_facet Lim, You Yi
author_sort Lim, You Yi
building UTAR Institutional Repository
collection Online Access
description Fire protection ducts store and protect electrical cables during a fire outbreak. The cables provide power supplies to the active fire protective system (e.g., water sprinklers, fire alarms) and extend the time for evacuation. Fire protection duct can be fabricated by combining and assembling fire-retardant boards. The project scope focuses on formulating the water-based intumescent binder (WIB) as the fundamental of the fire-retardant board. W-IB was proven to have better properties than the commercial magnesium oxide (MgO) board, especially in fire resistivity. The commercial MgO board possesses a low resistivity to fire and water and is not able to provide long-term protection of the underlying substrate from a high temperature and moisture environment. In the analysis, four groups of W-IB were formulated and analysed through fire resistance testing (e.g., Bunsen burner test), chemical testing (e.g., static immersion test), mechanical testing (e.g., adhesion strength test), thermal testing (e.g., TGA test), and physical testing (e.g., SEM/EDX test, FTIR test). Next, WIB and vermiculite were combined to make fire-retardant board prototypes. To ascertain the compositions' best performance, a half-hour small-scale fire, a density measurement, a sound insulation, and a three-point flexural tests were conducted. The leading-performing fire-retardant board was then cast using the best-performing compositions. The capabilities of the fire-retardant board and the commercial MgO board were compared using a 1-hour small-scale fire test and density measurement test. The leading-performing fire-retardant board was then used to construct a small-scale fire protection duct. The results of all the tests revealed that, both pre and post of the 1-hour small-scale fire test, fireretardant board prototype 4 (P4) has a lower weight loss percentage than commercial MgO board. Prototype P4 has a weight loss of 20.6 % lower than commercial MgO board. Thus, prototype P4 has better suitability to construct fire protection duct. On the other hand, prototype P4 also showed a lower temperature profile (100 ℃) than the commercial MgO board (220 ℃) when conducting the 1-hour small-scale fire test. Therefore, prototype P4 possesses an effective W-IB that can resist the fire propagation and remain its technical integrity after a 1-hour small-scale fire test.
first_indexed 2025-11-15T19:40:00Z
format Final Year Project / Dissertation / Thesis
id utar-5901
institution Universiti Tunku Abdul Rahman
institution_category Local University
last_indexed 2025-11-15T19:40:00Z
publishDate 2023
recordtype eprints
repository_type Digital Repository
spelling utar-59012023-10-05T17:07:06Z Development of fire protection duct for the safety-relevant circuits Lim, You Yi TJ Mechanical engineering and machinery Fire protection ducts store and protect electrical cables during a fire outbreak. The cables provide power supplies to the active fire protective system (e.g., water sprinklers, fire alarms) and extend the time for evacuation. Fire protection duct can be fabricated by combining and assembling fire-retardant boards. The project scope focuses on formulating the water-based intumescent binder (WIB) as the fundamental of the fire-retardant board. W-IB was proven to have better properties than the commercial magnesium oxide (MgO) board, especially in fire resistivity. The commercial MgO board possesses a low resistivity to fire and water and is not able to provide long-term protection of the underlying substrate from a high temperature and moisture environment. In the analysis, four groups of W-IB were formulated and analysed through fire resistance testing (e.g., Bunsen burner test), chemical testing (e.g., static immersion test), mechanical testing (e.g., adhesion strength test), thermal testing (e.g., TGA test), and physical testing (e.g., SEM/EDX test, FTIR test). Next, WIB and vermiculite were combined to make fire-retardant board prototypes. To ascertain the compositions' best performance, a half-hour small-scale fire, a density measurement, a sound insulation, and a three-point flexural tests were conducted. The leading-performing fire-retardant board was then cast using the best-performing compositions. The capabilities of the fire-retardant board and the commercial MgO board were compared using a 1-hour small-scale fire test and density measurement test. The leading-performing fire-retardant board was then used to construct a small-scale fire protection duct. The results of all the tests revealed that, both pre and post of the 1-hour small-scale fire test, fireretardant board prototype 4 (P4) has a lower weight loss percentage than commercial MgO board. Prototype P4 has a weight loss of 20.6 % lower than commercial MgO board. Thus, prototype P4 has better suitability to construct fire protection duct. On the other hand, prototype P4 also showed a lower temperature profile (100 ℃) than the commercial MgO board (220 ℃) when conducting the 1-hour small-scale fire test. Therefore, prototype P4 possesses an effective W-IB that can resist the fire propagation and remain its technical integrity after a 1-hour small-scale fire test. 2023 Final Year Project / Dissertation / Thesis NonPeerReviewed application/pdf http://eprints.utar.edu.my/5901/1/ME_1804285__YOU_YI_LIM.pdf Lim, You Yi (2023) Development of fire protection duct for the safety-relevant circuits. Final Year Project, UTAR. http://eprints.utar.edu.my/5901/
spellingShingle TJ Mechanical engineering and machinery
Lim, You Yi
Development of fire protection duct for the safety-relevant circuits
title Development of fire protection duct for the safety-relevant circuits
title_full Development of fire protection duct for the safety-relevant circuits
title_fullStr Development of fire protection duct for the safety-relevant circuits
title_full_unstemmed Development of fire protection duct for the safety-relevant circuits
title_short Development of fire protection duct for the safety-relevant circuits
title_sort development of fire protection duct for the safety-relevant circuits
topic TJ Mechanical engineering and machinery
url http://eprints.utar.edu.my/5901/
http://eprints.utar.edu.my/5901/1/ME_1804285__YOU_YI_LIM.pdf